SDA 740Zi

4 GHz, 20 GS/s, 4ch, 20 Mpts/Ch SDA with 15.4" WXGA Color Display. 50 ohm and 1 Mohm Input. 40 GS/s and 40 Mpts/Ch in interleaved mode.


SDA 725Zi   (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
Analog Bandwidth @ 50 Ω (-3 dB)2.5 GHz
Input Channels4
Single-Shot Sample Rate/Ch40 GS/s on 2 Ch
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 40 M
SDA 735Zi   (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
Analog Bandwidth @ 50 Ω (-3 dB)3.5 GHz
Input Channels4
Single-Shot Sample Rate/Ch40 GS/s on 2 Ch
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 40 M
SDA 740Zi   (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
Analog Bandwidth @ 50 Ω (-3 dB)4 GHz
Input Channels4
Single-Shot Sample Rate/Ch40 GS/s on 2 Ch
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 40 M
SDA 760Zi   (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Quick Specs
Analog Bandwidth @ 50 Ω (-3 dB)6 GHz
Input Channels4
Single-Shot Sample Rate/Ch40 GS/s on 2 Ch
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 40 M
Check up to four models. Compare
Powerful SDA II Analysis Package
Unleash the power of serial data analysis to understand and characterize your design, prove compliance, and determine why a device or host fails compliance.

But how do you determine why a device fails compliance? LeCroy's SDA II serial data debug software is the most powerful and versatile solution for finding the root cause of serial data compliance failures. SDA II provides the confidence you need to ensure proper functionality.

While some solutions simply provide problem notifications, the SDA 7 Zi is the only oscilloscope that helps you identify the problem and and put your project back on schedule.

Versatile SDA II for Compliance and Debug
For compliance testing, LeCroy's QualiPHY compliance test suite provides the best available solutions to automate, configure and document standardized tests. However, when a design fails a compliance test, the engineer needs an advanced set of tools to identify and solve those problems. The LeCroy SDA 7 Zi includes a debugging toolset that provides insight into eye and jitter analysis. Armed with this insight, engineers can confidently drill down and identify the root cause. The Quick View of the SDA shows the Eye Diagram, TIE Track, Bathtub Curve, Jitter histogram, NQ-Scale and Jitter Spectrum. No other analyzer provides simultaneous interaction and real-time changes in all six measurements. LeCroy's X-Stream II Architecture provides fast updates and the fastest eye interpretation. The fastest eye building and the maximum unit intervals per second means the shortest time to reach a solution.

A high-speed serial trigger enables triggering on up to 2.7 GB/s serial patterns of up to 80-bits in length, allowing up to two 8b/10b primitives to be triggered on. Jitter calculations are based on statistics. With the most advanced long memory performance to 256 Mpts/Ch and X-Stream II enabled responsiveness, eye and jitter analysis occurs rapidly.

Automated Compliance Testing
QualiPHY compliance test suite provides easy to use step-by-step instructions for testing compliance on a wide array of serial data standards. Fast automated test operation, illustrated instructions, and connection diagrams simplify the process. Complete test reporting is provided along with a 'stop on fail' feature which begins the debug process.

Whether debugging eye pattern or other compliance test failures, the SDA 7 Zi Series has the accessible tools. Rapidly isolate the source of the problem in your design. Advanced usability like 8b/10b decode, mask violation locator, ISI plot, and equalization are easy to find. Provide cable characteristics and Cable De-embedding automatically adjusts for the cable effects. The result—true rise time and amplitudes in measurements. The SDA uses the same flexible math on math analysis which is valuable when understanding design behavior in the event of a compliance failure.

SDA II – Advanced Tools to Isolate and Analyze

Flow Diagram User Interface
Eye and Jitter Analysis in the SDA 7 Zi begins with a simple, interactive flow diagram user interface intuitively guiding the user through the setup of Eye Measurements, Jitter Measurements, or both at the same time.

Serial Trigger
The SDA 7 Zi Series comes standard with the 80-bit Pattern Trigger installed. The SDA 760Zi and SDA 740Zi include the High-speed Pattern Trigger option (up to 2.7 Gb/s), while the SDA 735Zi and SDA 725Zi pattern triggers up to 1.25 Gb/s. Both pattern triggers provide a recovered clock and data output on the front of the oscilloscope.

8b/10b Decoding
LeCroy's 8b/10b serial decode option with powerful search capability enables captured waveforms to be searched for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes.

Equalization
Equalization removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization.

ISI Plot
The ISI plot displays data dependent jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data dependent jitter without the need for a repeating bit pattern.

Jitter Spectrum
  • The jitter spectrum plot allows viewing of any periodic jitter
  • Peak annotation displays the frequencies directly on the spectrum
  • The LeCroy spectrum plot allows viewing of DDj removal for maximum understanding

Jitter Trend
  • Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
  • The jitter trend clearly shows any non-stationary jitter behavior

Histogram & Bathtub
  • Display of measured jitter histogram clearly shows any unusual jitter distributions such as bi-modal or non-Gaussian tails. By simply viewing the jitter breakdown (Rj, Dj), the raw data view shows jitter behavior that can be lost
  • This unprocessed display gives a high degree of confidence in the accuracy of the jitter breakdown and bathtub curve

Eye Patterns Show Mask Violations to the Bit
  • Eye pattern measurement on up to 8 million consecutive bits ensures that even transient jitter and noise events are captured
  • Consecutive bit eye pattern analysis allows for the measurement of the wave shapes of individual bits that violate the compliance mask (violation location)
  • The fastest UI accumulation and very low measurement jitter (typically 1 ps rms)

Cable De-embedding
Even expensive, high-performance cabling can have an adverse effect on measurements and steal margin from a design. Cable losses and slow rise times can lead to intersymbol interference that is induced by the measurement system but is not present in the design. The cable de-embedding feature removes these adverse effects leading to more accurate measurements.

Superior Eye Diagram Analysis

SDA II Advanced Debug for Eye and Jitter Analysis
LeCroy''s X-Stream II technology enables unprecedented speed in eye diagram creation. With a 15.3" high definition display and flexible landscape views, the SDA 7 Zi provides more insight into eyes than ever before. New features, such as IsoBER, add insight to the traditionally non-quantitative view of eye openings.

In addition, properly distinguishing between the random and deterministic jitter in a serial data signal is a crucial part of being able to reduce the overall jitter. For example, properly identifying frequencies at which periodic jitter is present is typically a common part of determining that jitter source. The SDA 7 Zi is the only analyzer that fully integrates jitter measurements into the oscilloscope software leading to greater confidence in jitter measurements.

Dual-Eye View Mode
Viewing the Transition and Non-Transition eye diagrams allows for analysis of de-emphasis in serial data waveforms. In addition, Dual-Eye Gated enables the creation of two separate eyes based on a separate signal input (i.e. Read/Write).
Mask Violation Locator
Mask failures are identified by contrasting color spots which appear anywhere the data intersects the mask template. Users can call up the actual stored bit stream waveform at the point in time of the initial failure. The actual bit sequence is also identified, pointing out any ISI problems. Instantly jump to the next violation, or any other within the stored pattern.
IsoBER
Mask testing is not always the best way to determine if the signal is going to meet Bit Error Rate requirements because it lacks quantitative analysis of vertical noise and jitter. LeCroy's unique IsoBER analysis tool provides this quantitative analysis by extrapolating the eye diagram data and displaying the lines of BER directly on the eye. This helps to quickly determine the minimum eye opening and also is instrumental in detecting cross-talk by analyzing the vertical eye closure. These measurements are not possible with standard eye diagram techniques.

More confidence in jitter Breakdown

Simplify Jitter Decomposition
The sources of jitter can be categorized as Deterministic or Random, which is an important distinction in calculating the Total Jitter (TJ) of a signal. There are cases where cross talk, or other types of deterministic jitter, can masquerade as random jitter and cause incorrect calculations.

LeCroy's integrated SDA II jitter analysis offers two decomposition algorithms to account for these situations, giving the user confidence that all jitter components are accurately recognized and processed correctly. The jitter decomposition calculates both methods simultaneously and alerts the user only when there is a deviation between the results, giving assurance that the correct jitter values are displayed.

Intuitive Jitter Breakdown Displays
LeCroy's SDA II Serial Data Analysis provides intuitive graphical views of jitter decomposition to quicken insight to the root cause.
To understand deterministic jitter values and their sources, SDA II provides the following tools:
  1. Periodic Jitter Spectrum identifies the sources contributing the highest values of Pj.
  2. ISI Plot isolates bit patterns that contribute the most Intersymbol Interference (ISI)
  3. DDJ Histogram provides a greater understanding of the distributionof Data Dependent Jitter (DDJ)

Setup Warning Indicators
Green / Yellow / Red setup warning indicators alert the user if there is something that requires their attention. For example, if the user's input signal is a clock and they have not selected clock as their signal type, a yellow indicator will be displayed informing the user that they have an inconsistency in the setup that may require their attention.

Vertical System

Analog Bandwidth @ 50 Ω (-3 dB) 4 GHz
Rise Time (typical) 105 ps
Input Channels 4
Bandwidth Limiters 20 MHz, 200 MHz
Input Impedance 50 Ω or 1 MΩ||15pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage 50 Ω (ProBus): ±5 Vrms
Channel-Channel Isolation ProLink Input > 200:1 up to 2 GHz, > 50:1 from 2 GHz to 4 GHz
Channel to Channel Isolation ProBus Input > 100:1 up to 2.5 GHz, > 30:1 from 2.5 GHz to 3.5 GHz
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity 50 Ω: 2 mV–1 V/div, fully variable (2-9.99 mV/div via zoom); 1 MΩ: 1 mV–10 V/div, fully variable
DC Gain Accuracy ±1.5% of full scale
Offset Range 50 Ω:
Offset Accuracy ±(1.5% of full scale + 1.0% of offset value + 1 mV)
 

Horizontal System

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range 20 ps/div–1000 s/div (RIS mode: 20 ps/div - 10 ns/div; Roll mode: up to 1000 s/div)
Clock Accuracy < 1 ppm
Jitter Noise Floor 750 fs (typical)
Trigger Jitter 1 psrms (typical)
Sample Rate and Delay Time Accuracy < 0.06 / SR + (1 ppm * Reading) (rms)
Channel-Channel Deskew Range ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input) 10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output) 10 MHz; 50 Ω impedance, output at the rear
External Sample Clock 0.1 Hz-100 MHz, 50 Ω or 1 MΩ impedance, applied at the auxiliary input
 

Acquisition System

Single-Shot Sample Rate/Ch 40 GS/s on 2 Ch
Random Interleaved Sampling (RIS) 200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time 1 μs
Standard Memory (4 Ch / 2 Ch) (Number of Segments) 20 M / 40 M
S - Memory Option 32 M / 64 M
M - Memory Option 64 M / 128 M
L - Memory Option 128 M / 256 M
 

Acquisition Modes

Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Modes Normal, Auto, Single, and Stop
Sources Any input channel, Aux, Aux/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode DC, AC, HFRej, LFRej
Pre-trigger Delay 0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range ±5 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs 2 div @ < 3.5 GHz
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs 2 div @ < 4 GHz
External Trigger Sensitivity 2 div @ < 1 GHz
External Trigger Input Range Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger 2.0 GHz @ = 10 mV/div
 

Basic Triggers

Edge/ Slope/ Line Triggers when signal meets slope (positive, negative, or either) and level condition.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
 

SMART Triggers

State or Edge Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
 

SMART Triggers with Exclusion Technology

Glitch Triggers on positive or negative glitches with widths selectable as low as 500 ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Width (Signal or Pattern) Triggers on positive or negative widths with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Interval (Signal or Pattern) Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified) Triggers on any source if a given state (or transition edge) has occurred on another source.
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
"A" Trigger List Edge, Window, Width, Glitch, Pattern, Pattern State, State, Dropout, Interval, Runt, Slew Rate, Serial Data (optional I2C, SPI, UART/RS-232, CAN, LIN, FlexRay)
"B" Trigger List Edge
Exclusion Triggering Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Holdoff Between Sequential Triggers Arming = Serial & Triggering = Anything, then min. time between events defined by serial pattern length
 

Cascade (Sequence) Triggering

Capability Arm on “A” event, then Trigger on “B” event. Or Arm on “A” event, then Qualify on “B” event, and Trigger on “C” event. Or Arm on “A” event, then Qualify on “B” then “C” event, and Trigger on “D” event
Types A or B event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog) C or D event: Edge or Pattern
Holdoff Delay between A and B, B and C, C and D, are all selectable by time or number of events
Reset Reset between A and B, B and C, C and D, are all selectable in time
 

High Speed Serial Protocol Triggering

Data Rates 100 Mb/s - 3.125 Gb/s
Pattern Length 80 bits, NRZ or 8b10b
Clock and Data Outputs 400mVp-p (typical) AC coupled
Clock Recovery Jitter 2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density (Typical)
Clock Recovery Tracking/ Acquisition Range 50 Mb/s - 2.7 Gb/s
Hardware Clock Recovery Loop BW PLL Loop BW = Fbaud/5500, 100 Mb/s to 1.25 Gb/s (Typical)
 

Low Speed Serial Protocol Triggering (Optional)

Optionally available I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay
 

Color Waveform Display

Type Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution WXGA; 1280 x 768 pixels
Number of traces Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity 256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels up to 4 simultaneously
Max Sampling Rate 40 GS/s (20 GS/s for WavePro 710Zi without WPZi-1GHZ-4X20GS option)
Waveforms up to 2500 Waveforms/ second
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe System: ProBus Probus (and ProLink on 4-6 GHz models). Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output 1kHz square wave, 1Vp-p (typical), output to probe hook
 

Analog Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection Activate persistence on all or any combination of traces
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
Persistence Types Select analog, color, or three-dimensional
Persistence Aging Select from 500 ms to infinity
 

Setup and Waveform Storage

Front Panel and Instrument Status Store to the internal hard drive or to a USB-connected peripheral device.
 

High Speed Digitizer Output (Option)

Type LeCroy LSIB
Transfer Rate Up to 325 MB/s (Typical)
Output Protocol PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol TCP/IP
Command Set Via Windows Automation, or via LeCroy Remote Command Set
 

Processor/CPU

Type Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory 4 GB standard, up to 8 GB optional
Operating System Microsoft Windows® Vista Business Edition (64-bit) with SP1
Oscilloscope Operating Software Entire instrument including any installed optional applications packages operates within a single (X-Stream) Windows application
Real Time Clock Date and time displayed with waveform an in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 4 Zoom and 8 Math/Zoom traces
 

Interface

Remote Control Via Windows Automation, or via LeCroy Remote Command Set
GPIB Supports IEEE – 488.2
LSIB Port (optional) Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB (Device) Type-B
Ethernet (LAN) Supports 10/100/1000 BaseT Ethernet interface (RJ45 port)
USB (Host) minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port 15-pin D-Type WXGA compatible to support customer-supplied external monitor. DVI connector to support LeCroy Zi-EXTDISP-15 additional touch screen display accessory. Includes support for extended desktop operation with optional LeCroy or other second monitor
Serial (RS-232) 2 standard
Peripheral Bus LeCroy LBUS standard
 

Auxiliary Input

Signal Types Select External Trigger
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
 

Auxiliary Output

Signal Types Select from calibrator, control signals or Off
Calibrator Signal 5 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals Trigger enabled, trigger out, pass/fail status
 

General

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Power Requirements

Voltage 100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption 850 W/850 VA
 

Environmental and Safety

Temperature (Operating) +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating) –20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.5 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Random Vibration (Non-Operating) 2.0 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Physical Dimensions

Dimensions (HWD) 14"H x 18.4"W x 11.4"D (355 x 467 x 289 mm)
Weight 39.5 lbs. (18 kg)
Shipping Weight 28.2 kg; 62 lbs.
 

Certifications

Certifications CE Compliant, UL and cUL listed; conforms to EN 61326-1, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
 

Memory Options

SDAZi-S-32
32 Mpt/Ch (64 Mpt/Ch Interleaved) Memory Option for SDA Zi. Includes an additional 2 GB of RAM (4 GB total)
SDAZi-M-64
64 Mpt/Ch (128 Mpt/Ch Interleaved) Memory Option for SDA Zi. Includes an additional 4 GB of RAM (8 GB total)
SDAZi-L-128
128 Mpt/Ch (256 Mpt/Ch Interleaved) Memory Option for SDA Zi

Computer Upgrade

WPZi-4-UPG-8GBRAM
Upgrade from 4 GB to 8 GB CPU RAM
GPIB-2
GPIB Option for LeCroy oscilloscope. Half-height card with custom connector.
WPZi-500GB-HD
Upgrade from standard size hard drive to 500 GB hard drive
WPZi-160GB-RHD-02
Additional 160 GB Hard Drive for WPZi. Includes Windows Vista OS, LeCroy oscilloscope software and critical scope operational file duplicates.
WPZi-500GB-RHD-02
Additional 500 GB Hard Drive for WPZi. Includes Windows Vista OS, LeCroy oscilloscope software and critical scope operational file duplicates.

Serial Data Analysis

WPZi-EYEDRII
Eye Doctor II Advanced Signal Integrity Tools for WavePro 7 Zi Oscilloscopes, SDA 7 Zi Serial Data Analyzers, and DDA 7 Zi Disk Drive Analyzers

Serial Data Compliance

QPHY-DDR2
QualiPHY DDR2 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3 Software Option
QPHY-ENET
QualiPHY Ethernet Application Software
QPHY-HDMI
QualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option)
QPHY-USB
USB Application Software Package
ENET-2ADA-BNCSMA
2 x BNC to SMA Adapter
ENET-2CAB-SMA018
2 x 18 inch SMA to SMA Cable
ENET-2CAB-SMA036
2 x 36 inch SMA to SMA Cable
TF-DSQ
Probe Deskew and Calibration Fixture
TF-ENET-B
10/100/1000Base-T Compliance Test Fixture
TF-ET
Telecom Adaptor Kit 100Ω, 120Ω, 75Ω
TF-HDMI-3.3V-QUADPAK
HDMI Pull-Up Terminator Quad Pack – for Use with the Efficere ET-HDMI-TPS-S Test Fixture
TF-SATA-C
SATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-SATA-C-Kit
SATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-USB-B
USB 2.0 Testing Compliance Test Fixture

Serial Trigger and Decode

WPZi-I2Cbus TD
I2C Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-SPIbus TD
SPI Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-UART-RS232bus TD
UART and RS232 Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-CANbus TD
CAN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-CANbus TDM
CAN Bus Trigger, Decode, and Measure Option for WavePro Zi Series Oscilloscopes
WPZi-FlexrayBus TD
FlexRay Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-FlexRayBus TDP
FlexRay Bus Trigger, Decode, and Physical Layer Test Option for WavePro Zi Series Oscilloscopes
WPZi-LINbus TD
LIN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-AudioBus TD
AudioBus Trigger and decode Option for WavePro 7Zi
WPZi-AudioBus TDG
AudioBus Trigger, decode, and Graph Option for WavePro 7Zi
WPZi-ProtoSync PE
Oscilloscope & PCIe Protocol Analyzer Synchronization Option
WPZi-ProtoSync PE-B
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option
WPZi-ProtoSync PE-B-ExtDisp
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option with Zi-EXTDISP-15 Display
WPZi-1553 TD
MIL-STD-1553 Trigger and decode option for WavePro Zi

High Speed Output Accessories

LSIB-1
High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector
LSIB-HOSTBOARD
PCI Express x4 Host Interface Board for desktop PC
LSIB-HOSTCARD
PCI Express x1 Express Card Host Interface for laptop Express Card slot
LSIB-CABLE-3M
PCI Express x 4 3-meter cable with x4 cable connectors included
LSIB-CABLE-7M
PCI Express x 4 7-meter cable with x4 cable connectors include

Mixed Signal Solutions

MS-500
500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option
MS-250
250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option

Mixed Signal Accessories

PK400-1
Large gripper probe set for 0.10'' (2.54 mm) pin pitch, includes 10 probes with color-coded leads
PK400-2
Medium gripper probe set for 0.04'' (1.0 mm) pin pitch, includes 10 probes with color-coded leads
PK400-3
Small gripper probe set for 0.008'' (0.2 mm) pin pitch, includes 10 probes with color-coded leads
MSO-MICTOR
Mictor Cable, D0-D35
MSO-3M
3M Interconnect Cable, D0-D17 or D18-D35

Other Software Options

WPZi-XDEV
Developer's Tool Kit Option for WavePro Zi Series
WPZi-SPECTRUM
Spectrum Analyzer and Advanced FFT Option for WavePro Zi Series
WPZi-EMC
EMC Pulse Parameter Software Package for WavePro Zi Series

Data Storage Software

WPZi-AORM
Advanced Optical Recording Measurement Package for WavePro Zi Series
WPZi-DDM2
Disk Drive Measurements Software Package for WavePro Zi Series

Power Analysis Software

WPZi-PMA2
Power Measure Analysis Software Package

Digital Filtering Software

WPZi-DFP2
Digital Filter Software Package for WavePro Zi Series

Miscellaneous

KYBD-1
Keyboard
WPZi-HARDCASE
Hard carrying case for all WavePro Zi Series oscilloscopes
WPZi-SOFTCASE
Soft carrying case for all WavePro Zi Series oscilloscopes
RACKMOUNT-1
Rack-mount accessory for converting a WavePro Zi series oscilloscope to an 8U rack-mounted package
ZI-EXTDISP-15
Top-mounted, Fully Integrated 15.3" WXGA with Touch Screen Display, Including all Cabling and Software
TTL-AUX-OUT
Accessory for Zi oscilloscopes to enable TTL level output from the Aux Out connector
Zi-FrontPanel-4Ch
Removable front panel with 4 independent channel controls for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500 Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000 Active Probes
ZS1500
1.5 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1000
1 GHz, 1 MΩ, 0.9 pF Active Probe
HFP2500
2.5 GHz Active Voltage Probe

Current Probes

CP030
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
AP015
30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse
CP150
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP500
500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak
DCS015
Deskew Calibration Source for AP015

Differential Amplifiers

DA1855A
DA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DXC100A
DXC100A, Selectable ÷100 or ÷10 , Passive Differential Probe Pair for DA18xxA series
DXC200
÷1,50 MHz low capacitance Passive Differential Probe Pair for DA18xxA series
DXC-5100
÷100 2.5KV Passive High Voltage Probe Pair for DA18xxA series. Requires DA101 for full performance
DA101
÷10 1MOhm Passive Attenuator for DXC series probes
DA1855A-PR2
2 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR2-RM
Rack mountable version of the DA1855A-PR2
DA1855A-RM
DA1855A with rackmount

Differential Probes

D620
WaveLink 6 GHz Differential probe module 5V
D610
WaveLink 6 GHz Differential probe module 2.5V
D320
WaveLink 3.5 GHz Differential probe module 5V
AP034
1 GHz Active Differential Probe
D310
WaveLink 3.5 GHz Differential probe module 2.5V
D600A-AT
WaveLink 7.5 GHz Differential Probe with Adjustable Tip Module
D500PT
WaveLink 6 GHz Differential Positioner Mounted Tip Module
WL-Pbus
WaveLink ProBus probe body = 3.5 GHz
AP033
500 MHz Active Differential Probe

High Voltage Probes

PPE1.2KV
10:1/100:1 200/300 MHz 5M Ohm/50M Ohm
PPE2KV
100:1 400 MHz 50M Ohm High Voltage Probe
PPE4KV
100:1 400 MHz 50M Ohm High-Voltage Probe
PPE5KV
100:1 400 MHz 50M Ohm High-Voltage Probe
PPE6KV
1000:1 400 MHz 50M Ohm High-Voltage Probe
PPE20KV
1000:1 100 MHz 100M Ohm High-Voltage Probe

High Voltage Differential Probes

AP031
15 MHz Differential Probe
ADP300
High-Voltage Active Differential Probe
ADP305
High-Voltage Differential Probes From LeCroy

Optical Probes

OE425
Short wavelength O/E Converter (500-870 nm)
OE455
Long wavelength O/E Converter (950-1630 nm)
OE525
Short wavelength O/E Converter (500-870 nm)
OE555
Long wavelength O/E converter

Probe Parts and Kits

LPA-SMA-KIT-A
Kit of Pro-Link to SMA Adapter, new style
LPA-SMA-A
Pro-Link to SMA Adapter, new style
D620-PT
WaveLink D620 6 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D610-PT
WaveLink D610 6 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D600ST
WaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP)
D350ST
WaveLink 4 GHz, 5 V Differential with Small Tip Module
D320-PT
WaveLink D320 3.5 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D310-PT
WaveLink D310 3.5 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D300A-AT
WaveLink 4 GHz Differential Probe with Adjustable Tip Module

Transmission Line Probes

PP066
7.5 GHz Low Capacitance ÷10/÷20 probe