WaveMaster 820Zi
20 GHz, 80 GS/s, 2 Ch, 20 Mpts/Ch WaveMaster with 15.3" WXGA Color Display. 50 ohm and 1 Mohm Input (16 GHz, 40 GS/s, 4 Ch, 10 Mpts/Ch)
WaveMaster 804Zi (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 806Zi (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 808Zi (8 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 813Zi (13 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 816Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 820Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 825Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate) WaveMaster 830Zi (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch
(80 GS/s on 2 Ch) Max Sample Rate)
 Innovative, Superior, Upgradeable LeCroy has broken bandwidth barriers by combining proven SiGe high-speed components with 5th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance: 30 GHz, 80 GS/s, and 512 Mpts/Ch Analysis Memory with superior signal fidelity. 5th Generation Digital Bandwidth Interleave (DBI) As memory and sample rate can be interleaved, so can bandwidth. Using high- performance microwave and RF technologies, and high-speed processors and digital signal processing (DSP), LeCroy intelligently operates high-speed analog components comfortably within their rated bandwidth range while providing twice the four channel bandwidth on two channels. This approach offers better signal fidelity compared to “stretching” of components beyond their rated bandwidth. See the Additional Resources for more information 4 channels @ 30 GHz with Zi-8CH-SYNCH more info  LeCroy has extended the power of it’s 30 GHz oscilloscope by providing a simple and fast method to combine two WaveMaster 830Zi oscilloscopes and provide 4 channels at 30 GHz. This solution is ideal for measurement and analysis of 28 to 56 Gb/s IQ modulated signals where ultra-high real-time bandwidth and four channels is required, or for capture and detailed analysis of other leading edge technologies [See Additional Resources for more information]. The solution is compatible with all WaveMaster 8 Zi models, so it may be used to create 20 to 30 GHz four channel oscilloscope captures, or 4 to 16 GHz eight channel oscilloscope captures. Superior Serial Data Analysis SDA II Serial Data Analysis Software provides the highest confidence for serial data testing. Eye diagram analysis provides 100x faster capture of unit intervals (UI) in the eye diagram, and is enhanced with superior eye diagram analysis tools, such as lines of constant bit error rate (IsoBER ) and mask violation locators. Superior jitter decomposition methodologies and analysis tools provides more ability to understand problem behaviors in serial data systems. X-Stream II architecture leverages the superior tools through 10–100x faster processing and complete analysis processing of full record lengths, providing more insight faster. Best Investment Protection From the perspective of bandwidth, sample rate, processing speed, responsiveness, display size, and range of capability, the WaveMaster 8 Zi platform is clearly superior and will remain so for many years to come. With the widest bandwidth upgrade range, an engineer who is working on 2nd generation technologies today can confidently know that WaveMaster 8 Zi will support 3rd or 4th generation technology needs several years from now. Most Advanced Oscilloscope Platform X-Stream II architecture provides 10–100x faster processing of long records, true 512 Mpts analysis memory, and instantaneous instrument responsiveness. When off-line data analysis is preferred, the LeCroy Serial Interface Bus (LSIB) provides up to 325 MB/s data transfer speeds. A 15.3" WXGA touchscreen display provides 50% more viewing area compared to other oscilloscopes in this class. Both 50 Ω and 1 MΩ inputs are standard on all oscilloscopes, as is support for all LeCroy probes(including passive probes) without the need for easy to lose external adapters or expensive power supplies.  Eye Doctor™ II Advanced Signal Integrity Tools Add Measurement Precision - Test Fixture and Cable De-embedding
- Emphasis Emulation
- Serial Data Channel Emulation
- Receiver Equalization
Add precision to signal integrity measurements by allowing the subtraction of fixture effects, and the emulation of emphasis, serial data channels, and receiver DFE, FFE, and CTLE equalization effects while at the same time maintaining fast oscilloscope processing speed on unlimited record lengths. Re-capture design margin, better understand actual circuit performance, and perform compliance testing on emerging high-speed standards, such as PCIe Gen3, USB 3.0, SAS/SATA 6 Gb/s, that require emulation to ensure high field reliability and interoperability. X-Stream II Architecture Optimized for Fast Throughput X-Stream II architecture enables high throughput of data—even when the oscilloscope is performing multiple 100 Mpts (or larger) waveforms. X-Stream II uses variable waveform segment lengths to enable all processing intensive calculations to take place in fast CPU cache memory, thus improving calculation speed and efficiency. The result—10–100x faster processing compared to other oscilloscopes.  Optimized for Long Memory X-Stream II essentially has no analysis memory length restrictions, regardless of analysis type, since the variable waveform segment length can always be limited to a size that can fit in CPU cache memory. Other oscilloscopes with conventional architectures cannot make this claim, and often have limitations on analysis memory of 5–20% the length of their acquisition memory under the best conditions. Optimized for Responsiveness By dynamically allocating buffers to maximize memory availability, the WaveMaster 8 Zi Series embodies the fastest front panel responsiveness. A built-in processing abort makes front panel control changes instant by stopping the current process and allowing new waveforms to be positioned or zoomed—all without a lengthy recalculation. Meanwhile, waveform previewing shows interim calculation results. Freedom from Probing Limitations WaveMaster 8 Zi excels in the way it offers general purpose utility never before seen in oscilloscopes from 4 to 30 GHz. All WaveMaster 8 Zi oscilloscopes contain selectable 50 Ω and 1 MΩ input capability and can be used with any LeCroy probe—passive or active—without requiring external adapters or power supplies.Use the two inputs per channel as a built-in switch matrix. Complete System Debug Understanding the relationships between different signals is vital to fast debug. Only WaveMaster 8 Zi combines the best of general purpose oscilloscopes (low-speed serial triggers and decoders, mixed signal capability, high impedance probing)with specialized 50 Ω inputs. This provides ability to 100% correlate high bandwidth signal activities or problems to low-speed events, such as low-speed serial data control words, power supply noise, or parallel data transmissions. Supported serial standards are 8b10b, PCIe, PCIe 2.0, SAS, SATA, XAUI, I2C, SPI CAN, LIN, UART-RS-232, and FlexRay. More Triggers Isolate More Problems More Effectively A full range of serial triggers (I2C, SPI, UART, RS-232, CAN, LIN, FlexRay) are available, providing capability to isolate events related to serial peripheral bus traffic. Most serial triggers contain powerful conditional DATA triggering to allow inclusion or exclusion of entire ranges of data values, which expedites understanding of how a range of serial bus traffic DATA values interact with other signals. TriggerScan™ TriggerScan uses high-speed hardware triggering capability with persistence displays to capture only the signals of interest and provide answers up to 100x faster than other methods.  WaveScan™ Advanced Search and Analysis Finds Problems that Triggers Won’t Find The best trigger won’t find all unusual events—a more powerful capability is sometimes needed. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search) or “scan” for an event in many acquisitions over a long period of time. Select from more than 20 search modes (frequency,rise time, runt, duty cycle, etc.), apply a search condition and begin scanning. When an event is found, WaveScan highlights the error on screen and displays a table listing the errors. Data Transfer Speeds 25–100x Faster LeCroy’s Serial Interface Bus (LSIB) option enables direct connection to the PCI Express® x4 high-speed data bus in the oscilloscope to enable data transfer rates up to 325 MB/s. All that is required is installation of an optional LSIB card in the oscilloscope and the corresponding host board (card) for desktop (laptop) PC in the remote computer. Data transfer is easily enabled through a supplied application program interface (API). Application Specific Solutions In addition to the general purpose WaveShape Analysis tools, application specific solutions are available for Serial Data Compliance, Embedded Design, Digital Design, and Automotive. These packages extend the LeCroy standard measurement and analysis capabilities and expand your oscilloscope’s utility as your needs change. - Digital Filter Software Package (WM8Zi-DFP2)
- Spectrum Analyzer Analysis Package (WM8Zi-SPECTRUM)
- Mixed Signal Oscilloscope Option (MS-250/MS-500)
- Jitter and Timing Analysis Package (WM8Zi-JTA2)
- Eye Doctor II – Advanced Signal Integrity Tools (WM8Zi-EYEDRII)
Vertical System | | Analog (2.92 mm Input) Bandwidth @ 50 Ω (-3 dB) | 20 GHz | | Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB) | 16 GHz (≥10 mV/div) | | Analog (ProBus Input) Bandwidth @ 50 Ω (-3 dB) | 3.5 GHz (≥10 mV/div) | | Analog (ProBus Input) Bandwidth @ 1 MΩ (-3 dB) | 500 MHz (typical, ≥2 mV/div) | | Rise Time (typical, 10-90%, 50 Ω) | 20 ps (@ full BW) (test limit, flatness mode) | | Rise Time (typical, 20-80%, 50 Ω) | 15 ps (flatness mode) | | Input Channels | 4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs), 3 (1 @ full BW, 2 with ProLink or ProBus inputs), or 2 (@ full BW) | | Bandwidth Limiters | For <20 GHz Mode: 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz, 13 GHz For ≥20 GHz Mode: None | | Input Impedance | 2.92mm Inputs: 50 Ω+/-2% for ≤79 mV/div, 50 Ω+/-3% for >79 mV/div ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe | | Input Coupling | 2.92 mm Inputs: 50 Ω: DC, GND
ProLink Inputs - 50 Ω: DC, GND
ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
| | Maximum Input Voltage | 2.92 mm Inputs: ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div 50 Ω (ProBus): ±5 Vmax, 3.5 Vrms 1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC) | | Channel-Channel Isolation | DC to 10 GHz: 50 dB (>315:1) 10 to 15 GHz: 46 dB (>200:1) 15 to 16 GHz: 40 dB (>100:1) 16 GHz to Max BW: 30 dB (>32:1) (For any two ProLink or 2.92mm input channels, same or different v/div settings, typical) | | Vertical Resolution | 8 bits; up to 11 bits with enhanced resolution (ERES) | | Sensitivity | 50 Ω (2.92 mm): 10 mV–500 mV/div, fully variable 50 Ω (ProLink): 2 mV–1 V/div, fully variable (2-9.9 mV/div via zoom) 50 Ω (ProBus): 2 mV–1 V/div, fully variable 1 MΩ (ProBus): 2 mV–10 V/div, fully variable | | DC Gain Accuracy | (±1.5% of full scale | | Offset Range | 50 Ω (2.92 mm): (±500 mV @ 2–79 mV/div (±4 V @ 80 mV/div -500 mV/div 50 Ω (ProLink): (±500 mV @ 2–100 mV/div (±4 V @ >100 mV/div -1 V/div 50 Ω (ProBus): (±750 mV @ 2–100 mV/div (±4 V @ >100 mV/div -1 V/div 1 MΩ: (±1V @ 2–128 mV/div (±10V @ 130mV-1.28V/div
(±100V @ 1.3V-10V/div | | Offset Accuracy | (±(1.5% of full scale + 1.5% of offset value + 2 mV) | | | Horizontal System | | Timebases | Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input | | Time/Division Range | For ≥20 GHz Mode: Real-Time Mode, 20 ps/div - 12.5μs/div, depending on memory length For <20 GHz Mode: 20 ps/div–128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div; Roll mode: 100 ms/div up to 128 s/div), depending on memory length | | Clock Accuracy | < 1 ppm + (aging of 0.5ppm/yr from last calibration) | | Time Interval Accuracy | < 0.06 / SR + (clock accuracy* Reading) (rms) | | Jitter Noise Floor | For Acq. Length ≤10μs: 265 fsrms (TIE, typical) For Acq. Length >10μs: 300 fsrms (TIE, typical) | | Trigger Jitter | 2 ps rms (typical) <0.1 ps rms (typical, software assisted) | | Channel-Channel Deskew Range | (±9 x time/div. setting or 25 ns max. (whichever is larger), each channel | | External Timebase Reference (Input) | 10 MHz; 50 Ω impedance, applied at the rear input | | External Timebase Reference (Output) | 10 MHz; 50 Ω impedance, output at the rear | | External Sample Clock | Not Available | | | Acquisition System | | Single-Shot Sample Rate/Ch | 40 GS/s on 4 Ch
(80 GS/s on 2 Ch when operated in ≥20 GHz Mode) | | Random Interleaved Sampling (RIS) | For ≥20 GHz Mode: Not Applicable For <20 GHz Mode: 200 GS/s for repetitive signals (20 ps/div to 10 ns/div) | | Maximum Trigger Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) | | Intersegment Time | 1 μs | | Standard Memory (4 Ch / 2 Ch) (Number of Segments) | 10 M / 10 M (20 Mpts in 2 Ch mode when operated in ≥20 GHz Mode) (5000) | | S - Memory Option | 32 M / 32 M 64 Mpts in 2 Ch mode when operated in ≥20 GHz Mode) (15,000) | | M - Memory Option | 64 M / 64 M (128 Mpts in 2 Ch mode when operated in ≥20 GHz Mode) (15,000) | | L - Memory Option | 128 M / 128 M (256 Mpts in 2 Ch mode when operated in ≥20 GHz Mode) (15,000) | | VL – Memory Option | 256 M / 256 M (512 Mpts in 2 Ch mode when operated in ≥20 GHz Mode) (15,000) | | | Acquisition Modes | | Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps | | Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution | | Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps | | Interpolation | Linear or Sin x/x | | | Triggering System | | Modes | Normal, Auto, Single, and Stop | | Sources | Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger) | | Coupling | DC, AC, HFRej, LFRej | | Pre-trigger Delay | 0–100% of memory size (adjustable in 1% increments of 100 ns) | | Post-trigger Delay | 0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode | | Hold-off by Time | From 2 ns up to 20 s or from 1 to 99,999,999 events | | Internal Trigger Range | (±4.1 div from center | | Trigger Sensitivity with Edge Trigger (Ch 1–4) 2.92mm Inputs | 3 div @ < 15 GHz 1.5 div @ < 3 GHz 1.0 div @ < 200 MHz (for DC coupling, ≥ 10 mV/div, 50 Ω ) | | Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs | 2 div @ < 3.5 GHz 1.5 div @ < 1.75 GHz 1.0 div @ < 200 MHz (for DC coupling, ≥ 10 mV/div, 50 Ω ) | | Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs | 3 div @ < 15 GHz 1.5 div @ < 3 GHz 1.0 div @ < 200 MHz (for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω ) | | External Trigger Sensitivity, (Edge Trigger) | 2 div @ < 1 GHz 1.5 div @ < 500 MHz 1.0 div @ < 200 MHz (for DC coupling) | | External Trigger Input Range | Aux (±0.4 V); Aux/10 (±4 V) | | Max. Trigger Frequency, SMART Trigger | 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps) | | | Basic Triggers | | Edge | Triggers when signal meets slope (positive, negative, or either) and level condition. | | Window | Triggers when signal exits a window defined by adjustable thresholds | | TV-Composite Video | Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative). | | | SMART Triggers | | State or Edge Qualified | Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events. | | Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. | | Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. | | Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
| | | SMART Triggers with Exclusion Technology | | Glitch | Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults. | | Width (Signal or Pattern) | Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults. | | Interval (Signal or Pattern) | Triggers on intervals selectable between 1 ns and 20 s. | | Timeout (State/Edge Qualified) | Triggers on any source if a given state (or transition edge) has occurred on another source.
Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events. | | Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns. | | Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns. | | Exclusion Triggering | Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met | | | Cascade (Sequence) Triggering | | Capability | Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event. Or Arm on “A” event, then Qualify on “B” then “C” event, and Trigger on “D” event | | Types | A, B, C, or D event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog) | | Holdoff | Holdoff between A and B, B and C, or both is selectable by time or number of events | | Reset | Reset between A and B, B and C, or both is selectable in time or number of events | | | High Speed Serial Protocol Triggering | | Data Rates | 100 Mb/s - 2.7 Gb/s, 3.0, 3.125 Gb/s | | Pattern Length | 80 bits, NRZ or 8b10b | | Clock and Data Outputs | 400mVp-p (typical) AC coupled | | Clock Recovery Jitter | 2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density (typical) | | Hardware Clock Recovery Loop BW | PLL Loop BW = Fbaud/5500, 100 Mb/s to 2.488 Gb/s (typical) | | | Low Speed Serial Protocol Triggering (Optional) | | Optionally available | I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay | | | Color Waveform Display | | Type | Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen | | Resolution | WXGA; 1280 x 768 pixels. | | Number of traces | Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces. | | Grid Styles | Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y | | Waveform Representation | Sample dots joined, or sample dots only | | | Internal Waveform Memory | | Internal Waveform Memory | 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity. | | | LeCroy WaveStream™ Fast Viewing Mode | | Intensity | 256 Intensity Levels, 1–100% adjustable via front panel control | | Types | Select analog or color-graded | | Number of Channels | up to 4 simultaneously | | Max Sampling Rate | 40 GS/s (80 GS/s when operated in ≥ 20 GHz Mode) | | Persistence Aging | Select from 500 ms to Infinity | | Waveforms/second (continuous) | up to 2500 Waveforms/second | | Operation | Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF | | | Automatic Setup | | Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals | | Find Vertical Scale | Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range | | | Probes | | Probes
| Qty. (2) ÷10 Passive Probes | | Probing System | Probus and ProLink. Automatically detects and supports a variety of compatible probes | | Scale Factors | Automatically or manually selected depending on probe used | | Calibration Output | 1kHz square wave, 1Vp-p (typical), output to probe hook | | | Integrated Second Display | | Type | Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen | | Resolution | WXGA; 1280 x 768 pixels | | | Analog Persistence Display | | Analog and Color-Graded Persistence | Variable saturation levels; stores each trace’s persistence data in memory | | Trace Selection | Activate persistence on all or any combination of traces | | Sweep Display Modes | All accumulated, or all accumulated with last trace highlighted | | Persistence Types | Select analog, color, or three-dimensional | | Persistence Aging | Select from 500 ms to infinity | | | High Speed Digitizer Output (Option) | | Type | LeCroy LSIB | | Transfer Rate | up to 325 MB/s (typical) | | Output Protocol | PCI Express, Gen 1 (4 lanes utilized for data transfer) | | Control Protocol | TCP/IP | | Command Set | Via Windows Automation, or via LeCroy Remote Command Set | | | Processor/CPU | | Type | Intel® CoreTM 2 Quad, 2.5 GHz (or better) | | Processor Memory | 4 GB standard, up to 8 GB optional (8 GB standard with "M-64", "L-128", or "VL-256" memory) | | Operating System | Microsoft Windows® Vista Business Edition (64-bit) with SP1 | | Real Time Clock | Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks. | | | Zoom Expansion Traces | | Zoom Expansion Traces | Display up to 4 Zoom and 8 Math/Zoom traces | | | Setup Storage | | Front Panel and Instrument Status | Store to the internal hard drive, over a network, or to a USB-connected peripheral device. | | | Interface | | Remote Control | Via Windows Automation, or via LeCroy Remote Command Set | | Network Communication Standard | VXI-11 or VICP, LXI Class C (v1.2) Compliant | | GPIB | Supports IEEE – 488.2 | | LSIB Port (optional) | Supports PCIe Gen1 x4 protocol with LeCroy supplied API | | Ethernet (LAN) | Supports 10/100/1000BaseT Ethernet interface (RJ45 port) | | USB (Host) | minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices | | External Monitor Port | 15 pin D-Type WXGA compatible to support customer-supplied external monitor. DVI connector to support LeCroy WPZi-EXTDISP-15 additional touch screen display accessory. Includes support for extended desktop operation with optional LeCroy or other second monitor. | | Peripheral Bus | LeCroy LBUS standard | | | Auxiliary Input | | Signal Types | Select External Trigger or External Clock Input on the front panel | | Coupling | 50 Ω: DC; 1 MΩ: AC, DC, GND | | Max. Input Voltage | 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC) | | | Auxiliary Output | | Connector Type | BNC, located on front | | Signal Types | Select from calibrator, control signals or Off | | Calibrator Signal | 500 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ) | | Control Signals | Trigger enabled, trigger out, pass/fail status, off | | | General | | Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. | | | Power Requirements | | Voltage | 100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection | | Max. Power Consumption | 1025 W / 1025 VA | | | Environmental and Safety | | Temperature (Operating) | +5 °C to +40 °C including CD-RW/DVD-ROM drive | | Temperature (Non-Operating) | –20 °C to +60 °C | | Humidity (Operating) | 5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C. | | Humidity (Non-Operating) | 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F | | Altitude (Operating) | Up to 10,000 ft. (3048 m) at or below +25 °C | | Altitude (Non-Operating) | Up to 40,000 ft. (12,192 m) | | Random Vibration (Operating) | 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes | | Random Vibration (Non-Operating) | 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes | | Functional Shock | 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total | | | Physical Dimensions | | Dimensions (HWD) | 14"H x 18.4"W x 15.3"D (355 x 467 x 390 mm) | | Weight | 58 lbs. (26.4 kg) | | Shipping Weight | 76.0 lbs. (34.5 kg) | | | Certifications | | Certifications | CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04 | | | Warranty and Service | | Warranty and Service | 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services. | | |
Memory Options | WM8Zi-S-32 32 Mpts/Ch Memory Option for WaveMaster 8 Zi. SDA 8 Zi, and DDA 8 Zi. Includes 4 GB RAM standard | WM8Zi-M-64 64 Mpts/Ch Memory Option for WaveMaster 8 Zi. SDA 8 Zi, and DDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total) | WM8Zi-L-128 128 Mpts/Ch Memory Option for WaveMaster 8 Zi. SDA 8 Zi, and DDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total) | WM8Zi-VL-256 256 Mpts/Ch Memory Option for WaveMaster 8 Zi. SDA 8 Zi, and DDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total) | Computer Upgrade | GPIB-2 GPIB Option for LeCroy oscilloscope. Half-height card with custom connector. | WM8Zi-4-UPG-8GBRAM Upgrade from 4 GB to 8 GB CPU RAM | WM8Zi-500GB-HD Upgrade from Standard Size Hard Drive to 500 GB Hard Drive | WM8Zi-160GB-RHD-02 Additional 160 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates | WM8Zi-500GB-RHD-02 Additional 500 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates | Serial Data Analysis | WM8Zi-SDAII SDA II Serial Data Analysis Option WM8Zi-SDAII (Standard on SDA 8 Zi and DDA 8 Zi) | WM8Zi-CBL-DE-EMBED Cable De-Embed Option (Standard on SDA 8 Zi and DDA 8 Zi) | WM8Zi-EYEDRII Eye Doctor II Advanced Signal Integrity Tools | Synchronize Oscilloscope Options | Zi-8CH-SYNCH HW Kit to allow combination of channels from two 8Zi oscilloscopes | Serial Data Compliance | QPHY-DDR2 QualiPHY DDR2 Compliance Software Option | QPHY-DDR3 QualiPHY Enabled DDR3 Software Option | QPHY-DisplayPort QualiPHY Enabled DisplayPort Software Option | QPHY-ENET QualiPHY Ethernet Application Software | QPHY-HDMI QualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option) | QPHY-PCIe QualiPHY Enabled PCIe Software Option (for Gen1 and Gen2 testing) | QPHY-SAS2 QualiPHY SAS2 Compliance Software | QPHY-SATA QualiPHY Enabled SATA Software Option | QPHY-USB USB Application Software Package | QPHY-USB3-Tx-Rx QualiPHY Enabled USB 3.0 Software Option | QPHY-UWB WiMedia UWB Transmitter Measurement Software Option | ENET-2ADA-BNCSMA 2 x BNC to SMA Adapter | ENET-2CAB-SMA018 2 x 18 inch SMA to SMA Cable | ENET-2CAB-SMA036 2 x 36 inch SMA to SMA Cable | WM8Zi-ET-PMT Electrical Telecom Mask Test Software Package | WM8Zi-SDM Serial Data Mask Software Package (Standard on SDA 8 Zi and DDA 8 Zi) | TF-DSQ Probe Deskew and Calibration Fixture | TF-ENET-B 10/100/1000Base-T Compliance Test Fixture | TF-ET Telecom Adaptor Kit 100Ω, 120Ω, 75Ω | TF-HDMI-3.3V-QUADPAK HDMI Pull-Up Terminator Quad Pack – for Use with the Efficere ET-HDMI-TPS-S Test Fixture | TF-SATA-C SATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required) | TF-SATA-C-Kit SATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required) | TF-USB-B USB 2.0 Testing Compliance Test Fixture | TF-USB3 USB 3.0 Test Fixture Set TF-USB3 ("A" male, "A" female, "B" female) | Serial Trigger and Decode | WM8Zi-HSPT 50 Mb/s to 3.125 Gb/s High-speed Serial Pattern Trigger Option for 4–30 GHz Oscilloscopes and Disk Drive Analyzers (Standard on SDA 8 Zi) | WM8Zi-8B10B D 8b10b Decode Option Standard on SDA 8 Zi and DDA 8 Zi) | WM8Zi-I2Cbus TD I2C Bus Trigger and Decode Option | WM8Zi-SPIbus TD SPI Bus Trigger and Decode Option | WM8Zi-LINbus TD LIN Trigger and Decode Option | WM8Zi-UART-RS232bus TD UART and RS-232 Trigger and Decode Option | WM8Zi-FlexRayBus TD FlexRay Trigger and Decode Option | WM8Zi-FlexRayBus TDP FlexRay Bus Trigger, Decode, and Physical Layer Test Option | WM8Zi-CANbus TDM CANbus TDM Trigger, Decode and Measure/Graph Option | WM8Zi-CANbus TD CANbus TD Trigger and Decode Option | WM8Zi-PCIEbus D PCI Express (Gen 1.x, 2.0, and 3.0) Protocol Link Layer Decode Annotation for WaveMaster 8 Zi Series Oscilloscopes and Analyzers | WM8Zi-AudioBus TD AudioBus Trigger and decode Option for WaveMaster 8Zi 7Zi | WM8Zi-AudioBus TDG AudioBus Trigger, decode, and Graph Option for WaveMaster 7Zi | WM8Zi-ProtoSync PE Oscilloscope & PCIe Protocol Analyzer Synchronization Option | WM8Zi-ProtoSync PE-B Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option | WM8Zi-ProtoSync PE-B-ExtDisp Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option with Zi-EXTDISP-15 Display | WM8Zi-1553 TD MIL-STD-1553 decode option for WaveMaster 8 Zi | High Speed Output Accessories | LSIB-1 High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector | LSIB-HOSTBOARD PCI Express x4 Host Interface Board for desktop PC | LSIB-HOSTCARD PCI Express x1 Express Card Host Interface for laptop Express Card slot | LSIB-CABLE-3M PCI Express x 4 3-meter cable with x4 cable connectors included | LSIB-CABLE-7M PCI Express x 4 7-meter cable with x4 cable connectors include | Mixed Signal Solutions | MS-500 500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option | MS-500-36 250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option | MS-250 250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option | Mixed Signal Accessories | PK400-1 Large gripper probe set for 0.10'' (2.54 mm) pin pitch, includes 10 probes with color-coded leads | PK400-2 Medium gripper probe set for 0.04'' (1.0 mm) pin pitch, includes 10 probes with color-coded leads | PK400-3 Small gripper probe set for 0.008'' (0.2 mm) pin pitch, includes 10 probes with color-coded leads | MSO-MICTOR Mictor Cable, D0-D35 | MSO-3M 3M Interconnect Cable, D0-D17 or D18-D35 | Jitter Analysis Software | WM8Zi-JTA2 Jitter Timing and Analysis Software Package (Standard on SDA8 Zi and DDA 8 Zi) | Other Software Options | WM8Zi-XDEV Advanced Customization Software Package | WM8Zi-SPECTRUM Spectrum Analyzer and Advanced FFT Option | WM8Zi-EMC EMC Pulse Parameter Software Package | Data Storage Software | WM8Zi-AORM Advanced Optical Recording Measurement Package | WM8Zi-DDM2 Disk Drive Measurements Software Package (Standard on DDA 8 Zi) | WM8Zi-DDA Disk Drive Analyzer Software Package | Power Analysis Software | WM8Zi-PMA2 Power Measure Analysis Software Package | Digital Filtering Software | WM8Zi-DFP2 Digital Filter Software Package | Miscellaneous | OC1024 OC1024 scope cart is sturdy and mobile | OC1021 OC1021 scope cart is sturdy and mobile | KYBD-1 Keyboard | ZI-EXTDISP-15 Top-mounted, Fully Integrated 15.3" WXGA with Touch Screen Display, Including all Cabling and Software | WM8Zi-HARDCASE Hard Carrying Case | WM8Zi-SOFTCASE Soft Carrying Case | WM8Zi-RACKMOUNT Rackmount Accessory for Converting aWM8Zi Series Oscilloscope to an 8U Rack-mounted Package | TTL-AUX-OUT Accessory for Zi oscilloscopes to enable TTL level output from the Aux Out connector | Zi-FrontPanel Removable front panel for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes | Zi-FrontPanel-4Ch Removable front panel with 4 independent channel controls for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes |
Current Probes | CP030 30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse | CP031 30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse | AP015 30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse | CP150 150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse | CP500 500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak | DCS015 Deskew Calibration Source for AP015 | Differential Amplifiers | DA1855A DA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters | DXC100A DXC100A, Selectable ÷100 or ÷10 , Passive Differential Probe Pair for DA18xxA series | DXC200 ÷1,50 MHz low capacitance Passive Differential Probe Pair for DA18xxA series | DXC-5100 ÷100 2.5KV Passive High Voltage Probe Pair for DA18xxA series. Requires DA101 for full performance | DA101 ÷10 1MOhm Passive Attenuator for DXC series probes | DA1855A-PR2 2 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters | DA1855A-PR2-RM Rack mountable version of the DA1855A-PR2 | DA1855A-RM DA1855A with rackmount | Differential Probes | D2505 WaveLink D2505 25 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2). | D2505-PS 25 GHz Complete Probe System with Solder-In Tip (25 GHz) and Positioner Tip Browser (22 GHz) | D2005 WaveLink D2005 20 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2). | D2005-PS 20 GHz Complete Probe System with Solder-In Tip (20 GHz) and Positioner Tip Browser (20 GHz) | D1605 WaveLink D1605 16 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2). | D1605-PS 16 GHz Complete Probe System with Solder-In Tip (16 GHz) and Positioner Tip Browser (16 GHz) | D1305 WaveLink D1305 13 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2). | D1305-PS 13 GHz Complete Probe System with Solder-In Tip (13 GHz) and Positioner Tip Browser (13 GHz) | Dxx05-PT-KIT WaveLink Dxx05-PT (22 GHz rating) Adjustable Positioner Tip Kit. For use with Dxx05 amplifiers. | WL-2.92MM WaveLink 2.92mm Platform/Cable Assembly Kit for >=20 GHz WaveLink Probes. | WL-PLink-A WaveLink ProLink Platform/Cable Assembly Kit for >=13 GHz WaveLink Probes. | LPA-2.92 ProLink to 2.92mm Adapter with Probe Power and Communication Pass Through | D620 WaveLink 6 GHz Differential probe module 5V | D610 WaveLink 6 GHz Differential probe module 2.5V | D320 WaveLink 3.5 GHz Differential probe module 5V | AP034 1 GHz Active Differential Probe | D310 WaveLink 3.5 GHz Differential probe module 2.5V | Dx10-PT-KIT WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets(Qty 2). | Dx20-PT-KIT WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D600A-AT WaveLink 7.5 GHz Differential Probe with Adjustable Tip Module | D500PT WaveLink 6 GHz Differential Positioner Mounted Tip Module | WL-PLink WaveLink ProLink probe body >3.5 GHz | WL-Pbus WaveLink ProBus probe body = 3.5 GHz | AP033 500 MHz Active Differential Probe | DA18000AC 18 GHz Type “K” Differential Probe, AC Coupled | D13000PS 13 GHz Differential Probe System | D11000PS 11 GHz Differential Probe System | High Voltage Probes | PPE1.2KV 10:1/100:1 200/300 MHz 5M Ohm/50M Ohm | PPE2KV 100:1 400 MHz 50M Ohm High Voltage Probe | PPE4KV 100:1 400 MHz 50M Ohm High-Voltage Probe | PPE5KV 100:1 400 MHz 50M Ohm High-Voltage Probe | PPE6KV 1000:1 400 MHz 50M Ohm High-Voltage Probe | PPE20KV 1000:1 100 MHz 100M Ohm High-Voltage Probe | High Voltage Differential Probes | AP031 15 MHz Differential Probe | ADP300 High-Voltage Active Differential Probe | ADP305 High-Voltage Differential Probes From LeCroy | Optical Probes | OE425 Short wavelength O/E Converter (500-870 nm) | OE455 Long wavelength O/E Converter (950-1630 nm) | OE525 Short wavelength O/E Converter (500-870 nm) | OE555 Long wavelength O/E converter | Probe Parts and Kits | LPA-SMA-KIT-A Kit of Pro-Link to SMA Adapter, new style | LPA-SMA-A Pro-Link to SMA Adapter, new style | LPA-K-KIT-A Kit of ProLink to K/2.92 mm Adapters | LPA-K-A ProLink to K/2.92 mm Adapter | DXX05-SI Replacement Dxx05-SI 13-25 GHz Solder-In Lead with Qty. 10 Spare Resistors. For warranted accuracy, amplifier must be returned to factory for calibration with this lead. | DXX05-PT Replacement Dxx05-PT Positioner Tip | Dx20-SP Replacement Square Pin lead set for D320/D620 | Dx20-SI Replacement Solder tip lead set for D320/D620 | Dx20-QC Replacement Quick Connect lead set for D320/D620 | Dx20-PT Replacement Dx20-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets | Dx10-SP Replacement Square Pin lead set for D310/D610 | Dx10-SI Replacement Solder tip lead set for D310/D610 | Dx10-PT Replacement Dx10-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets | D620-PT WaveLink D620 6 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D610-PT WaveLink D610 6 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D600ST WaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP) | D350ST WaveLink 4 GHz, 5 V Differential with Small Tip Module | D320-PT WaveLink D320 3.5 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D310-PT WaveLink D310 3.5 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D300A-AT WaveLink 4 GHz Differential Probe with Adjustable Tip Module | D13000SI Replacement Solder-In Interconnect Lead | D11000SI Replacement solder-in interconnect lead | Transmission Line Probes | PP066 7.5 GHz Low Capacitance ÷10/÷20 probe |
|
|
|