SDA 820Zi

20 GHz, 80 GS/s, 2 Ch, 40 Mpts/Ch Serial Data Analyzer with 15.3"WXGA Color Display. 50 ohm and 1 Mohm Input (16 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch)


SDA 804Zi   (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)4 GHz
(≥10 mV/div)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(Memory and Sample Rate can be doubled in 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(5000)
SDA 806Zi   (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)6 GHz
(≥10 mV/div)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(Memory and Sample Rate can be doubled in 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(5000)
SDA 808Zi   (8 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)8 GHz
(≥10 mV/div)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(Memory and Sample Rate can be doubled in 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(5000)
SDA 813Zi   (13 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)13 GHz
(≥10 mV/div)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(Memory and Sample Rate can be doubled in 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(5000)
SDA 816Zi   (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)16 GHz
(≥10 mV/div)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(Memory and Sample Rate can be doubled in 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(5000)
SDA 820Zi   (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)16 GHz
(≥10 mV/div)
Input Channels4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs),
3 (1 @ full BW, 2 with ProLink or ProBus inputs), or
2 (@ full BW)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ≥20 GHz Mode)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(20 Mpts in 2 Ch mode when operated in Digital Bandwidth Interleave mode)
(5000)
SDA 825Zi   (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)16 GHz
(≥10 mV/div)
Input Channels4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs),
3 (1 @ full BW, 2 with ProLink or ProBus inputs), or
2 (@ full BW)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ≥20 GHz Mode)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(20 Mpts in 2 Ch mode when operated in Digital Bandwidth Interleave mode)
(5000)
SDA 830Zi   (16 GHz Bandwidth, 4 Input Channels, 40 GS/s on 4 Ch (80 GS/s on 2 Ch) Max Sample Rate)
Quick Specs
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB)16 GHz
(≥10 mV/div)
Input Channels4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs),
3 (1 @ full BW, 2 with ProLink or ProBus inputs), or
2 (@ full BW)
Single-Shot Sample Rate/Ch40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ≥20 GHz Mode)
Standard Memory (4 Ch / 2 Ch) (Number of Segments)20 M / 20 M
(20 Mpts in 2 Ch mode when operated in Digital Bandwidth Interleave mode)
(5000)
Check up to four models. Compare
A Total Solution for Serial Data Analysis

Unleash the power of serial data analysis for understanding and characterizing your design, proving compliance and understanding why a device or host fails compliance. The Quad Summary View of the SDA II software always shows the eye, TIE, bathtub curve and jitter histogram. No other Serial Data Analyzer lets you see the simultaneous interaction and real-time changes in all four views. The X-Stream II Architecture provides fast updates and the fastest eye interpretation. Combined with up to 512 Mpts record lengths and more complete jitter decomposition tools, SDA II provides the fastest and most complete understanding of why serial data fails a compliance test.

Advanced jitter decomposition methodologies and tools provide more information about root cause. Eye Doctor II Advanced Signal Integrity Tools provide more measurement precision through the use of de-embedding and emulation of cables, fixtures, emphasis, serial data channels, and receivers. All jitter decomposition analysis functions can be zoomed and time correlated to specific serial data or other events, making root cause determination faster and easier.

Automated Compliance Testing

The QualiPHY compliance test suite provides step-by-step instructions for testing compliance on a wide array of serial data standards. The process is simplified with fast, automated test operations, illustrated instructions, connection diagrams, and stop on fail feature. Complete test reporting is also provided.

 

 

SDA II – Advanced Tools to Isolate and Analyze

Flow Diagram User Interface

Eye and jitter analysis in the SDA 8 Zi begins with a simple, interactive flow diagram intuitively guides you through the setup of Eye Measurements, ­Jitter Measurements, or both at the same time.

Serial Trigger

The SDA 8 Zi Series comes standard with the 80-bit Pattern Trigger installed. The serial trigger operates up to 3.125 Gb/s and supports both 8b10b and NRZ signals, and also includes a recovered clock and data output on the front of the oscilloscope.

8b/10b Decoding

The LeCroy’s 8b/10b serial decode ­option has powerful search capabilities enabling captured waveform searches for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes. User selection is provided for PCIe, PCIe 2.0, SAS, SATA, XAUI, generic 8b10b or user-defined 8b10b protocols.

Equalization

The equalization feature removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization.

ISI Plot

The ISI plot shows data-dependent ­jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data ­­­dependent jitter (DDj) eliminating the need for a repeating bit pattern.

Jitter Spectrum
  • The jitter spectrum plot allows viewing of any periodic jitter
  • Peak annotation displays the frequencies directly on the spectrum
  • The LeCroy spectrum plot allows viewing of DDj removal for maximum comprehension
Jitter Trend
  • Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
  • The jitter trend clearly shows any non-stationary jitter seems implied by the preceding jitter trend behavior
Histogram & Bathtub
  • Measured jitter histogram clearly displays unusual jitter distributions like ­bi-modal or non-Gaussian tails. The raw data view shows possibly lost jitter ­behavior just by viewing the jitter ­decomposition
  • This unprocessed display gives a high degree of confidence in the accuracy of the jitter decomposition and bathtub curve
Cable De-embedding

Even expensive, high-performance cabling can have an adverse effect on measurements and decrease ­margin from a design. Cable losses and slow rise times can lead to intersymbol interference (ISI). The cable de-embedding feature ­removes these adverse effects providing more accurate measurements.

Vertical System

Analog (2.92 mm Input) Bandwidth @ 50 Ω (-3 dB) 20 GHz
Analog (ProLink Input) Bandwidth @ 50 Ω (-3 dB) 16 GHz
(≥10 mV/div)
Analog (ProBus Input) Bandwidth @ 50 Ω (-3 dB) 3.5 GHz
(≥10 mV/div)
Analog (ProBus Input) Bandwidth @ 1 MΩ (-3 dB) 500 MHz (typical, ≥2 mV/div)
Rise Time (typical, 10-90%, 50 Ω) 20 ps (@ full BW)
(test limit, flatness mode)
Rise Time (typical, 20-80%, 50 Ω) 15 ps
(flatness mode)
Input Channels 4 (Any combination of 16 GHz ProLink inputs or 3.5 GHz ProBus inputs),
3 (1 @ full BW, 2 with ProLink or ProBus inputs), or
2 (@ full BW)
Bandwidth Limiters For <20 GHz Mode: 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz, 13 GHz
For ≥20 GHz Mode: None
Input Impedance 2.92mm Inputs: 50 Ω+/-2% for ≤79 mV/div, 50 Ω+/-3% for >79 mV/div
ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div
ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling 2.92 mm Inputs: ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProBus): ±5 Vmax, 3.5 Vrms
1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
Maximum Input Voltage 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProBus): ±5 Vmax, 3.5 Vrms
1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
Channel-Channel Isolation DC to 10 GHz: 50 dB (>315:1)
10 to 15 GHz: 46 dB (>200:1)
15 to 16 GHz: 40 dB (>100:1)
16 GHz to Max BW: 30 dB (>32:1)
(For any two ProLink or 2.92mm input channels, same or different v/div settings, typical)
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity 50 Ω (2.92 mm): 10 mV–500 mV/div, fully variable
50 Ω (ProLink): 2 mV–1 V/div, fully variable (2-9.9 mV/div via zoom)
50 Ω (ProBus): 2 mV–1 V/div, fully variable
1 MΩ (ProBus): 2 mV–10 V/div, fully variable
DC Gain Accuracy (±1.5% of full scale
Offset Range 50 Ω (2.92 mm):
(±500 mV @ 2–79 mV/div
(±4 V @ 80 mV/div -500 mV/div
50 Ω (ProLink):
(±500 mV @ 2–100 mV/div
(±4 V @ >100 mV/div -1 V/div
50 Ω (ProBus):
(±750 mV @ 2–100 mV/div
(±4 V @ >100 mV/div -1 V/div
1 MΩ:
(±1V @ 2–128 mV/div
(±10V @ 130mV-1.28V/div (±100V @ 1.3V-10V/div
Offset Accuracy (±(1.5% of full scale + 1.5% of offset value + 2 mV)
 

Horizontal System

Timebases Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range For ≥20 GHz Mode: Real-Time Mode, 20 ps/div - 12.5μs/div, depending on memory length
For <20 GHz Mode: 20 ps/div–128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div; Roll mode: 100 ms/div up to 128 s/div), depending on memory length
Clock Accuracy < 1 ppm + (aging of 0.5ppm/yr from last calibration)
Time Interval Accuracy < 0.06 / SR + (clock accuracy* Reading) (rms)
Jitter Noise Floor For Acq. Length ≤10μs: 265 fsrms (TIE, typical)
For Acq. Length >10μs: 300 fsrms (TIE, typical)
Trigger Jitter 2 ps rms (typical)
<0.1 ps rms (typical, software assisted)
Channel-Channel Deskew Range (±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
External Timebase Reference (Input) 10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output) 10 MHz; 50 Ω impedance, output at the rear
External Sample Clock Not Available
 

Acquisition System

Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch when operated in ≥20 GHz Mode)
Random Interleaved Sampling (RIS) For ≥20 GHz Mode: Not Applicable
For <20 GHz Mode: 200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time 1 μs
Standard Memory (4 Ch / 2 Ch) (Number of Segments) 20 M / 20 M
(20 Mpts in 2 Ch mode when operated in Digital Bandwidth Interleave mode)
(5000)
S - Memory Option 32 M / 32 M
64 Mpts in 2 Ch mode when operated in ≥20 GHz Mode)
(15,000)
M - Memory Option 64 M / 64 M
(128 Mpts in 2 Ch mode when operated in ≥20 GHz Mode)
(15,000)
L - Memory Option 128 M / 128 M
(256 Mpts in 2 Ch mode when operated in ≥20 GHz Mode)
(15,000)
VL – Memory Option 256 M / 256 M
(512 Mpts in 2 Ch mode when operated in ≥20 GHz Mode)
(15,000)
 

Acquisition Modes

Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Modes Normal, Auto, Single, and Stop
Sources Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range (±4.1 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) 2.92mm Inputs 3 div @ < 15 GHz
1.5 div @ < 3 GHz
1.0 div @ < 200 MHz
(for DC coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs 2 div @ < 3.5 GHz
1.5 div @ < 1.75 GHz
1.0 div @ < 200 MHz
(for DC coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs 3 div @ < 15 GHz
1.5 div @ < 3 GHz
1.0 div @ < 200 MHz
(for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω )
External Trigger Sensitivity, (Edge Trigger) 2 div @ < 1 GHz
1.5 div @ < 500 MHz
1.0 div @ < 200 MHz
(for DC coupling)
External Trigger Input Range Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
 

Basic Triggers

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Window Triggers when signal exits a window defined by adjustable thresholds
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
 

SMART Triggers

State or Edge Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events.
Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
 

SMART Triggers with Exclusion Technology

Glitch Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Width (Signal or Pattern) Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Interval (Signal or Pattern) Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified) Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Exclusion Triggering Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
 

Cascade (Sequence) Triggering

Capability Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event. Or Arm on “A” event, then Qualify on “B” then “C” event, and Trigger on “D” event
Types A, B, C, or D event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog)
Holdoff Holdoff between A and B, B and C, or both is selectable by time or number of events
Reset Reset between A and B, B and C, or both is selectable in time or number of events
 

High Speed Serial Protocol Triggering

Data Rates 100 Mb/s - 2.7 Gb/s, 3.0, 3.125 Gb/s
Pattern Length 80 bits, NRZ or 8b10b
Clock and Data Outputs 400mVp-p (typical) AC coupled
Clock Recovery Jitter 2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density (typical)
Hardware Clock Recovery Loop BW PLL Loop BW = Fbaud/5500, 100 Mb/s to 2.488 Gb/s (typical)
 

Low Speed Serial Protocol Triggering (Optional)

Optionally available I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay
 

Color Waveform Display

Type Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution WXGA; 1280 x 768 pixels.
Number of traces Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Internal Waveform Memory

Internal Waveform Memory 4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity 256 Intensity Levels, 1–100% adjustable via front panel control
Types Select analog or color-graded
Number of Channels up to 4 simultaneously
Max Sampling Rate 40 GS/s (80 GS/s when operated in ≥ 20 GHz Mode)
Persistence Aging Select from 500 ms to Infinity
Waveforms/second (continuous) up to 2500 Waveforms/second
Operation Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probing System Probus and ProLink. Automatically detects and supports a variety of compatible probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output 1kHz square wave, 1Vp-p (typical), output to probe hook
 

Integrated Second Display

Type Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution WXGA; 1280 x 768 pixels
 

Analog Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection Activate persistence on all or any combination of traces
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
Persistence Types Select analog, color, or three-dimensional
Persistence Aging Select from 500 ms to infinity
 

High Speed Digitizer Output (Option)

Type LeCroy LSIB
Transfer Rate up to 325 MB/s (typical)
Output Protocol PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol TCP/IP
Command Set Via Windows Automation, or via LeCroy Remote Command Set
 

Processor/CPU

Type Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory 4 GB standard, up to 8 GB optional
(8 GB standard with "M-64", "L-128", or "VL-256" memory)
Operating System Microsoft Windows® Vista Business Edition (64-bit) with SP1
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 4 Zoom and 8 Math/Zoom traces
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over a network, or to a USB-connected peripheral device.
 

Interface

Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
GPIB Supports IEEE – 488.2
LSIB Port (optional) Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB (Device) 0
Ethernet (LAN) Supports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB (Host) minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port 15 pin D-Type WXGA compatible to support customer-supplied external monitor.
DVI connector to support LeCroy WPZi-EXTDISP-15 additional touch screen display accessory.
Includes support for extended desktop operation with optional LeCroy or other second monitor.
Peripheral Bus LeCroy LBUS standard
 

Auxiliary Input

Signal Types Select External Trigger or External Clock Input on the front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
 

Auxiliary Output

Connector Type BNC, located on front
Signal Types Select from calibrator, control signals or Off
Calibrator Signal 500 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals Trigger enabled, trigger out, pass/fail status, off
 

General

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Power Requirements

Voltage 100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption 1025 W / 1025 VA
 

Environmental and Safety

Temperature (Operating) +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating) –20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Physical Dimensions

Dimensions (HWD) 14"H x 18.4"W x 15.3"D (355 x 467 x 390 mm)
Weight 58 lbs. (26.4 kg)
Shipping Weight 76.0 lbs. (34.5 kg)
 

Certifications

Certifications CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services.
 

Memory Options

SDA8Zi-S-32
32 Mpts/Ch Memory Option for SDA 8 Zi, Includes 4 GB RAM standard
SDA8Zi-M-64
64 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)
SDA8Zi-L-128
128 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)
SDA8Zi-VL-256
256 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)

Computer Upgrade

GPIB-2
GPIB Option for LeCroy oscilloscope. Half-height card with custom connector.
WM8Zi-4-UPG-8GBRAM
Upgrade from 4 GB to 8 GB CPU RAM
WM8Zi-500GB-HD
Upgrade from Standard Size Hard Drive to 500 GB Hard Drive
WM8Zi-160GB-RHD-02
Additional 160 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates
WM8Zi-500GB-RHD-02
Additional 500 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates

Serial Data Analysis

WM8Zi-EYEDRII
Eye Doctor II Advanced Signal Integrity Tools

Synchronize Oscilloscope Options

Zi-8CH-SYNCH
HW Kit to allow combination of channels from two 8Zi oscilloscopes

Serial Data Compliance

QPHY-DDR2
QualiPHY DDR2 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3 Software Option
QPHY-DisplayPort
QualiPHY Enabled DisplayPort Software Option
QPHY-ENET
QualiPHY Ethernet Application Software
QPHY-HDMI
QualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option)
QPHY-PCIe
QualiPHY Enabled PCIe Software Option (for Gen1 and Gen2 testing)
QPHY-SAS2
QualiPHY SAS2 Compliance Software
QPHY-SATA
QualiPHY Enabled SATA Software Option
QPHY-USB
USB Application Software Package
QPHY-USB3-Tx-Rx
QualiPHY Enabled USB 3.0 Software Option
QPHY-UWB
WiMedia UWB Transmitter Measurement Software Option
ENET-2ADA-BNCSMA
2 x BNC to SMA Adapter
ENET-2CAB-SMA018
2 x 18 inch SMA to SMA Cable
ENET-2CAB-SMA036
2 x 36 inch SMA to SMA Cable
TF-DSQ
Probe Deskew and Calibration Fixture
TF-ENET-B
10/100/1000Base-T Compliance Test Fixture
TF-ET
Telecom Adaptor Kit 100Ω, 120Ω, 75Ω
TF-HDMI-3.3V-QUADPAK
HDMI Pull-Up Terminator Quad Pack – for Use with the Efficere ET-HDMI-TPS-S Test Fixture
TF-SATA-C
SATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-SATA-C-Kit
SATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-USB-B
USB 2.0 Testing Compliance Test Fixture
TF-USB3
USB 3.0 Test Fixture Set TF-USB3 ("A" male, "A" female, "B" female)

Serial Trigger and Decode

WM8Zi-I2Cbus TD
I2C Bus Trigger and Decode Option
WM8Zi-SPIbus TD
SPI Bus Trigger and Decode Option
WM8Zi-LINbus TD
LIN Trigger and Decode Option
WM8Zi-UART-RS232bus TD
UART and RS-232 Trigger and Decode Option
WM8Zi-FlexRayBus TD
FlexRay Trigger and Decode Option
WM8Zi-FlexRayBus TDP
FlexRay Bus Trigger, Decode, and Physical Layer Test Option
WM8Zi-CANbus TDM
CANbus TDM Trigger, Decode and Measure/Graph Option
WM8Zi-CANbus TD
CANbus TD Trigger and Decode Option
WM8Zi-PCIEbus D
PCI Express (Gen 1.x, 2.0, and 3.0) Protocol Link Layer Decode Annotation for WaveMaster 8 Zi Series Oscilloscopes and Analyzers
WM8Zi-AudioBus TD
AudioBus Trigger and decode Option for WaveMaster 8Zi 7Zi
WM8Zi-AudioBus TDG
AudioBus Trigger, decode, and Graph Option for WaveMaster 7Zi
WM8Zi-ProtoSync PE
Oscilloscope & PCIe Protocol Analyzer Synchronization Option
WM8Zi-ProtoSync PE-B
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option
WM8Zi-ProtoSync PE-B-ExtDisp
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option with Zi-EXTDISP-15 Display
WM8Zi-1553 TD
MIL-STD-1553 decode option for WaveMaster 8 Zi

High Speed Output Accessories

LSIB-1
High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector
LSIB-HOSTBOARD
PCI Express x4 Host Interface Board for desktop PC
LSIB-HOSTCARD
PCI Express x1 Express Card Host Interface for laptop Express Card slot
LSIB-CABLE-3M
PCI Express x 4 3-meter cable with x4 cable connectors included
LSIB-CABLE-7M
PCI Express x 4 7-meter cable with x4 cable connectors include

Mixed Signal Solutions

MS-500
500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option
MS-250
250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option

Mixed Signal Accessories

MSO-MICTOR
Mictor Cable, D0-D35

Other Software Options

WM8Zi-XDEV
Advanced Customization Software Package
WM8Zi-SPECTRUM
Spectrum Analyzer and Advanced FFT Option
WM8Zi-EMC
EMC Pulse Parameter Software Package

Data Storage Software

WM8Zi-AORM
Advanced Optical Recording Measurement Package
WM8Zi-DDM2
Disk Drive Measurements Software Package (Standard on DDA 8 Zi)
WM8Zi-DDA
Disk Drive Analyzer Software Package

Power Analysis Software

WM8Zi-PMA2
Power Measure Analysis Software Package

Digital Filtering Software

WM8Zi-DFP2
Digital Filter Software Package

Miscellaneous

OC1024
OC1024 scope cart is sturdy and mobile
OC1021
OC1021 scope cart is sturdy and mobile
KYBD-1
Keyboard
ZI-EXTDISP-15
Top-mounted, Fully Integrated 15.3" WXGA with Touch Screen Display, Including all Cabling and Software
WM8Zi-HARDCASE
Hard Carrying Case
WM8Zi-SOFTCASE
Soft Carrying Case
WM8Zi-RACKMOUNT
Rackmount Accessory for Converting aWM8Zi Series Oscilloscope to an 8U Rack-mounted Package
TTL-AUX-OUT
Accessory for Zi oscilloscopes to enable TTL level output from the Aux Out connector
Zi-FrontPanel
Removable front panel for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes
Zi-FrontPanel-4Ch
Removable front panel with 4 independent channel controls for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500 Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000 Active Probes
ZS1500
1.5 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1000
1 GHz, 1 MΩ, 0.9 pF Active Probe
HFP2500
2.5 GHz Active Voltage Probe

Current Probes

CP030
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
AP015
30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse
CP150
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP500
500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak
DCS015
Deskew Calibration Source for AP015

Differential Amplifiers

DA1855A
DA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DXC100A
DXC100A, Selectable ÷100 or ÷10 , Passive Differential Probe Pair for DA18xxA series
DXC200
÷1,50 MHz low capacitance Passive Differential Probe Pair for DA18xxA series
DXC-5100
÷100 2.5KV Passive High Voltage Probe Pair for DA18xxA series. Requires DA101 for full performance
DA101
÷10 1MOhm Passive Attenuator for DXC series probes
DA1855A-PR2
2 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR2-RM
Rack mountable version of the DA1855A-PR2
DA1855A-RM
DA1855A with rackmount

Differential Probes

D2505
WaveLink D2505 25 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D2505-PS
25 GHz Complete Probe System with Solder-In Tip (25 GHz) and Positioner Tip Browser (22 GHz)
D2005
WaveLink D2005 20 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D2005-PS
20 GHz Complete Probe System with Solder-In Tip (20 GHz) and Positioner Tip Browser (20 GHz)
D1605
WaveLink D1605 16 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D1605-PS
16 GHz Complete Probe System with Solder-In Tip (16 GHz) and Positioner Tip Browser (16 GHz)
D1305
WaveLink D1305 13 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D1305-PS
13 GHz Complete Probe System with Solder-In Tip (13 GHz) and Positioner Tip Browser (13 GHz)
Dxx05-PT-KIT
WaveLink Dxx05-PT (22 GHz rating) Adjustable Positioner Tip Kit. For use with Dxx05 amplifiers.
WL-2.92MM
WaveLink 2.92mm Platform/Cable Assembly Kit for >=20 GHz WaveLink Probes.
WL-PLink-A
WaveLink ProLink Platform/Cable Assembly Kit for >=13 GHz WaveLink Probes.
LPA-2.92
ProLink to 2.92mm Adapter with Probe Power and Communication Pass Through
D620
WaveLink 6 GHz Differential probe module 5V
D610
WaveLink 6 GHz Differential probe module 2.5V
D320
WaveLink 3.5 GHz Differential probe module 5V
AP034
1 GHz Active Differential Probe
D310
WaveLink 3.5 GHz Differential probe module 2.5V
Dx10-PT-KIT
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets(Qty 2).
Dx20-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D600A-AT
WaveLink 7.5 GHz Differential Probe with Adjustable Tip Module
D500PT
WaveLink 6 GHz Differential Positioner Mounted Tip Module
WL-PLink
WaveLink ProLink probe body >3.5 GHz
WL-Pbus
WaveLink ProBus probe body = 3.5 GHz
AP033
500 MHz Active Differential Probe
DA18000AC
18 GHz Type “K” Differential Probe, AC Coupled
D13000PS
13 GHz Differential Probe System
D11000PS
11 GHz Differential Probe System

High Voltage Probes

PPE1.2KV
10:1/100:1 200/300 MHz 5M Ohm/50M Ohm
PPE2KV
100:1 400 MHz 50M Ohm High Voltage Probe
PPE4KV
100:1 400 MHz 50M Ohm High-Voltage Probe
PPE5KV
100:1 400 MHz 50M Ohm High-Voltage Probe
PPE6KV
1000:1 400 MHz 50M Ohm High-Voltage Probe
PPE20KV
1000:1 100 MHz 100M Ohm High-Voltage Probe

High Voltage Differential Probes

AP031
15 MHz Differential Probe
ADP300
High-Voltage Active Differential Probe
ADP305
High-Voltage Differential Probes From LeCroy

Optical Probes

OE425
Short wavelength O/E Converter (500-870 nm)
OE455
Long wavelength O/E Converter (950-1630 nm)
OE525
Short wavelength O/E Converter (500-870 nm)
OE555
Long wavelength O/E converter

Probe Parts and Kits

LPA-SMA-KIT-A
Kit of Pro-Link to SMA Adapter, new style
LPA-SMA-A
Pro-Link to SMA Adapter, new style
LPA-K-KIT-A
Kit of ProLink to K/2.92 mm Adapters
LPA-K-A
ProLink to K/2.92 mm Adapter
DXX05-SI
Replacement Dxx05-SI 13-25 GHz Solder-In Lead with Qty. 10 Spare Resistors. For warranted accuracy, amplifier must be returned to factory for calibration with this lead.
DXX05-PT
Replacement Dxx05-PT Positioner Tip
Dx20-SP
Replacement Square Pin lead set for D320/D620
Dx20-SI
Replacement Solder tip lead set for D320/D620
Dx20-QC
Replacement Quick Connect lead set for D320/D620
Dx20-PT
Replacement Dx20-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
Dx10-SP
Replacement Square Pin lead set for D310/D610
Dx10-SI
Replacement Solder tip lead set for D310/D610
Dx10-PT
Replacement Dx10-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
D620-PT
WaveLink D620 6 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D610-PT
WaveLink D610 6 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D600ST
WaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP)
D350ST
WaveLink 4 GHz, 5 V Differential with Small Tip Module
D320-PT
WaveLink D320 3.5 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D310-PT
WaveLink D310 3.5 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
D300A-AT
WaveLink 4 GHz Differential Probe with Adjustable Tip Module
D13000SI
Replacement Solder-In Interconnect Lead
D11000SI
Replacement solder-in interconnect lead

Transmission Line Probes

PP066
7.5 GHz Low Capacitance ÷10/÷20 probe