SDA 8 Zi Serial Data Analyzers

SDA 8 Zi Serial Data Analyzers are based on the WaveMaster 8 Zi Series oscilloscope and are equipped with double the standard memory to capture more unit intervals in the eye diagram. They include an enhanced high-speed serial pattern trigger that operates on up to 80 bit patterns and at speeds up to 3.125 Gb/s. Whether debugging eye pattern or other compliance test failures, the SDA 8 Zi Series rapidly isolates the source of the problem in your design.

Explore SDA 8 Zi Explore SDA 8 Zi
SDA 804Zi   
 
SDA 806Zi   
 
SDA 808Zi   
 
SDA 813Zi   
 
SDA 816Zi   
 
SDA 820Zi   
 
SDA 825Zi   
 
SDA 830Zi   
 
Check up to four models. Compare
A Total Solution for Serial Data Analysis

Unleash the power of serial data analysis for understanding and characterizing your design, proving compliance and understanding why a device or host fails compliance. The Quad Summary View of the SDA II software always shows the eye, TIE, bathtub curve and jitter histogram. No other Serial Data Analyzer lets you see the simultaneous interaction and real-time changes in all four views. The X-Stream II Architecture provides fast updates and the fastest eye interpretation. Combined with up to 512 Mpts record lengths and more complete jitter decomposition tools, SDA II provides the fastest and most complete understanding of why serial data fails a compliance test.

Advanced jitter decomposition methodologies and tools provide more information about root cause. Eye Doctor II Advanced Signal Integrity Tools provide more measurement precision through the use of de-embedding and emulation of cables, fixtures, emphasis, serial data channels, and receivers. All jitter decomposition analysis functions can be zoomed and time correlated to specific serial data or other events, making root cause determination faster and easier.

Automated Compliance Testing

The QualiPHY compliance test suite provides step-by-step instructions for testing compliance on a wide array of serial data standards. The process is simplified with fast, automated test operations, illustrated instructions, connection diagrams, and stop on fail feature. Complete test reporting is also provided.

 

 

SDA II – Advanced Tools to Isolate and Analyze

Flow Diagram User Interface

Eye and jitter analysis in the SDA 8 Zi begins with a simple, interactive flow diagram intuitively guides you through the setup of Eye Measurements, ­Jitter Measurements, or both at the same time.

Serial Trigger

The SDA 8 Zi Series comes standard with the 80-bit Pattern Trigger installed. The serial trigger operates up to 3.125 Gb/s and supports both 8b10b and NRZ signals, and also includes a recovered clock and data output on the front of the oscilloscope.

8b/10b Decoding

The LeCroy’s 8b/10b serial decode ­option has powerful search capabilities enabling captured waveform searches for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes. User selection is provided for PCIe, PCIe 2.0, SAS, SATA, XAUI, generic 8b10b or user-defined 8b10b protocols.

Equalization

The equalization feature removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization.

ISI Plot

The ISI plot shows data-dependent ­jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data ­­­dependent jitter (DDj) eliminating the need for a repeating bit pattern.

Jitter Spectrum
  • The jitter spectrum plot allows viewing of any periodic jitter
  • Peak annotation displays the frequencies directly on the spectrum
  • The LeCroy spectrum plot allows viewing of DDj removal for maximum comprehension
Jitter Trend
  • Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
  • The jitter trend clearly shows any non-stationary jitter seems implied by the preceding jitter trend behavior
Histogram & Bathtub
  • Measured jitter histogram clearly displays unusual jitter distributions like ­bi-modal or non-Gaussian tails. The raw data view shows possibly lost jitter ­behavior just by viewing the jitter ­decomposition
  • This unprocessed display gives a high degree of confidence in the accuracy of the jitter decomposition and bathtub curve
Cable De-embedding

Even expensive, high-performance cabling can have an adverse effect on measurements and decrease ­margin from a design. Cable losses and slow rise times can lead to intersymbol interference (ISI). The cable de-embedding feature ­removes these adverse effects providing more accurate measurements.

Main Specifications

Bandwidth 4 - 30 GHz
Starting from $75,490
Standard Memory 20 Mpts/ch
Max Memory 512 Mpts/ch
Max Sampling Rate 80 GS/s
 

Memory Options

SDA8Zi-S-32
32 Mpts/Ch Memory Option for SDA 8 Zi, Includes 4 GB RAM standard
SDA8Zi-M-64
64 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)
SDA8Zi-L-128
128 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)
SDA8Zi-VL-256
256 Mpts/Ch Memory Option for SDA 8 Zi. Includes an additional 4 GB of RAM (8 GB total)

Sampling Rate Options

WM8Zi-2X80GS
80 GS/s on 2 Ch Sampling Rate Option for WaveMaster 8 Zi (not available for 820Zi, 825Zi or 830Zi).Includes two separate external interleaving devices with storage case.

Computer Upgrade

GPIB-2
GPIB Option for LeCroy oscilloscope. Half-height card with custom connector.
WM8Zi-4-UPG-8GBRAM
Upgrade from 4 GB to 8 GB CPU RAM
WM8Zi-500GB-HD
Upgrade from Standard Size Hard Drive to 500 GB Hard Drive
WM8Zi-160GB-RHD-02
Additional 160 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates
WM8Zi-500GB-RHD-02
Additional 500 GB Hard Drive. Includes Windows Vista OS, LeCroy Oscilloscope Software and Critical Scope Operational File Duplicates

Serial Data Analysis

WM8Zi-EYEDRII
Eye Doctor II Advanced Signal Integrity Tools

Synchronize Oscilloscope Options

Zi-8CH-SYNCH
HW Kit to allow combination of channels from two 8Zi oscilloscopes

Serial Data Compliance

QPHY-DDR2
QualiPHY DDR2 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3 Software Option
QPHY-DisplayPort
QualiPHY Enabled DisplayPort Software Option
QPHY-ENET
QualiPHY Ethernet Application Software
QPHY-HDMI
QualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option)
QPHY-PCIe
PCIe Gen1 Compliance and Development Software
QPHY-SAS2
QualiPHY SAS2 Compliance Software
QPHY-SATA
QualiPHY Enabled SATA Software Option
QPHY-USB
USB Application Software Package
QPHY-USB3-Tx-Rx
QualiPHY Enabled USB 3.0 Software Option
QPHY-UWB
WiMedia UWB Transmitter Measurement Software Option
SDA-HDMI
HDMI Compliance Test Software Package for 4 GHz or higher SDA/WaveMaster Family of Digital Storage Oscilloscopes
TF-DSQ
Probe Deskew and Calibration Fixture
TF-ENET-B
10/100/1000Base-T Compliance Test Fixture
TF-ET
Telecom Adaptor Kit 100Ω, 120Ω, 75Ω
TF-SATA-C
SATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-SATA-C-Kit
SATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-USB-B
USB 2.0 Testing Compliance Test Fixture
TF-USB3
USB 3.0 Test Fixture Set TF-USB3 ("A" male, "A" female, "B" female)

Serial Trigger and Decode

WM8Zi-I2Cbus TD
I2C Bus Trigger and Decode Option
WM8Zi-SPIbus TD
SPI Bus Trigger and Decode Option
WM8Zi-LINbus TD
LIN Trigger and Decode Option
WM8Zi-UART-RS232bus TD
UART and RS-232 Trigger and Decode Option
WM8Zi-FlexRayBus TD
FlexRay Trigger and Decode Option
WM8Zi-FlexRayBus TDP
FlexRay Bus Trigger, Decode, and Physical Layer Test Option
WM8Zi-CANbus TDM
CANbus TDM Trigger, Decode and Measure/Graph Option
WM8Zi-CANbus TD
CANbus TD Trigger and Decode Option
WM8Zi-PCIEbus D
PCI Express (Gen 1.x, 2.0, and 3.0) Protocol Link Layer Decode Annotation for WaveMaster 8 Zi Series Oscilloscopes and Analyzers
WM8Zi-AudioBus TD
AudioBus Trigger and decode Option for WaveMaster 8Zi 7Zi
WM8Zi-AudioBus TDG
AudioBus Trigger, decode, and Graph Option for WaveMaster 7Zi
WM8Zi-ProtoSync PE
Oscilloscope & PCIe Protocol Analyzer Synchronization Option
WM8Zi-ProtoSync PE-B
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option
WM8Zi-ProtoSync PE-B-ExtDisp
Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option with Zi-EXTDISP-15 Display
WM8Zi-1553 TD
MIL-STD-1553 decode option for WavePro 7000

High Speed Output Accessories

LSIB-1
High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector
LSIB-HOSTBOARD
PCI Express x4 Host Interface Board for desktop PC
LSIB-HOSTCARD
PCI Express x1 Express Card Host Interface for laptop Express Card slot
LSIB-CABLE-3M
PCI Express x 4 3-meter cable with x4 cable connectors included
LSIB-CABLE-7M
PCI Express x 4 7-meter cable with x4 cable connectors include

Mixed Signal Solutions

MS-500
500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36
250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option
MS-250
250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option

Mixed Signal Accessories

MSO-MICTOR
Mictor Cable, D0-D35
MSO-DLS-18
Digital Lead Set, D0-D17
MSO-DLS-36
Digital Lead Set, D18-D35
MSO-GND-LEAD
MSO Flying Ground Lead
MSO-GND-EXTEND
MSO Ground Extenders
MSO-MICTOR-SHROUD
Shroud for Mictor Connector, Kit of 3
MSO-LBUS
LeCroy Bus Cable

Other Software Options

WM8Zi-XDEV
Advanced Customization Software Package
WM8Zi-SPECTRUM
Spectrum Analyzer and Advanced FFT Option
WM8Zi-EMC
EMC Pulse Parameter Software Package

Data Storage Software

WM8Zi-AORM
Advanced Optical Recording Measurement Package
WM8Zi-DDM2
Disk Drive Measurements Software Package (Standard on DDA 8 Zi)
WM8Zi-DDA
Disk Drive Analyzer Software Package

Power Analysis Software

WM8Zi-PMA2
Power Measure Analysis Software Package

Digital Filtering Software

WM8Zi-DFP2
Digital Filter Software Package

Miscellaneous

OC1024
OC1024 scope cart is sturdy and mobile
OC1021
OC1021 scope cart is sturdy and mobile
KYBD-1
Keyboard
FRONT-COVER-1
Replacement Protective Front Cover for WavePro Zi Series
ZI-EXTDISP-15
Top-mounted, Fully Integrated 15.3" WXGA with Touch Screen Display, Including all Cabling and Software
WM8Zi-HARDCASE
Hard Carrying Case
WM8Zi-SOFTCASE
Soft Carrying Case
WM8Zi-RACKMOUNT
Rackmount Accessory for Converting aWM8Zi Series Oscilloscope to an 8U Rack-mounted Package
TTL-AUX-OUT
Accessory for Zi oscilloscopes to enable TTL level output from the Aux Out connector
Zi-FrontPanel
Removable front panel for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes
Zi-FrontPanel-4Ch
Removable front panel with 4 independent channel controls for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes

Features

TriggerScan
TriggerScan
X-Stream II
X-Stream II

Active Voltage Probes

ZS1500-QUADPAK
Set of 4 ZS1500 Active Probes
ZS1000-QUADPAK
Set of 4 ZS1000 Active Probes
ZS1500
1.5 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1000
1 GHz, 1 MΩ, 0.9 pF Active Probe
HFP2500
2.5 GHz Active Voltage Probe

Current Probes

CP030
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
AP015
30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse
CP150
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP500
500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak

Differential Amplifiers

DA1855A
DA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR2
2 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR2-RM
Rack mountable version of the DA1855A-PR2
DA18000
18 GHz Differential Amplifier (SDA 18000 only)
DA1855A-RM
DA1855A with rackmount

Differential Probes

D2505
WaveLink D2505 25 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D2005
WaveLink D2005 20 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D1605
WaveLink D1605 16 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
D1305
WaveLink D1305 13 GHz/1.6Vp-p Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2).
WL-PLink-A
WaveLink ProLink Platform/Cable Assembly Kit for >=13 GHz WaveLink Probes.
WL-2.92MM
WaveLink 2.92mm Platform/Cable Assembly Kit for >=20 GHz WaveLink Probes.
DA18000AC
18 GHz Type “K” Differential Probe, AC Coupled
D13000PS
13 GHz Differential Probe System
D11000PS
11 GHz Differential Probe System
WL-Pbus
WaveLink ProBus probe body = 3.5 GHz
WL-PLink
WaveLink ProLink probe body >3.5 GHz
D500PT
WaveLink 6 GHz Differential Positioner Mounted Tip Module
D600A-AT
WaveLink 7.5 GHz Differential Probe with Adjustable Tip Module
D310
WaveLink 3.5 GHz Differential probe module 2.5V
D610
WaveLink 6 GHz Differential probe module 2.5V
D320
WaveLink 3.5 GHz Differential probe module 5V
D620
WaveLink 6 GHz Differential probe module 5V
AP033
500 MHz Active Differential Probe
AP034
1 GHz Active Differential Probe

High Voltage Probes

PPE1.2KV
10:1/100:1 200/300 MHz 5M Ohm/100M Ohm
PPE20KV
1000:1 100 MHz 100M Ohm High-Voltage Probe
PPE2KV
100:1 400 MHz 100M Ohm High Voltage Probe
PPE4KV
100:1 400 MHz 100M Ohm High-Voltage Probe
PPE5KV
100:1 400 MHz 100M Ohm High-Voltage Probe
PPE6KV
1000:1 400 MHz 5M Ohm High-Voltage Probe

High Voltage Differential Probes

AP031
15 MHz Differential Probe
ADP300
High-Voltage Active Differential Probe
ADP305
High-Voltage Differential Probes From LeCroy

Optical Probes

OE425
Short wavelength O/E Converter (500-870 nm)
OE455
Long wavelength O/E Converter (950-1630 nm)
OE525
Short wavelength O/E Converter (500-870 nm)
OE555
Long wavelength O/E converter

Passive Probes

PP007-WR-1
Passive Probe, 500 MHz, 2.5mm tip
PP011-1
PP011 Passive Probe

Probe Parts and Kits

LPA-SMA-A
Pro-Link to SMA Adapter, new style
LPA-SMA-KIT-A
Kit of Pro-Link to SMA Adapter, new style
LPA-K-A
ProLink to K/2.92 mm Adapter
LPA-K-KIT-A
Kit of ProLink to K/2.92 mm Adapters
DXX05-SI-RESISTORS
Replacement SI Resistor Kit for Dxx05-SI Solder-In Tip
D1X05-SI
Replacement D1x05-SI 13-16 GHz Solder-In Lead with Qty. 10 Spare Resistors. For warranted accuracy, amplifier must be returned to factory for calibration with this lead.
Dx10-SI
Replacement Solder tip lead set for D310/D610
D2005-SI
Replacement D2005-SI 20 GHz Solder-In Lead with Qty. 10 Spare Resistors. For warranted accuracy, amplifier must be returned to factory for calibration with this lead.
Dx10-SP
Replacement Square Pin lead set for D310/D610
Dx20-QC
Replacement Quick Connect lead set for D320/D620
D13000SI
Replacement Solder-In Interconnect Lead
Dx20-SI
Replacement Solder tip lead set for D320/D620
D13000SMP
Replacement SMP Interconnect Cables
Dx20-SP
Replacement Square Pin lead set for D320/D620
D13000SMA
Replacement SMA Interconnect Cables
D11000SI
Replacement solder-in interconnect lead
D11000SMP
SMP Interconnect Leads
D11000SMA
Replacement SMA Interconnect Cables
D600ST
WaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP)
D350ST
WaveLink 4 GHz, 5 V Differential with Small Tip Module
D300A-AT
WaveLink 4 GHz Differential Probe with Adjustable Tip Module
Dx10-PT
Replacement Dx10-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
Dx20-PT
Replacement Dx20-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
Dx10-PT-KIT
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets(Qty 2).
Dx20-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).