DA 1855A
 
DA1855.jpg (15700 bytes)

Leading Features

  • 100ns Overdrive Recovery

  • DC to 100 MHz Bandwidth

  • 100,000 to 1 CMRR

  • Gain 1 or 10

  • Very Low Noise

The DA1855A is a stand-alone, high-performance 100 MHz differential amplifier. It is intended to act as a signal conditioning preamplifier for oscilloscopes, digitizers and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. When used with a DA1855A, oscilloscopes can obtain Common Mode Rejection Ratio (CMRR) and overdrive recovery performance levels previously unobtainable.

Amplifier gain can be set to 1 or 10. A built-in input attenuator can be separately set to attenuate signals by a factor of 10, providing gains of 10, 1, or 0.1 and common mode dynamic range of 15.5 V (1) or 155 V (10). Optional probes increase the maximum input signal and common mode ranges in proportion to their attenuation ratio but do not exceed their maximum input voltage rating. Effective gain of the DA1855A, including probe attenuation, amplifier gain and attenuator settings, is automatically displayed.

The DA1855A has a bandwidth of 100 MHz, but any one of the three 3-pole bandwidth limit filters can be selected to reduce bandwidth to
20 MHz, 1 MHz or 100 kHz to limit noise above the frequency of interest.

The DA1855A output is carefully limited to 500 mV, so that the oscilloscope is not overdriven by large inputs. This allows many oscilloscopes to directly measure the settling of D/A converters with 14-bit (60 ppm) precision, better than any other differential comparator.

The DA1855A features a built-in Precision Voltage Generator (PVG) that can be set to any voltage between 15.5 volts (10 volts in Differential Offset) with up to 100 V resolution. The PVG's output can be selected as an input to the inverting (-) input of the amplifier for operation as a differential comparator or applied internally as a true differential offset voltage. The PVG is also available for external use through a rear panel connector.

The DA1855A operates from 90 to 250 VAC line without line switching.

High-performance differential probes such as the DXC100 10/100 high CMRR probes are recommended.

Overdrive Recovery

With a 100 probe, the DA1855 settles to within 100 mV referred to input, from a 400 V input signal within 100 ns. With attenuating probes, this allows the in circuit measurement of dynamic saturation in switch mode power converter switching devices.

Comparator Mode

The DA1855A becomes a differential comparator when the internal Precision Voltage Generator (PVG) output is selected as the amplifier's inverting (-) input. In this mode, the DA1855A can be used to very accurately measure relatively small signals that are riding on large AC or DC components. Due to the precision of the voltage generator, an oscilloscope, when used with the DA1855A, can make voltage measurements that are much more accurate than the oscilloscope is capable of by itself. The output of the PVG is available for external use via a rear panel connector.

True Differential Offset Mode

The DA1855A has built-in Precision Voltage Generator can be used to generate a true differential offset while still allowing both inputs to be used as differential inputs. The offset range can be as high as 50,000 divisions and the generator has 5 1/2 digit resolution. This mode facilitates making measurements such as changes to a transistor's base to emitter voltage caused by variations in temperature and/or current. Used in this mode, the voltage generator can be set to a value that will zero out the static value of the junction's on voltage. The DA1855A's differential measurement capability will reject any dynamic signal common to both sides of the junction, and the oscilloscope is left to measure only the changes in the junction voltage.

Autobalance

Each time either gain setting button is pressed, the DA1855A automatically adjusts the amplifier's DC Balance.

Specifications

Nominal
Amplifier gain: x1 or x10
Output impedance: 50 ohm
Intended output load: 50 ohm
Maximum output: limited at 0.50 V into 50 ohm.
Input attenuation: 1 or 10
 
Overdrive Recovery (Typical): In X10 gain, amplifier settles within 1 mV referred to the input within 100 nsec from 4 V input.
(8000% overdrive)
Input Resistance:
(1 Attenuator, x1 or x10 GAIN): 1 MΩ or 100 MΩ
(10 Attenuator, x1 or x10 GAIN): 1 MΩ
Input capacitance 
(1 or 10)
:
20 pF
Bandwidth limit filters: 20 MHz,1.0 MHz and 100 kHz
Filter characteristics: 18 dB/octave  (3-pole Bessel)
+ Input selections: AC, OFF (precharge), DC
- Input selections: AC, OFF (precharge), DC, Vcomp
Input coupling capacitor: 0.1 F, 400 V DC
Input protection: protected to 250 V, automatic input disconnect with manual reset.
  
Differential offset accuracy:
(Typical)
(x10 GAIN, 1 Attenuator): 0.1% + 50 V2
(x1 GAIN,1 Attenuator): 0.1% + 500 V2
(x10 GAIN, 10 Attenuator): 0.15% + 500 V2
(x1 GAIN, 10 Attenuator): 0.15% + 5 mV2
 
 
Warranted Characteristics
Gain accuracy: 1% + uncertainty of termination resistance
Output Zero: ≤2 mV referred to input
Bandwidth: >100 MHz (X1 gain, -3dB)
Risetime: <3.5 ns (calculated from bandwidth)
Common mode rejection ratio, X1 or X10 Gain, 1 Attenuation:
≥ 50,000:1 (94 dB) @ 70 Hz
≥ 50,000:1 (94 dB) @ 100 kHz
≥ 316:1 (50 dB) @ 10 MHz
 
  
Dynamic Ranges
Max differential linear input:
500 mV
x (combined internal and probe's attenuation factor)
Gain Setting
  
(x10 GAIN, 1 Attenuator): 50mV or 0.5 V with 10 probe
(x1 GAIN, 1 Attenuator): 0.5V or 5.0 V with 10 probe
(x10 GAIN, 10 Attenuator): 0.5V or 5.0 V with 10 probe
(x1 GAIN, 10 Attenuator): 5.0V or 50 V with 10 probe
 
Maximum input slew rate:
(1 Attenuator, 1 probe): 0.15 V/s
(10 Attenuator or 10 probe): 1.5 V/s
(10 Attenuator and 10 probe): 15 V/s
(1 Attenuator and 100 probe): 15 V/s
(10 Attenuator and 100 probe): 150 V/s
 
Max Common Mode Range:
(1 Attenuator): 15.5 V (x1 or x10 GAIN)
(10 Attenuator): 155 V (x1 or x10 GAIN)
(10 Attenuator and x10 probe): 1.55 kV (x1 or x10 GAIN)
 
Differential Offset Range (VDIFF mode referred to input)
(x10 GAIN, 1 Attenuator): 1 V
(x1 GAIN, 1 Attenuator): 10 V
(x10 GAIN, 10 Attenuator): 10 V
(x1 GAIN, 10 Attenuator): 100 V
(x1 GAIN, 10 Attenuator, x10 probe): 1.0 kV
Comparison Offset Range (Vcomp mode, referred to input):
(1 Attenuator): 15.5 V (x1 or x10 GAIN)
(10 Attenuator): 155 V (x1 or x10 GAIN)
(x10 probe and 10 Attenuator): 1.55 kV (x1 or x10 GAIN)
 
 
Precision Voltage Source
Output range: 15.5 V
DC accuracy: 0.05% of reading +500 V (15 to 45C)
Control: Oscilloscope offset knob
  
 
Power Requirements
Line voltage requirement: 90 to 250 V AC
Line frequency range: 45 - 66 Hz
Power Consumption: ~28 W, ~ 39 VA
Environmental Characteristics
Operating Range: 0 to 50C
Non-Operating: -4 to 75C
  
 
Physical Characteristics
Height: 7.29 cm (2.87")
Width: 21.2 cm (8.36")
Depth: 23.2 cm (9.12")
Weight: 2.15 kg (4.75 lb)
Shipping Weight: 3.12 kg (6.88 lb)
 
Warranty: 3 years 
 
Model Description  
DA1855A 100 MHz Differential Amplifier with Precision Source; Probe Sensing

DA1855A-PR2 2 Ch, 100 MHz Differential Amplifier and Comparator with Precision Voltage Source and Bandwidth Limit (10 MHz, 1 MHz, 100 MHz).

Model Description  
DXC100A 100:1 or 10:1 Selectable 250 MHz Passive Differential Probe Pair
DXC200 1:1, 50 MHz Passive Differential Probe Pair
DXC5100 100:1, 250 MHz, 2.5kV High Voltage Probe Pair
DA101 10:1, 1 MOhm Passive Attenuator
DA18XX-RM01 Rackmount Adapter for DA18XX-PR2, Size (2U)
(Must be ordered with instrument)
 
To view a list of DISCONTINUED PRODUCTS click this link.

  

DA1855A Information
Specs
Order Information