PRODUCTS    

Oscilloscopes
Protocol Analyzers
Differential Amplifiers
Probes
Automotive/Vehicle Test
Mixed Signal Test Solutions
Modular Instruments
Scope Accessories
Hardware Options
Software Options
Discontinued Products
    

MT01/MT02 Mask Tester
Datasheet

Leading
Features

  • Easy to Use
  • Exclusive: Works on Random Bit Streams
  • Self-Aligning
  • Self-Scaling
  • Includes all Necessary Balanced and Coax Adapters
  • Dedicated Menus
  • Full Remote Control Support for Production Test

 

 
LeCroy's powerful and innovative Mask Tester instantly transforms your digital oscilloscope into a dedicated mask-testing device, specifically designed for manufacturing, type approval and field testing. * Easy to use: the Mask Tester takes over control of the oscilloscope. The scope displays only the Tester's dedicated menus, blocking unneeded control and reducing setup errors
* Powerful: the Tester's exclusive Finder function allows pulses or patterns to be easily isolated - even from random-bit streams. Mask alignment is totally automatic, saving valuable testing time. * Convenient: included in the package are all the twisted-pair and 75 interfaces you'll need for quality cable termination and exact amplitude scaling.



The AP100 ProBus adapter provides adequate interfacing and scaling for ANSI/DS-1 signals.

Dedicated Mask Tester

With the MT01 or MT02 Mask Tester, your LeCroy digital oscilloscope becomes a powerful, dedicated mask-testing instrument.

Power & Innovation

Do you ever wish your oscilloscope could isolate a pulse in that scrambled STS-1 signal? Your wish is granted using the Mask Tester's exclusive Finder search engine.

Capturing and aligning certain telecom signals can be tricky. But Finder uses pattern recognition. Pulse isolation can be performed at all bit rates, on any random bit stream, eliminating the need for sophisticated pattern generators.


Testing the 155 Mb/s SONET/SDH electrical signal. Notice how the "1" pattern is cleanly isolated in this PRBS stream.

Click on the image above to view the Mask Tester Video

 

Some CMI encoded signals (STS-3E, STM-1E, 140 Mb/s) tolerate a limited amount of offset (± 0.05 V) when the signal is adjusted to the mask. The Mask Tester does this automatically, prompting the user if the offset goes beyond limits. And as required by the standard, the resulting offset adjustment is propagated to both masks ("1" and "0").

Ease of Use

The Mask Tester's powerful features are even easier to use thanks to another innovation: the Tester takes over complete control of the scope. It shows only those on-screen menus dedicated to the application, blocking unneeded front-panel controls. This simplifies operation and reduces operator error. The general purpose DSO is made to "think and act" exactly like a dedicated mask tester.

Maximum Convenience

Twisted-pair and 75 Ohm lines can easily be interfaced to the oscilloscope via intelligent ProBus adapters. These adapters provide the scope with both correct line termination and accurate amplitude scaling. The balanced adapters are Op-Amp based, providing ultra-wide bandwidth, flat-frequency response, and overall low distortion. Signal fidelity is assured.

Full Remote-Control Support

All Mask tester functions are available using high-level remote-control commands. And because the functions are specially designed and tailored to the Tester, it takes fewer than ten commands to control all of them. This makes ATE integration fast and painless.

 

Specifications

Supported Mask Tests (all electrical pulse masks)

MT01: E1 (2 Mb/s), E2 (8 Mb/s), E3 (34 Mb/s), E4 (140 Mb/s "0" and "1"), and STM-1e (156 Mb/s "0" and "1").

MT02: DS-1, DS-3, STS-1, STS-3 ("0" and "1").

Signal Adapters

MT01: 120 Ohm balanced adapter with Siemens-type banana connector, 75 Ohm coax adapter.

MT02: 100 Ohm balanced adapters with Bantam-type connector.

Features

MT01:

  • Automatic Signal to mask alignment.
  • Cable attenuation compensation.
  • 4 selectable PASS/FAIL actions: "Stop", "Hardcopy", "Store", "Beep".
  • "1" and "0" CMI pulse extraction for 140 and 156 Mb/s.
  • Convenient offset management for 140 and 156 Mb/s.
  • 120 Ohm balanced and 75 Ohm coax ProBus adapters: automatic scale compensation for accurate amplitude readout.

 

MT02:
  • Exclusive, "Isolated pulse" extraction on random bit stream following ANSI T1.102 requirements.
  • 4 selectable PASS/FAIL actions: "Stop", "Hardcopy", "Store", "Beep".
  • "1" and "0" CMI pulse extraction for 140 and 156 Mb/s.
  • Convenient offset management for 140 and 156 Mb/s.
  • 100 Ohm balanced, and 75 Ohm coax ProBus adapters: automatic scale compensation for accurate amplitude readout.

Warranty: Three years.



The AP120 ProBus adapter, the twisted pair G.703 2 Mb/s signals correctly terminated and scaled.Table of supported signals, together with their encoding and isolating patterns.

Ordering Information
ITU G.703 electrical pulse masks, includes 120 ‡
balanced and 75 Ohm coax adapters.
MT01
ANSI T1.102 electrical pulse mask includes 100 Ohm
balanced and 75 Ohm coax adapters.
MT02
Bundled MT01 + MT02 package MT01/02
Field upgrade for MT01 RK-MT01
Field upgrade for MT02 RK-MT02
Field upgrade for MT01 + MT02 RK-MT01 + MT02
Copyright © LeCroy Corporation 2008