| Signal Capture |
|
Bandwidth (-3 dB) |
@ 50 ?: DC to 2 GHz * ; @ 1 M?: Bandwidth depends on probe used |
|
Number of Channels |
4 |
|
Sample Rate and Acquisition Memory
|
See table below |
|
Active Channels |
Max Sampling Rate |
Max Record Length |
|
4 |
4 GS/s |
16 M |
|
2 |
8 GS/s |
32 M |
|
1 |
16 GS/s |
64 M |
|
|
Sensitivity |
50 ?: 1mV - 1 V/div fully variable; 1 M?, 1mV - 2 V/div fully variable |
Scale Factors
|
Choice
of over 12 probe attenuation factors selectable via front-panel menus |
Offset Range
|
50? or 1 M?: 1 mV - 4.99 mV/div: +400 mV
50?: 5 mV - 99 mV/div: +1 V; 0.1 - 1V/div: +10 V
1M? : 5 mV - 100 mV/div: +1 V; 0.101 V - 2 V/div: +20 V |
|
DC Accuracy |
(±) 2.0% full scale + 1.5% offset value @ gain >10mV |
|
Vertical Resolution
|
8 bits, up to 11 bits with enhanced resolution
(ERES) |
|
Bandwidth Limiters |
20 MHz, 200 MHz |
|
Input Coupling |
1M?: AC, DC,
GND,; 50?: DC, GND |
|
Input Impedance |
50 ? ±1.5%; 10 M? // 11 pF typical (using PP005 probe) |
Max Input Voltage
|
50 ?: ±5 V DC (500
mW) or 5 vrms; 1 M?: 100 Vmax (peak AC <5 kHz + DC) |
|
Acquisition Modes |
|
Random Interleaved Sampling (RIS)
|
50 GS/s. For repetitive signals from 200
ps/div 1 µs/div |
|
Single-Shot
|
For transient and repetitive signals from 200
ps/div 1000 s/div |
Sequence
|
Stores multiple events each of them time stamped (1 ns resolution) in segmented acquisition memories |
|
Sequence Mode Dead Time
|
Typically 30 µs |
|
Number of Segments Available |
2 8000
|
|
Timebase System |
|
Timebases |
Main and up to four zoom traces |
|
Time/Div Range
|
200
ps/div 1000 s/div |
|
Rapid Signal Processing |
|
Microprocessor
|
Motorola PowerPC 603e |
|
System Memory Configuration
|
256 Mbytes |
|
Video Memory |
1 Mbyte |
|
Persistence Data Map Memory |
16 bits per displayed pixel (64k levels) |
Waveform Processing
|
Up to four processing functions can be performed simultaneously. Functions available are: Add, Subtract, Multiply, Divide, Negate, Identity, Summation Averaging, Sine x/x, Integral, Derivative, Square Root, Ratio, Absolute Value, Resample
(deskew), Rescale Exp Log, and the advanced functions listed below |
Average
|
Summation: Up to 106 averages possible. Continuous: Weighting factors from 1:1 to 1:1023 |
|
Extrema
|
Roof, Floor, or Envelope values from 1 to 106 sweeps |
ERES
|
Low Pass digital filters provide up to 11-bit vertical resolution. Sampled data is always available, even when a trace is turned off. |
|
FFT |
Spectral analysis with five windowing functions (Rectangular, Von
Hann, Hamming, Flat Top, Blackman-Harris) and FFT averaging |
Statistical Diagnostics
|
The parameter analysis package permits in-depth diagnostics on waveform parameters. Live histogramming and trending of any waveform parameter measurement is possible. The histogram can be autoscaled to display the center and width of the distribution. |
|
Histogramming
|
Generate history of waveform parameter calculations. |
|
Trending |
Generate trend sequence of waveform parameter calculations.
|
Correlation
|
Calculate
the normalized correlation coefficient between two signals. |
* for sampling rates > 4 GS/s
|

|
|