9350A Family Digital Oscilloscopes
500 MHz Bandwidth, 2 GS/s
Main Features
- Two and Four Channel versions
- Up to 8M Point record length
- DOS Compatible Floppy Disk, PCMCIA potable hard drive and Memory
Card options
- Innovative Peak Detect Mode
- Glitch, Pattern, Qualified, Interval, Dropout and Video Triggers
- 8-bit vertical resolution, 11 with ERES option
- Fully programmable via GPIB and RS-232-C
- Automatic PASS/FAIL testing
- Advanced Signal Processing
- Internal High Resolution Graphics
High speed and long memory make this family the ideal 500 MHz
general-purpose Digital Storage Oscilloscopes. Two and four channel simultaneous sampling
at 500 MS/s meets demanding high-speed design applications. Even faster sampling may be
achieved by combining channels, up to a maximum of 2 GS/s. Acquisition memories may also
be combined, providing up to 8 M points of continuous or segmented waveform recording.
Repetitive signals are digitized at up to 10 GS/s.
A unique peak detect scheme triggers on glitches down to 1ns and
keeps the ADC sampling at 2.5 ns - even at slow time bases - without destroying the
underlying data. This provides circuit designers with the benefits of peak detection
without any loss of precision.
Live waveforms on the main timebase may be viewed simultaneously
with up to 3 expansions, showing all of the signal detail. Expansions are shown as
highlights on the main trace. Each zoomed detail may be expanded horizontally and
vertically as required.
SMART Trigger modes like Glitch, Pattern, Dropout and TV allow you
to capture precisely the events of interest. Pre- and Post-Trigger delay, and Time and
Events Holdoff are also standard. The 9350A family features the proven user-interface of
LeCroy's portable scopes. A bright 9" CRT allows optimum waveform viewing on a high
resolution 810 x 696 pixel screen. Menus and text are arranged around the graticules -
they never overwrite the waveforms. Dedicated control knobs keep the scope's performance
at your fingertips.
A comprehensive range of signal processing functions including FFT
and Math on live or stored waveforms, allows extensive waveform manipulation. Up to 16
MBytes of RAM are standard allowing advanced processing including FFT's up to 1 Mpoint.
For the most powerful processing in the industry, a 64 MByte RAM option is available. DOS
compatible floppy disk, PCMCIA portable hard drive and memory card options store waveforms
and test setups, and simplify data transfer to any PC. An optional high resolution
graphics printer is also available.
ACQUISITION SYSTEM
Bandwidth (-3 dB): DC to 500 MHz
No. of Channels:
4 (9354A) or 2 (9350A)
No. of Digitizers:
4 (9354A) or 2 (9350A)
Maximum Sample Rate:
2 GS/s (9354A) or 1 GS/s (9350A)
Acquisition Memory: Up to 8 M (see table below).
Sensitivity: 2 mV/div to 5 V/div, fully variable.
Scale factors: A wide choice of over 12 probe attenuation
factors are selectable.
Offset Range: 2.0 - 9.9 mV/div: ± 120 mV
10.0 - 199 mV/div: ± 1.2 V
0.2 - 5.0 V/div: ± 24 V
±20 V across the whole sensitivity range when using the AP 020 FET
probe.
DC Accuracy: < or equal to±2% full scale.
Vertical Resolution: 8 bits.
Bandwidth Limiter: 30 MHz
Input Coupling: AC, DC, GND.
Input Impedance: 1 M Ohm//14 pF or 50 Ohms ± 1%.
Max Input:
1 M Ohm: 250 V (DC+peak AC < or equal to 10 kHz)
50 Ohms: ± 5 V DC (500 mW) or 5 V RMS
TIME BASE SYSTEM
Timebases: Main and up to 4 Zoom Traces.
Time/Div Range: 1 ns/div to 1000 s/div.
Clock Accuracy: < or equal to 10 ppm
Interpolator resolution: 10 ps
Roll Mode: Ranges 500 ms to 1,000 s/div.
For > 50k points: 10 s to 1,000 s/div.
External Clock: < or equal to 100 MHz on EXT input with
ECL, TTL or zero crossing levels up to 500 MHz with option 935XA-CKTRIG.
TRIGGERING SYSTEM
Trigger Modes: Normal, Auto, Single.
Trigger Sources: CH1, CH2, Line, Ext, Ext/10 (9354: CH3,
CH4), Slope, Level and Coupling for each can be set independently.
Slope: Positive, Negative.
Coupling: AC, DC, HF, LFREJ, HFREJ.
Pre-trigger recording: 0 to 100% of full scale (adjustable in
0.1 div increments).
Post-trigger delay: 0 to 10,000 divisions (adjustable in
0.01% increments).
Holdoff by time: 10 ns to 20 s.
Holdoff by events: 0 to 99,999,999 events.
Trigger Bandwidth: Up to 500 MHz using HF coupling.
Internal Trigger Sensitivity Range: ± 5 div.
EXT Trigger Max Input:
1 M Ohm//15 pF: 250 V (DC+peak AC < or equal to 10 kHz)
50 Ohms ± 1%: ± 5 V DC (500 mW) or 5 V RMS
EXT Trigger Range: ±0.5 V (±5 V with Ext/10)
Trigger Timing: Trigger Date and Time are listed in the
Memory Status Menu.
SMART TRIGGER TYPES
Pattern: Trigger on the logic AND of 5 inputs - CH1, CH2,
CH3, CH4, and EXT Trigger, (9350: 3 inputs - CH1, CH2, EXT) where each source can be
defined as High, Low or Don't Care. The Trigger can be defined as the beginning or end of
the specified pattern.
Signal or Pattern Width: Trigger on glitches as short as 1
nsec or on pulse widths between two limits selectable from < 2.5ns to 20s.
Signal or Pattern Interval: Trigger on an interval between
two limits selectable from 10ns to 20s.
Dropout: Trigger if the input signal drops out for longer
than a time-out from 25ns to 20s.
State/Edge Qualified: Trigger on any source only if a given
state (or transition) has occurred on another source. The delay between these events can
be defined as a number of events on the trigger channel or as a time interval.
TV: Allows selection of both line (up to 1500) and field
number (up to 8) for PAL, SECAM, NTSC or non-standard video.
ACQUISITION MODES
Random Interleaved Sampling (RIS):
for repetitive signals from 1 ns/div to 2 µs/div (M,L versions:
from 1 ns/div to 5 µs/div).
Single shot: for transient and repetitive signals from 10
ns/div (all channels active).
Peak detect: captures and displays 2.5 ns glitches or other
high-speed events.
Sequence: Stores multiple events - each of them time stamped
- in segmented acquisition memories.
Number of segments available:
9350A-9354A 2-50
9350AM-9354AM-9354TM 2-500
9350AL-9354AL 2-2,000
DISPLAY
Waveform style: Vectors connect the individual sample points,
which are highlighted as dots. Vectors may be switched off.
CRT: 12.5 x 17.5 cm (9" diagonal) raster.
Resolution: 810 x 696 points.
Modes: Normal, X-Y, Variable or Infinite Persistence.
Real-time Clock: Date, hours, minutes, seconds.
Graticules: Internally generated; separate intensity control
for grids and waveforms.
Grids: 1, 2 or 4 grids.
Formats: YT, XY, and both together.
Vertical Zoom: Up to 5x Vertical Expansion (50x with
averaging, up to 40 µV sensitivity).
Horizontal Zoom Factors:
9350A-9354A 500x
9350AM-9354AM-9354TM 2,000x
9350AL-9354AL 40,000x
INTERNAL MEMORY
Waveform Memory: Up to four 16-bit Memories (M1,M2,M3,M4).
Processing Memory: Up to four 16-bit Waveform Processing
Memories (A,B,C,D).
Setup Memory: Four non-volatile memories. Optional Cards or
Disks may also be used for high-capacity waveform and setup storage.
AUTOMATIC MEASUREMENTS
The following Parametric measurements are available, together with
statistics of their Average, Highest, Lowest values and Standard Deviation:
| amplitude |
delta t at level (t=0,abs) |
overshoot + |
| area |
delta t at level (t-0%) |
overshoot - |
| base |
duty cycle |
peak to peak |
| cmean |
falltime |
period |
| cmedian |
f80-20% |
risetime |
| crms |
f@level (abs) |
r20-80% |
| csdev |
f@level (%) |
r@level (abs) |
| cycles |
frequency |
r@level (%) |
| delay |
maximum |
RMS |
| delta delay |
mean |
std dev |
| delta t at level (abs) |
median |
top |
| delta t at level (%) |
minimum |
width |
Parameters are calculated as defined by ANSI/IEEE Std 181-1977
"Standard on Pulse Measurement and Analysis by Objective Techniques". In
addition, Rise and Fall times may be measured at 10 % and 90% levels, or 20% and 80%
levels, or any other user-specified levels.
delta delay provides time between midpoint transition of two
sources, for making propagation delay measurements.
delta t at level allows the same measurement to be made at any
specified level.
Two cursors are used to define the region over which these
parameters are calculated.
Relative Time: Two cursors provide time measurements with
resolution of ±0.05% full scale for unexpanded traces; up to 10 % of the sampling
interval for expanded traces. The corresponding frequency value is also displayed.
Relative Voltage: Two horizontal bars measure voltage
differences up to ±0.2% of fullscale in single-grid mode.
Absolute Time: A cross hair marker measures time relative to
the trigger, and voltage with respect to ground.
Pass/Fail testing allow up to five of the listed parameters
to be tested against selectable thresholds. Waveform Limit Testing is performed using
templates which may be defined inside the instrument.
WAVEFORM PROCESSING
Up to four processing functions may be performed simultaneously.
Functions available are: Add, Subtract, Multiply, Divide, Negate, Identity, Sin (x)/x and
Summation Averaging.
Average: Summed averaging of up to 1,000 waveforms in the
basic instrument. Up to a million sweeps are possible with Option WP01.
Envelope*: Max, Min, or Max and Min values of up to one
million sweeps.
ERES*: Low-Pass digital filter provides up to 11 bits
vertical resolution.
Sampled data is always available, even when a trace is turned off.
Any of the above modes can be invoked without destroying the data.
FFT*: Spectral Analysis with four windowing functions and FFT
averaging.
*Envelope and ERES modes are provided in Math Package WP01, FFT is
in WP02.
AUTOSETUP
Pressing Autosetup sets timebase, trigger and sensitivity to display
a wide range of repetitive signals. (Amplitude 2mV to 40V; frequency above 50Hz; Duty
cycle greater than 0.1%).
Autosetup Time: Approximately 2 seconds.
Vertical Find: Automatically sets sensitivity and offset.
PROBES
Model: One PP002 (X10, 10 M Ohm // 15 pF) probe supplied per
channel.
The 9350 family is fully compatible with LeCroy's range of FET
Probes, which may be purchased separately.
Probe calibration: Max 1 V into 1 M Ohm,
500 mV into 50 Ohms , frequency and amplitude programmable, pulse or
square wave selectable, rise and fall time 1 ns typical.
Alternatively, the Calibrator output can provide a trigger output or
a PASS/FAIL test output.
INTERFACING
Remote Control: All front-panel controls, as well as all
internal functions are possible by GPIB and RS-232-C.
RS-232-C Port (Standard): Asynchronous up to 19200 baud for
computer/terminal control or printer/plotter connection.
GPIB Port (Standard): (IEEE-488.1) Configurable as
talker/listener for computer control and fast data transfer. Command Language complies
with requirements of IEEE-488.2.
Centronics Port: Optional hardcopy parallel interface
included with floppy disk and graphics printer option.
Hardcopy: Screen dumps are activated by a front-panel button
or via remote control. TIFF format is available for importing into Desktop Publishing
programs. The following printers and plotters can be used to make hardcopies:
HP DeskJet (color or B&W), HP ThinkJet, QuietJet, LaserJet, PaintJet and EPSON
printers. HP 7400 and 7500 series, or HPGL compatible plotters.
An optional internal high resolution graphics printer is also available.
GENERAL
Auto-calibration ensures specified DC and timing accuracy.
Temperature: 5° to 40° C (41° to 104° F) rated, 0° to
50° C (32° to 122° F) operating.
Humidity: < 80%.
Shock & Vibration: Meets MIL-STD-810C modified to LeCroy
design specifications and MIL-T-28800C.
Power: 90-250 V AC, 45-66 Hz, 230 W.
Battery Backup: Front-panel settings maintained for two
years.
Dimensions: (HWD) 8.5" x 14.5" x 16.25", 210mm
x 370mm x 410mm.
Weight: 13 kg (28.6 lbs) net,
18.5 kg (40.7 lbs) shipping.
Warranty: 3 years.
Memory Per Channel
|
Channels Used
|
Maximum
Sample Rate |
9350A
9354A |
9350AM
9354AM |
9354TM |
9350AL
9354AL |
Notes |
All, Peak Detect
OFF |
500 MS/s |
50k |
250k |
500k |
2M |
All channels
active |
All, Peak Detect
ON |
100 MS/s data
400 MS/s peak |
25k data+ 25k
peaks |
100 data +
100 peaks |
250k data + 250k
peaks |
1M data +
1M peaks |
All channels
active 2.5 ns peak detect |
Paired Peak
Detect OFF |
1 GS/s |
100 |
500 |
1M |
4M |
9350;
CH1 9354A;
Ch2 + Ch3 |
Paired + PP093
Peak Detect OFF |
2 GS/s |
200 |
1000 |
2M |
8M |
9354A Models Only
|
|