DDA 7 Zi Series

DDA 7 Zi Series

Based on the WavePro 7 Zi Series models, the DDA 7 Zi Series Disk Drive Analyzers are available in 3.5 and 6 GHz models and come equipped with 20 Mpts/ch acquisition memory. Dedicated disk drive measurements, trigger and zooming for failure analysis, and serial data measurement capability with a Disk Drive Analyzer user interface are also standard to address high capacity disk drive designs. Operate in either DDA or SDA mode to analyze the serial data links or the physical media behavior on a hard drive.

- Zoom on multi-zoom on sectors

- One button access to read channel emulation, servo analysis, and disk drive triggers

- Head equalization, channel Emulation, and SAM histograms

- Segmented memory for sector by sector parametric analysis



A Total Solution for Disk Drive Analysis
Maximum Performance
LeCroy Disk Drive Analyzers (DDA) assist data storage design engineers by integrating tools that improve the time to market of new products and accelerate understanding and failure analysis on existing drives. LeCroy continues that tradition with the DDA 7 Zi Series equipped with its powerful Disk Drive Analysis toolset. Capture, view, and analyze the wave shape of high-speed, complex drive signals with speed and integrity.
Data Storage applications are memory intensive as capturing multiple sectors or a complete track of data can be important in troubleshooting a design or characterizing media.
The X-Stream II architecture enables fast and accurate measurements and analysis of disk drive signals. Memory can be extended to 128 Mpts/Ch (256 Mpts/Ch on 2 Ch) using Option L. Both the DDA 760Zi and DDA 735Zi offer the convenience of selectable 50 Ω or 1 MΩ inputs. The standard 20 Mpts of waveform memory and 40 GS/s capture on two channels, means multiple drive sectors can be acquired at once.
Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 6 GHz, and then QuickZoom it from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. Disk drive parameters let you characterize the pulse width variation or signal-to-noise ratio across a region. Failure Analysis engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good drives. Analog-to-digital converters running at speeds up to 40 GS/s ensure the right sensitivity to measure today’s high-speed read channels. In every DDA, you can run your customer-developed scripts to view the captured signal with the filters matched to your channel and media. Custom user scripts can be created in MATLAB, Visual Basic, Excel or other formats.
Exceptional Trigger and Sequence Performance
The DDA’s disk triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with up to 50 picosecond/sample time resolution. Up to 15,000 sectors of data can be gathered with the DDA 7 Zi analyzers. An optional capability, Streaming Sequence, uses the X-Stream II and the fast hardware architecture of the DDA to streamup to 300,000 segments of data to memory; all taken at a high trigger rate.
Natural Graphical Interface
One press on the DDA menu takes you directly to the Disk Drive Analyzer features. The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, react quickly to your commands. Functionality is exactly where you expect it to be.
The DDA 7 Zi provides one button access to all the tools needed to accurately debug and analyze disk drive operation.
The DDA 7 Zi features:
  • 31 custom parameters
  • 4 specific drive trigger
    • Sector
    • Servo Gate
    • PES trigger
    • Read Gate Trigger
  • Advanced drive analysis tools
Advanced Disk Drive analysis tools capabilities include:
  • Head Filter Equalizer emulation
  • Channel Emulation
  • SAM Histograms
  • Plot of SAM values
  • PES runout analysis
  • Analog Compare
Simultaneously connecting low-speed signals, like index and servo gate, and high-speed signals, like read channels has never been easier. With integrated 50 Ω and 1 MΩ inputs on all models, there is no longer a need for expensive adapters.
DDA 735Zi
Analog Bandwidth @ 50 Ω (-3 dB)
  3.5 GHz
Rise Time (typical)
  120 ps
Input Channels
  4
Bandwidth Limiters
  20 MHz, 200 MHz
Input Impedance
  50 Ω or 1 MΩ||15pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling
  1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage
  50 Ω: ±5 Vrms
Vertical Resolution
  8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity
  50 O: 2 mV–1 V/div, fully variable (2-9.99 mV/div via zoom); 1 MO: 2 mV–10 V/div, fully variable
DC Gain Accuracy
  ±1.5% of full scale
Offset Range
  50 Ω:
Offset Accuracy
  ±(1.5% of full scale + 1.0% of offset value + 1 mV)
Timebases
  Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range
  20 ps/div–1000 s/div (RIS mode: 20 ps/div - 10 ns/div; Roll mode: up to 1000 s/div)
Clock Accuracy
  < 1 ppm
Jitter Noise Floor
  800 fs (typical)
Trigger and Interpolator Jitter
  2 psrms (typical)
Sample Rate and Delay Time Accuracy
  < 0.06 / SR + (1 ppm * Reading) (rms)
Channel-Channel Deskew Range
  ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)
  10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output)
  10 MHz; 50 Ω impedance, output at the rear
External Sample Clock
  0.1 Hz-100 MHz, 50 Ω or 1 MΩ impedance, applied at the auxiliary input
Single-Shot Sample Rate/Ch
  40 GS/s on 2 Ch
Random Interleaved Sampling (RIS)
  200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate
  1,250,000 waveforms/s (in Sequence Mode, up to 4 channels)
Intersegment Time
  800 ns
Standard Memory (4 Ch / 2 Ch) (Number of Segments)
  10 M / 20 M
S - Memory Option
  32 M / 64 M
M - Memory Option
  64 M / 128 M
L - Memory Option
  128 M / 256 M
Averaging
  Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)
  From 8.5 to 11 bits vertical resolution
Envelope (Extrema)
  Envelope, floor, or roof for up to 1 million sweeps
Interpolation
  Linear or Sin x/x
Modes
  Normal, Auto, Single, and Stop
Sources
  Any input channel, Aux, Aux/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode
  DC, AC, HFRej, LFRej
Pre-trigger Delay
  0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay
  0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or Events
  From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range
  ±5 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs
  2 div @ < 3.5 GHz
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs
  Not Applicable
External Trigger Sensitivity
  2 div @ < 1 GHz
External Trigger Input Range
  Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger
  2.0 GHz @ = 10 mV/div (minimum signal width setting 250 ps)
Edge/ Slope/ Line
  Triggers when signal meets slope (positive, negative, or either) and level condition.
TV-Composite Video
  Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
State or Edge Qualified
  Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout
  Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern
  Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
Glitch
  Triggers on positive or negative glitches with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Width (Signal or Pattern)
  Triggers on positive or negative widths with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Interval (Signal or Pattern)
  Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)
  Triggers on any source if a given state (or transition edge) has occurred on another source.
Runt
  Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate
  Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
"A" Trigger List
  Edge, Window, Width, Glitch, Pattern, Pattern State, State, Dropout, Interval, Runt, Slew Rate, Serial Data (optional I2C, SPI, UART/RS-232, CAN, LIN, FlexRay)
"B" Trigger List
  Edge
Exclusion Triggering
  Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Holdoff Between Sequential Triggers
  Arming = Serial & Triggering = Anything, then min. time between events defined by serial pattern length
Data Rates
  50 Mb/s - 1.25 Gb/s
Pattern Length
  80 bits, NRZ or 8b10b
Clock and Data Outputs
  400mVp-p (typical) AC coupled
Clock Recovery Jitter
  1 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density
Clock Recovery Tracking/ Acquisition Range
  50 Mb/s - 1.25 Gb/s
Hardware Clock Recovery Loop BW
  PLL Loop BW = Fbaud/5500, 50 Mb/s to 1.25 Gb/s (typical)
Optionally available
  I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay
Intensity
  256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels
  up to 4 simultaneously
Max Sampling Rate
  40 GS/s (20 GS/s for WavePro 710Zi without WPZi-1GHZ-4X20GS option)
Waveforms
  up to 2500 Waveforms/ second
Auto Setup
  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale
  Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
Probes
  Qty. (4) ÷10 Passive Probes
Probe System: ProBus
  Probus (and ProLink on 4-6 GHz models). Automatically detects and supports a variety of compatible probes
Scale Factors
  Automatically or manually selected depending on probe used
Calibration Output
  1kHz square wave, 1Vp-p (typical), output to probe hook
Type
  Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution
  WXGA; 1280 x 768 pixels
Number of traces
  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles
  Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation
  Sample dots joined, or sample dots only
Analog and Color-Graded Persistence
  Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection
  Activate persistence on all or any combination of traces
Sweep Display Modes
  All accumulated, or all accumulated with last trace highlighted
Persistence Types
  Select analog, color, or three-dimensional
Persistence Aging
  Select from 500 ms to infinity
Front Panel and Instrument Status
  Store to the internal hard drive or to a USB-connected peripheral device.
Type
  LeCroy LSIB
Transfer Rate
  250 Mpt/s
Output Protocol
  PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol
  TCP/IP
Command Set
  Via Windows Automation, or via LeCroy Remote Command Set
Type
  Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory
  2 GB standard, up to 8 GB optional
Operating System
  Microsoft Windows® Vista Business Edition (64-bit) with SP1
Oscilloscope Operating Software
  Entire instrument including any installed optional applications packages operates within a single (X-Stream) Windows application
Real Time Clock
  Date and time displayed with waveform an in hardcopy files. SNTP support to synchronize to precision internal clocks.
Zoom Expansion Traces
  Display up to 4 Zoom and 8 Math/Zoom traces
Internal Waveform Memory
  4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
Remote Control
  Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port
  Supports IEEE – 488.2
LSIB Port (optional)
  Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB Device Port (optional)
  Type-B
Ethernet Port
  Supports 10/100/1000 BaseT Ethernet interface (RJ45 port)
USB Ports
  minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port
  15 pin D-Type WXGA compatible to support customer-supplied external monitor.
Serial Port
  2 standard
Peripheral Bus
  LeCroy LBUS standard
Signal Types
  Select External Trigger or External Clock Input on the front panel
Coupling
  50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage
  50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
Signal Types
  Select from calibrator, control signals or Off
Calibrator Signal
  5 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals
  Trigger enabled, trigger out, pass/fail status
Auto Calibration
  Ensures specified DC and timing accuracy is maintained for 1 year minimum.
Voltage
  100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption
  850 W/850 VA
Temperature (Operating)
  +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating)
  –20 °C to +60 °C
Humidity (Operating)
  5% to 80% relative humidity (non-condensing) up to +31 °C.
Humidity (Non-Operating)
  5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)
  Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)
  Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)
  0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)
  2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock
  20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
Dimensions (HWD)
  14"H x 18.4"W x 11.4"D (355 x 467 x 289 mm)
Weight
  39.5 lbs. (18 kg)
Shipping Weight
  57.5 lbs. (26 kg)
Certifications
  CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04
Warranty and Service
  3-year warranty; calibration recommended annually.
DDA 760Zi
Analog Bandwidth @ 50 Ω (-3 dB)
  6 GHz
Rise Time (typical)
  70 ps
Input Channels
  4
Bandwidth Limiters
  20 MHz, 200 MHz
Input Impedance
  50 Ω or 1 MΩ||15pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling
  1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage
  50 Ω (ProBus): ±5 Vrms
Vertical Resolution
  8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity
  50 Ω: 2 mV–1 V/div, fully variable (2-9.99 mV/div via zoom); 1 MΩ: 2 mV–10 V/div, fully variable
DC Gain Accuracy
  ±1.5% of full scale
Offset Range
  50 Ω:
Offset Accuracy
  ±(1.5% of full scale + 1.0% of offset value + 1 mV)
Timebases
  Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range
  20 ps/div–1000 s/div (RIS mode: 20 ps/div - 10 ns/div; Roll mode: up to 1000 s/div)
Clock Accuracy
  < 1 ppm
Jitter Noise Floor
  560 fs (typical)
Trigger and Interpolator Jitter
  1 psrms (typical)
Sample Rate and Delay Time Accuracy
  < 0.06 / SR + (1 ppm * Reading) (rms)
Channel-Channel Deskew Range
  ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)
  10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output)
  10 MHz; 50 Ω impedance, output at the rear
External Sample Clock
  0.1 Hz-100 MHz, 50 Ω or 1 MΩ impedance, applied at the auxiliary input
Single-Shot Sample Rate/Ch
  40 GS/s on 2 Ch
Random Interleaved Sampling (RIS)
  200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate
  1,250,000 waveforms/s (in Sequence Mode, up to 4 channels)
Intersegment Time
  800 ns
Standard Memory (4 Ch / 2 Ch) (Number of Segments)
  10 M / 20 M
S - Memory Option
  32 M / 64 M
M - Memory Option
  64 M / 128 M
L - Memory Option
  128 M / 256 M
Averaging
  Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)
  From 8.5 to 11 bits vertical resolution
Envelope (Extrema)
  Envelope, floor, or roof for up to 1 million sweeps
Interpolation
  Linear or Sin x/x
Modes
  Normal, Auto, Single, and Stop
Sources
  Any input channel, Aux, Aux/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode
  DC, AC, HFRej, LFRej
Pre-trigger Delay
  0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay
  0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or Events
  From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range
  ±5 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs
  2 div @ < 3.5 GHz
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs
  2 div @ < 6 GHz
External Trigger Sensitivity
  2 div @ < 1 GHz
External Trigger Input Range
  Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger
  2.0 GHz @ = 10 mV/div
Edge/ Slope/ Line
  Triggers when signal meets slope (positive, negative, or either) and level condition.
TV-Composite Video
  Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
State or Edge Qualified
  Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout
  Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern
  Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
Glitch
  Triggers on positive or negative glitches with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Width (Signal or Pattern)
  Triggers on positive or negative widths with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Interval (Signal or Pattern)
  Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)
  Triggers on any source if a given state (or transition edge) has occurred on another source.
Runt
  Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate
  Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
"A" Trigger List
  Edge, Window, Width, Glitch, Pattern, Pattern State, State, Dropout, Interval, Runt, Slew Rate, Serial Data (optional I2C, SPI, UART/RS-232, CAN, LIN, FlexRay)
"B" Trigger List
  Edge
Exclusion Triggering
  Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Holdoff Between Sequential Triggers
  Arming = Serial & Triggering = Anything, then min. time between events defined by serial pattern length
Data Rates
  50 Mb/s - 3.125 Gb/s
Pattern Length
  80 bits, NRZ or 8b10b
Clock and Data Outputs
  400mVp-p (typical) AC coupled
Clock Recovery Jitter
  1 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density
Clock Recovery Tracking/ Acquisition Range
  50 Mb/s - 2.7 Gb/s
Hardware Clock Recovery Loop BW
  PLL Loop BW = Fbaud/5500, 50 Mb/s to 1.25 Gb/s (typical)
Optionally available
  I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay
Intensity
  256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels
  up to 4 simultaneously
Max Sampling Rate
  40 GS/s (20 GS/s for WavePro 710Zi without WPZi-1GHZ-4X20GS option)
Waveforms
  up to 2500 Waveforms/ second
Auto Setup
  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale
  Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
Probes
  Qty. (4) ÷10 Passive Probes
Probe System: ProBus
  Probus (and ProLink on 4-6 GHz models). Automatically detects and supports a variety of compatible probes
Scale Factors
  Automatically or manually selected depending on probe used
Calibration Output
  1kHz square wave, 1Vp-p (typical), output to probe hook
Type
  Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution
  WXGA; 1280 x 768 pixels
Number of traces
  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles
  Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation
  Sample dots joined, or sample dots only
Analog and Color-Graded Persistence
  Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection
  Activate persistence on all or any combination of traces
Sweep Display Modes
  All accumulated, or all accumulated with last trace highlighted
Persistence Types
  Select analog, color, or three-dimensional
Persistence Aging
  Select from 500 ms to infinity
Front Panel and Instrument Status
  Store to the internal hard drive or to a USB-connected peripheral device.
Type
  LeCroy LSIB
Transfer Rate
  250 Mpt/s
Output Protocol
  PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol
  TCP/IP
Command Set
  Via Windows Automation, or via LeCroy Remote Command Set
Type
  Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory
  2 GB standard, up to 8 GB optional
Operating System
  Microsoft Windows® Vista Business Edition (64-bit) with SP1
Oscilloscope Operating Software
  Entire instrument including any installed optional applications packages operates within a single (X-Stream) Windows application
Real Time Clock
  Date and time displayed with waveform an in hardcopy files. SNTP support to synchronize to precision internal clocks.
Zoom Expansion Traces
  Display up to 4 Zoom and 8 Math/Zoom traces
Internal Waveform Memory
  4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
Remote Control
  Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port
  Supports IEEE – 488.2
LSIB Port (optional)
  Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB Device Port (optional)
  Type-B
Ethernet Port
  Supports 10/100/1000 BaseT Ethernet interface (RJ45 port)
USB Ports
  minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port
  15 pin D-Type WXGA compatible to support customer-supplied external monitor.
Serial Port
  2 standard
Peripheral Bus
  LeCroy LBUS standard
Signal Types
  Select External Trigger or External Clock Input on the front panel
Coupling
  50 Ω: DC; 1 MO: AC, DC, GND
Max. Input Voltage
  50 Ω: 5 Vrms; 1 MO: 250 V (Peak AC < 10 kHz + DC)
Signal Types
  Select from calibrator, control signals or Off
Calibrator Signal
  5 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals
  Trigger enabled, trigger out, pass/fail status
Auto Calibration
  Ensures specified DC and timing accuracy is maintained for 1 year minimum.
Voltage
  100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption
  850 W/850 VA
Temperature (Operating)
  +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating)
  –20 °C to +60 °C
Humidity (Operating)
  5% to 80% relative humidity (non-condensing) up to +31 °C.
Humidity (Non-Operating)
  5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)
  Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)
  Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)
  0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)
  2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock
  20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
Dimensions (HWD)
  14"H x 18.4"W x 11.4"D (355 x 467 x 289 mm)
Weight
  39.5 lbs. (18 kg)
Shipping Weight
  57.5 lbs. (26 kg)
Certifications
  CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04
Warranty and Service
  3-year warranty; calibration recommended annually.
Memory Options
DDAZi-L-128128 Mpt/Ch (256 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 4 GB of RAM (8 GB total)
DDAZi-M-6464 Mpt/Ch (128 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 4 GB of RAM (8 GB total)
DDAZi-S-32 32 Mpt/Ch (64 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 2 GB of RAM (4 GB total)
Data Storage Software
WPZi-DMODDemodulation Software Package for WavePro Zi Series
Serial Trigger and Decode
WPZi-FlexrayBus TDFlexRay Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-FlexRayBus TDPFlexRay Bus Trigger, Decode, and Physical Layer Test Option for WavePro Zi Series Oscilloscopes
WPZi-HSPT50 Mb/s to 3.125 Gb/s High Speed Serial Trigger Option for 4-6 GHz Oscilloscopes & Disk Drive Analyzers
WPZi-I2Cbus TDI2C Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-LINbus TDLIN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-MSPT50 Mb/s to 1.25 Gb/s Medium Speed Serial Trigger Option for 2.5-3.5 GHz Oscilloscopes & Disk Drive Analyzers
WPZi-SPIbus TDSPI Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-UART-RS232bus TDUART and RS232 Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
Mixed Signal Test Solutions
MS-250250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option
MS-500500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36