DDA 7 Zi Series

DDA 7 Zi Series

Based on the WavePro 7 Zi Series models, the DDA 7 Zi Series Disk Drive Analyzers are available in 3.5 and 6 GHz models and come equipped with 20 Mpts/ch acquisition memory. Dedicated disk drive measurements, trigger and zooming for failure analysis, and serial data measurement capability with a Disk Drive Analyzer user interface are also standard to address high capacity disk drive designs. Operate in either DDA or SDA mode to analyze the serial data links or the physical media behavior on a hard drive.

- Zoom on multi-zoom on sectors

- One button access to read channel emulation, servo analysis, and disk drive triggers

- Head equalization, channel Emulation, and SAM histograms

- Segmented memory for sector by sector parametric analysis



A Total Solution for Disk Drive Analysis
Maximum Performance
LeCroy Disk Drive Analyzers (DDA) assist data storage design engineers by integrating tools that improve the time to market of new products and accelerate understanding and failure analysis on existing drives. LeCroy continues that tradition with the DDA 7 Zi Series equipped with its powerful Disk Drive Analysis toolset. Capture, view, and analyze the wave shape of high-speed, complex drive signals with speed and integrity.
Data Storage applications are memory intensive as capturing multiple sectors or a complete track of data can be important in troubleshooting a design or characterizing media.
The X-Stream II architecture enables fast and accurate measurements and analysis of disk drive signals. Memory can be extended to 128 Mpts/Ch (256 Mpts/Ch on 2 Ch) using Option L. Both the DDA 760Zi and DDA 735Zi offer the convenience of selectable 50 Ω or 1 MΩ inputs. The standard 20 Mpts of waveform memory and 40 GS/s capture on two channels, means multiple drive sectors can be acquired at once.
Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 6 GHz, and then QuickZoom it from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. Disk drive parameters let you characterize the pulse width variation or signal-to-noise ratio across a region. Failure Analysis engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good drives. Analog-to-digital converters running at speeds up to 40 GS/s ensure the right sensitivity to measure today’s high-speed read channels. In every DDA, you can run your customer-developed scripts to view the captured signal with the filters matched to your channel and media. Custom user scripts can be created in MATLAB, Visual Basic, Excel or other formats.
Exceptional Trigger and Sequence Performance
The DDA’s disk triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with up to 50 picosecond/sample time resolution. Up to 15,000 sectors of data can be gathered with the DDA 7 Zi analyzers. An optional capability, Streaming Sequence, uses the X-Stream II and the fast hardware architecture of the DDA to streamup to 300,000 segments of data to memory; all taken at a high trigger rate.
Natural Graphical Interface
One press on the DDA menu takes you directly to the Disk Drive Analyzer features. The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, react quickly to your commands. Functionality is exactly where you expect it to be.
The DDA 7 Zi provides one button access to all the tools needed to accurately debug and analyze disk drive operation.
The DDA 7 Zi features:
  • 31 custom parameters
  • 4 specific drive trigger
    • Sector
    • Servo Gate
    • PES trigger
    • Read Gate Trigger
  • Advanced drive analysis tools
Advanced Disk Drive analysis tools capabilities include:
  • Head Filter Equalizer emulation
  • Channel Emulation
  • SAM Histograms
  • Plot of SAM values
  • PES runout analysis
  • Analog Compare
Simultaneously connecting low-speed signals, like index and servo gate, and high-speed signals, like read channels has never been easier. With integrated 50 Ω and 1 MΩ inputs on all models, there is no longer a need for expensive adapters.
DDA 735Zi
Vertical System
Analog Bandwidth @ 50 Ω (-3 dB)
  3.5 GHz
Rise Time (typical)
  120 ps
Input Channels
  4
Bandwidth Limiters
  20 MHz, 200 MHz
Input Impedance
  50 Ω or 1 MΩ||15pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling
  1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage
  50 Ω: ±5 Vrms
Channel-Channel Isolation ProLink Input
  Not Applicable
Channel to Channel Isolation ProBus Input
  > 100:1 up to 2.5 GHz, > 30:1 from 2.5 GHz to 3.5 GHz
Vertical Resolution
  8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity
  50 O: 2 mV–1 V/div, fully variable (2-9.99 mV/div via zoom); 1 MO: 2 mV–10 V/div, fully variable
DC Gain Accuracy
  ±1.5% of full scale
Offset Range
  50 Ω:
Offset Accuracy
  ±(1.5% of full scale + 1.0% of offset value + 1 mV)

Horizontal System
Timebases
  Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range
  20 ps/div–1000 s/div (RIS mode: 20 ps/div - 10 ns/div; Roll mode: up to 1000 s/div)
Clock Accuracy
  < 1 ppm
Jitter Noise Floor
  800 fs (typical)
Trigger and Interpolator Jitter
  2 psrms (typical)
Sample Rate and Delay Time Accuracy
  < 0.06 / SR + (1 ppm * Reading) (rms)
Channel-Channel Deskew Range
  ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)
  10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output)
  10 MHz; 50 Ω impedance, output at the rear
External Sample Clock
  0.1 Hz-100 MHz, 50 Ω or 1 MΩ impedance, applied at the auxiliary input

Acquisition System
Single-Shot Sample Rate/Ch
  40 GS/s on 2 Ch
Random Interleaved Sampling (RIS)
  200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate
  1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time
  1 μs
Standard Memory (4 Ch / 2 Ch) (Number of Segments)
  20 M / 40 M
S - Memory Option
  32 M / 64 M
M - Memory Option
  64 M / 128 M
L - Memory Option
  128 M / 256 M

Acquisition Processing
Averaging
  Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)
  From 8.5 to 11 bits vertical resolution
Envelope (Extrema)
  Envelope, floor, or roof for up to 1 million sweeps
Interpolation
  Linear or Sin x/x

Triggering System
Modes
  Normal, Auto, Single, and Stop
Sources
  Any input channel, Aux, Aux/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode
  DC, AC, HFRej, LFRej
Pre-trigger Delay
  0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay
  0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or Events
  From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range
  ±5 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs
  2 div @ < 3.5 GHz
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs
  Not Applicable
External Trigger Sensitivity
  2 div @ < 1 GHz
External Trigger Input Range
  Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger
  2.0 GHz @ = 10 mV/div (minimum signal width setting 250 ps)

Basic Triggers
Edge/ Slope/ Line
  Triggers when signal meets slope (positive, negative, or either) and level condition.
TV-Composite Video
  Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).

SMART Triggers
State or Edge Qualified
  Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout
  Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern
  Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.

SMART Triggers with Exclusion Technology
Glitch
  Triggers on positive or negative glitches with widths selectable as low as 500 ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Width (Signal or Pattern)
  Triggers on positive or negative widths with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Interval (Signal or Pattern)
  Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)
  Triggers on any source if a given state (or transition edge) has occurred on another source.
Runt
  Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate
  Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
"A" Trigger List
  Edge, Window, Width, Glitch, Pattern, Pattern State, State, Dropout, Interval, Runt, Slew Rate, Serial Data (optional I2C, SPI, UART/RS-232, CAN, LIN, FlexRay)
"B" Trigger List
  Edge
Exclusion Triggering
  Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Holdoff Between Sequential Triggers
  Arming = Serial & Triggering = Anything, then min. time between events defined by serial pattern length

Cascade (Sequence) Triggering
Capability
  Arm on “A” event, then Trigger on “B” event. Or Arm on “A” event, then Qualify on “B” event, and Trigger on “C” event. Or Arm on “A” event, then Qualify on “B” then “C” event, and Trigger on “D” event
Types
  A or B event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog) C or D event: Edge or Pattern
Holdoff
  Delay between A and B, B and C, C and D, are all selectable by time or number of events
Reset
  Reset between A and B, B and C, C and D, are all selectable in time

High Speed Serial Protocol Triggering
Data Rates
  100 Mb/s - 1.25 Gb/s
Pattern Length
  80 bits, NRZ or 8b10b
Clock and Data Outputs
  400mVp-p (typical) AC coupled
Clock Recovery Jitter
  2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density (Typical)
Clock Recovery Tracking/ Acquisition Range
  50 Mb/s - 1.25 Gb/s
Hardware Clock Recovery Loop BW
  PLL Loop BW = Fbaud/5500, 100 Mb/s to 1.25 Gb/s (Typical)

Low Speed Serial Protocol Triggering (Optional)
Optionally available
  I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay

Color Waveform Display
Type
  Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution
  WXGA; 1280 x 768 pixels
Number of traces
  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles
  Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation
  Sample dots joined, or sample dots only

Internal Waveform Memory
Internal Waveform Memory
  4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.

WaveStream™ Fast Viewing Mode
Intensity
  256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels
  up to 4 simultaneously
Max Sampling Rate
  40 GS/s (20 GS/s for WavePro 710Zi without WPZi-1GHZ-4X20GS option)
Waveforms
  up to 2500 Waveforms/ second

Automatic Setup
Auto Setup
  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale
  Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range

Probes
Probes
  Qty. (4) ÷10 Passive Probes
Probe System: ProBus
  Probus (and ProLink on 4-6 GHz models). Automatically detects and supports a variety of compatible probes
Scale Factors
  Automatically or manually selected depending on probe used
Calibration Output
  1kHz square wave, 1Vp-p (typical), output to probe hook

Analog Persistence Display
Analog and Color-Graded Persistence
  Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection
  Activate persistence on all or any combination of traces
Sweep Display Modes
  All accumulated, or all accumulated with last trace highlighted
Persistence Types
  Select analog, color, or three-dimensional
Persistence Aging
  Select from 500 ms to infinity

Setup and Waveform Storage
Front Panel and Instrument Status
  Store to the internal hard drive or to a USB-connected peripheral device.

High Speed Digitizer Output (Option)
Type
  LeCroy LSIB
Transfer Rate
  Up to 325 MB/s (Typical)
Output Protocol
  PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol
  TCP/IP
Command Set
  Via Windows Automation, or via LeCroy Remote Command Set

Processor/CPU
Type
  Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory
  4 GB standard, up to 8 GB optional
Operating System
  Microsoft Windows® Vista Business Edition (64-bit) with SP1
Oscilloscope Operating Software
  Entire instrument including any installed optional applications packages operates within a single (X-Stream) Windows application
Real Time Clock
  Date and time displayed with waveform an in hardcopy files. SNTP support to synchronize to precision internal clocks.

Zoom Expansion Traces
Zoom Expansion Traces
  Display up to 4 Zoom and 8 Math/Zoom traces

Interface
Remote Control
  Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port (optional)
  Supports IEEE – 488.2
LSIB Port (optional)
  Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB Device Port (optional)
  Type-B
Ethernet Port
  Supports 10/100/1000 BaseT Ethernet interface (RJ45 port)
USB Ports
  minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port
  15-pin D-Type WXGA compatible to support customer-supplied external monitor. DVI connector to support LeCroy Zi-EXTDISP-15 additional touch screen display accessory. Includes support for extended desktop operation with optional LeCroy or other second monitor
Serial Port
  2 standard
Peripheral Bus
  LeCroy LBUS standard

Auxiliary Input
Signal Types
  Select External Trigger
Coupling
  50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage
  50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)

Auxiliary Output
Signal Types
  Select from calibrator, control signals or Off
Calibrator Signal
  5 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals
  Trigger enabled, trigger out, pass/fail status

General
Auto Calibration
  Ensures specified DC and timing accuracy is maintained for 1 year minimum.

Power Requirements
Voltage
  100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption
  850 W/850 VA

Environmental and Safety
Temperature (Operating)
  +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating)
  –20 °C to +60 °C
Humidity (Operating)
  5% to 80% relative humidity (non-condensing) up to +31 °C.
Humidity (Non-Operating)
  5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)
  Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)
  Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)
  0.5 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Random Vibration (Non-Operating)
  2.0 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Functional Shock
  20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total

Physical Dimensions
Dimensions (HWD)
  14"H x 18.4"W x 11.4"D (355 x 467 x 289 mm)
Weight
  39.5 lbs. (18 kg)
Shipping Weight
  28.2 kg; 62 lbs.

Certifications
Certifications
  CE Compliant, UL and cUL listed; conforms to EN 61326-1, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04

Warranty and Service
Warranty and Service
  3-year warranty; calibration recommended annually.

DDA 760Zi
Vertical System
Analog Bandwidth @ 50 Ω (-3 dB)
  6 GHz
Rise Time (typical)
  70 ps
Input Channels
  4
Bandwidth Limiters
  20 MHz, 200 MHz
Input Impedance
  50 Ω or 1 MΩ||15pF, 10 MΩ || 11 pF with supplied Probe
Input Coupling
  1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Maximum Input Voltage
  50 Ω (ProBus): ±5 Vrms
Channel-Channel Isolation ProLink Input
  > 200:1 up to 2 GHz, > 50:1 from 2 GHz to 4 GHz, > 20:1 from 4 GHz to 6 GHz
Channel to Channel Isolation ProBus Input
  > 100:1 up to 2.5 GHz, > 30:1 from 2.5 GHz to 3.5 GHz
Vertical Resolution
  8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity
  50 Ω: 2 mV–1 V/div, fully variable (2-9.99 mV/div via zoom); 1 MΩ: 2 mV–10 V/div, fully variable
DC Gain Accuracy
  ±1.5% of full scale
Offset Range
  50 Ω:
Offset Accuracy
  ±(1.5% of full scale + 1.0% of offset value + 1 mV)

Horizontal System
Timebases
  Internal timebase common to 4 input channels; an external clock may be applied at the auxiliary input
Time/Division Range
  20 ps/div–1000 s/div (RIS mode: 20 ps/div - 10 ns/div; Roll mode: up to 1000 s/div)
Clock Accuracy
  < 1 ppm
Jitter Noise Floor
  560 fs (typical)
Trigger and Interpolator Jitter
  1 psrms (typical)
Sample Rate and Delay Time Accuracy
  < 0.06 / SR + (1 ppm * Reading) (rms)
Channel-Channel Deskew Range
  ±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)
  10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output)
  10 MHz; 50 Ω impedance, output at the rear
External Sample Clock
  0.1 Hz-100 MHz, 50 Ω or 1 MΩ impedance, applied at the auxiliary input

Acquisition System
Single-Shot Sample Rate/Ch
  40 GS/s on 2 Ch
Random Interleaved Sampling (RIS)
  200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Maximum Trigger Rate
  1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time
  1 μs
Standard Memory (4 Ch / 2 Ch) (Number of Segments)
  20 M / 40 M
S - Memory Option
  32 M / 64 M
M - Memory Option
  64 M / 128 M
L - Memory Option
  128 M / 256 M

Acquisition Processing
Averaging
  Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)
  From 8.5 to 11 bits vertical resolution
Envelope (Extrema)
  Envelope, floor, or roof for up to 1 million sweeps
Interpolation
  Linear or Sin x/x

Triggering System
Modes
  Normal, Auto, Single, and Stop
Sources
  Any input channel, Aux, Aux/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode
  DC, AC, HFRej, LFRej
Pre-trigger Delay
  0–100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay
  0–10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off by Time or Events
  From 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range
  ±5 div from center
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProBus Inputs
  2 div @ < 3.5 GHz
Trigger Sensitivity with Edge Trigger (Ch 1–4) ProLink Inputs
  2 div @ < 6 GHz
External Trigger Sensitivity
  2 div @ < 1 GHz
External Trigger Input Range
  Aux (±0.4 V); Aux/10 (±4 V)
Max. Trigger Frequency, SMART Trigger
  2.0 GHz @ = 10 mV/div

Basic Triggers
Edge/ Slope/ Line
  Triggers when signal meets slope (positive, negative, or either) and level condition.
TV-Composite Video
  Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).

SMART Triggers
State or Edge Qualified
  Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout
  Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Pattern
  Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.

SMART Triggers with Exclusion Technology
Glitch
  Triggers on positive or negative glitches with widths selectable as low as 500 ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Width (Signal or Pattern)
  Triggers on positive or negative widths with widths selectable as low as 200ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults.
Interval (Signal or Pattern)
  Triggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)
  Triggers on any source if a given state (or transition edge) has occurred on another source.
Runt
  Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate
  Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
"A" Trigger List
  Edge, Window, Width, Glitch, Pattern, Pattern State, State, Dropout, Interval, Runt, Slew Rate, Serial Data (optional I2C, SPI, UART/RS-232, CAN, LIN, FlexRay)
"B" Trigger List
  Edge
Exclusion Triggering
  Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Holdoff Between Sequential Triggers
  Arming = Serial & Triggering = Anything, then min. time between events defined by serial pattern length

Cascade (Sequence) Triggering
Capability
  Arm on “A” event, then Trigger on “B” event. Or Arm on “A” event, then Qualify on “B” event, and Trigger on “C” event. Or Arm on “A” event, then Qualify on “B” then “C” event, and Trigger on “D” event
Types
  A or B event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, or Pattern (analog) C or D event: Edge or Pattern
Holdoff
  Delay between A and B, B and C, C and D, are all selectable by time or number of events
Reset
  Reset between A and B, B and C, C and D, are all selectable in time

High Speed Serial Protocol Triggering
Data Rates
  100 Mb/s - 3.125 Gb/s
Pattern Length
  80 bits, NRZ or 8b10b
Clock and Data Outputs
  400mVp-p (typical) AC coupled
Clock Recovery Jitter
  2 ps rms + 0.3% Unit Interval rms for PRBS data patterns with 50% transition density (Typical)
Clock Recovery Tracking/ Acquisition Range
  50 Mb/s - 2.7 Gb/s
Hardware Clock Recovery Loop BW
  PLL Loop BW = Fbaud/5500, 100 Mb/s to 1.25 Gb/s (Typical)

Low Speed Serial Protocol Triggering (Optional)
Optionally available
  I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay

Color Waveform Display
Type
  Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution
  WXGA; 1280 x 768 pixels
Number of traces
  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles
  Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation
  Sample dots joined, or sample dots only

Internal Waveform Memory
Internal Waveform Memory
  4 active waveform memory traces (M1-M4) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.

WaveStream™ Fast Viewing Mode
Intensity
  256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channels
  up to 4 simultaneously
Max Sampling Rate
  40 GS/s (20 GS/s for WavePro 710Zi without WPZi-1GHZ-4X20GS option)
Waveforms
  up to 2500 Waveforms/ second

Automatic Setup
Auto Setup
  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale
  Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range

Probes
Probes
  Qty. (4) ÷10 Passive Probes
Probe System: ProBus
  Probus (and ProLink on 4-6 GHz models). Automatically detects and supports a variety of compatible probes
Scale Factors
  Automatically or manually selected depending on probe used
Calibration Output
  1kHz square wave, 1Vp-p (typical), output to probe hook

Analog Persistence Display
Analog and Color-Graded Persistence
  Variable saturation levels; stores each trace’s persistence data in memory
Trace Selection
  Activate persistence on all or any combination of traces
Sweep Display Modes
  All accumulated, or all accumulated with last trace highlighted
Persistence Types
  Select analog, color, or three-dimensional
Persistence Aging
  Select from 500 ms to infinity

Setup and Waveform Storage
Front Panel and Instrument Status
  Store to the internal hard drive or to a USB-connected peripheral device.

High Speed Digitizer Output (Option)
Type
  LeCroy LSIB
Transfer Rate
  Up to 325 MB/s (Typical)
Output Protocol
  PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol
  TCP/IP
Command Set
  Via Windows Automation, or via LeCroy Remote Command Set

Processor/CPU
Type
  Intel® CoreTM 2 Quad, 2.5 GHz (or better)
Processor Memory
  4 GB standard, up to 8 GB optional
Operating System
  Microsoft Windows® Vista Business Edition (64-bit) with SP1
Oscilloscope Operating Software
  Entire instrument including any installed optional applications packages operates within a single (X-Stream) Windows application
Real Time Clock
  Date and time displayed with waveform an in hardcopy files. SNTP support to synchronize to precision internal clocks.

Zoom Expansion Traces
Zoom Expansion Traces
  Display up to 4 Zoom and 8 Math/Zoom traces

Interface
Remote Control
  Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port (optional)
  Supports IEEE – 488.2
LSIB Port (optional)
  Supports PCIe Gen1 x4 protocol with LeCroy supplied API
USB Device Port (optional)
  Type-B
Ethernet Port
  Supports 10/100/1000 BaseT Ethernet interface (RJ45 port)
USB Ports
  minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
External Monitor Port
  15-pin D-Type WXGA compatible to support customer-supplied external monitor. DVI connector to support LeCroy Zi-EXTDISP-15 additional touch screen display accessory. Includes support for extended desktop operation with optional LeCroy or other second monitor
Serial Port
  2 standard
Peripheral Bus
  LeCroy LBUS standard

Auxiliary Input
Signal Types
  Select External Trigger
Coupling
  50 Ω: DC; 1 MO: AC, DC, GND
Max. Input Voltage
  50 Ω: 5 Vrms; 1 MO: 250 V (Peak AC < 10 kHz + DC)

Auxiliary Output
Signal Types
  Select from calibrator, control signals or Off
Calibrator Signal
  5 Hz–5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0–1 V into 1 MΩ)
Control Signals
  Trigger enabled, trigger out, pass/fail status

General
Auto Calibration
  Ensures specified DC and timing accuracy is maintained for 1 year minimum.

Power Requirements
Voltage
  100–240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection
Max. Power Consumption
  850 W/850 VA

Environmental and Safety
Temperature (Operating)
  +5 °C to +40 °C including CD-RW/DVD-ROM drive
Temperature (Non-Operating)
  –20 °C to +60 °C
Humidity (Operating)
  5% to 80% relative humidity (non-condensing) up to +31 °C.
Humidity (Non-Operating)
  5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)
  Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)
  Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)
  0.5 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Random Vibration (Non-Operating)
  2.0 grms overall level, 5 Hz to 500 Hz, 10 minutes in each of three orthogonal axes, 30 minutes total
Functional Shock
  20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total

Physical Dimensions
Dimensions (HWD)
  14"H x 18.4"W x 11.4"D (355 x 467 x 289 mm)
Weight
  39.5 lbs. (18 kg)
Shipping Weight
  28.2 kg; 62 lbs.

Certifications
Certifications
  CE Compliant, UL and cUL listed; conforms to EN 61326-1, EN 61010-1, UL 61010-1 2nd edition, and CSA C22.2 No. 61010-1-04

Warranty and Service
Warranty and Service
  3-year warranty; calibration recommended annually.

Memory Options
DDAZi-L-128128 Mpt/Ch (256 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 4 GB of RAM (8 GB total)
DDAZi-M-6464 Mpt/Ch (128 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 4 GB of RAM (8 GB total)
DDAZi-S-32 32 Mpt/Ch (64 Mpt/Ch Interleaved) Memory Option for DDA Zi. Includes an additional 2 GB of RAM (4 GB total)
Serial Trigger and Decode
WPZi-FlexrayBus TDFlexRay Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-FlexRayBus TDPFlexRay Bus Trigger, Decode, and Physical Layer Test Option for WavePro Zi Series Oscilloscopes
WPZi-HSPT50 Mb/s to 3.125 Gb/s High Speed Serial Trigger Option for 4-6 GHz Oscilloscopes & Disk Drive Analyzers
WPZi-I2Cbus TDI2C Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-LINbus TDLIN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-MSPT50 Mb/s to 1.25 Gb/s Medium Speed Serial Trigger Option for 2.5-3.5 GHz Oscilloscopes & Disk Drive Analyzers
WPZi-SPIbus TDSPI Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-UART-RS232bus TDUART and RS232 Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
Serial Data Communications Testing Software
QPHY-ENETQualiPHY Ethernet Application Software
QPHY-HDMIQualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option)
QPHY-PCIePCIe Gen1 Compliance and Development Software
QPHY-SATAQualiPHY Enabled SATA Software Option
QPHY-USBUSB Application Software Package
QPHY-UWBWiMedia UWB Transmitter Measurement Software Option
General Purpose Software
WPZi-AORMAdvanced Optical Recording Measurement Package for WavePro Zi Series
WPZi-EMCEMC Pulse Parameter Software Package for WavePro Zi Series
WPZi-EYEDRIIEye Doctor II Advanced Signal Integrity Tools for WavePro 7 Zi Oscilloscopes, SDA 7 Zi Serial Data Analyzers, and DDA 7 Zi Disk Drive Analyzers
WPZi-SPECTRUMSpectrum Analyzer and Advanced FFT Option for WavePro Zi Series
WPZi-XDEVDeveloper's Tool Kit Option for WavePro Zi Series
Digital Filtering Software
WPZi-DFP2Digital Filter Software Package for WavePro Zi Series
Jitter Analysis Software
WPZi-JTA2Jitter Timing and Analysis Software Package for WavePro Zi Series
CAN Bus Testing
WPZi-CANbus TDCAN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes
WPZi-CANbus TDMCAN Bus Trigger, Decode, and Measure Option for WavePro Zi Series Oscilloscopes
Mixed Signal Test Solutions
MS-250250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option
MS-500500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option
MS-500-36250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option
MSO-DLS-18Digital Lead Set, D0-D17
MSO-DLS-36Digital Lead Set, D18-D35
MSO-GND-EXTENDMSO Ground Extenders
MSO-GND-LEADMSO Flying Ground Lead
MSO-LBUSLeCroy Bus Cable
MSO-MICTORMictor Cable, D0-D35
Communications Testing Fixtures
TF-DSQProbe Deskew and Calibration Fixture
TF-ENET-B10/100/1000Base-T Compliance Test Fixture
TF-ETTelecom Adaptor Kit 100Ω, 120Ω, 75Ω
TF-HDMI-3.3V-QUADPAKHDMI Pull-Up Terminator Quad Pack – for Use with the Efficere ET-HDMI-TPS-S Test Fixture
TF-SATA-CSATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-SATA-C-KitSATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required)
TF-USB-BUSB 2.0 Testing Compliance Test Fixture
Differential Amplifiers
DA1855ADA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR22 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters
DA1855A-PR2-RMRack mountable version of the DA1855A-PR2
Storage Devices
GPIB-2GPIB Option for LeCroy oscilloscope. Half-height card with custom connector.
LSIB-1High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector
WPZi-2-UPG-8GBRAMUpgrade from 2 GB to 8 GB CPU RAM
WPZi-200GB-HDUpgrade from standard size hard drive to 200 GB hard drive
WPZi-200GB-RHD-02Additional 200 GB Hard Drive for WPZi. Includes Windows Vista OS, LeCroy oscilloscope software and critical scope operational file duplicates.
WPZi-4-UPG-8GBRAMUpgrade from 4 GB to 8 GB CPU RAM
Miscellaneous Accessories
FRONT-COVER-1Replacement Protective Front Cover for WavePro Zi Series
KYBD-1Keyboard
LSIB-CABLE-3MPCI Express x 4 3-meter cable with x4 cable connectors included
LSIB-CABLE-7MPCI Express x 4 7-meter cable with x4 cable connectors include
LSIB-HOSTBOARDPCI Express x4 Host Interface Board for desktop PC
LSIB-HOSTCARDPCI Express x1 Express Card Host Interface for laptop Express Card slot
POUCH-1Replacement Accessory Pouch
Rackmounts, Carts and Cases
OC1021OC1021 scope cart is sturdy and mobile
OC1024OC1024 scope cart is sturdy and mobile
RACKMOUNT-1Rack-mount accessory for converting a WavePro Zi series oscilloscope to an 8U rack-mounted package
WPZi-HARDCASEHard carrying case for all WavePro Zi Series oscilloscopes
WPZi-SOFTCASESoft carrying case for all WavePro Zi Series oscilloscopes
Warranty & Calibration
WPZi-C5Five Year NIST Calibration
WPZi-C5/MILFive Year MIL Calibration
WPZi-CCNIST Traceable Calibration
WPZi-CCMMIL STD Calibration
WPZi-CCMILMIL Std. Traceable Calibration
WPZi-EW1 Year Extended Warranty
WPZi-EW22 Year Extended Warranty
WPZi-T5Five Year Warranty & NIST Calibration
WPZi-T5/MILFive Year Warranty & MIL Calibration
Differential Probes
ADP300High-Voltage Active Differential Probe
ADP305High-Voltage Differential Probes From LeCroy
AP03115 MHz Differential Probe
AP033500 MHz Active Differential Probe
AP0341 GHz Active Differential Probe
D300A-ATWaveLink 4 GHz Differential Probe with Adjustable Tip Module
D310WaveLink 3.5 GHz Differential probe module 2.5V
D320WaveLink 3.5 GHz Differential probe module 5V
D350STWaveLink 4 GHz, 5 V Differential with Small Tip Module
D500PTWaveLink 6 GHz Differential Positioner Mounted Tip Module
D600A-ATWaveLink 7.5 GHz Differential Probe with Adjustable Tip Module
D600STWaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP)
D610WaveLink 6 GHz Differential probe module 2.5V
D620WaveLink 6 GHz Differential probe module 5V
Dx10-PTReplacement Dx10-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
Dx20-PTReplacement Dx20-PT Tip with Qty. 4 Pogo Pin Tips and Qty. 2 Sockets
WL-PbusWaveLink ProBus probe body = 3.5 GHz
WL-PLinkWaveLink ProLink probe body >3.5 GHz
WL300WaveLink ProBus Probe Body
WL600WaveLink ProLink Probe Body
Active Voltage Probes
HFP25002.5 GHz Active Voltage Probe
Current Probes
AP01530 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse
CP03030 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP03130 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP150150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP500500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak
High Voltage Probes
PPE1.2KV10:1/100:1 200/300 MHz 5M Ohm/100M Ohm
PPE20KV1000:1 100 MHz 100M Ohm High-Voltage Probe
PPE2KV100:1 400 MHz 100M Ohm High Voltage Probe
PPE4KV100:1 400 MHz 100M Ohm High-Voltage Probe
PPE5KV100:1 400 MHz 100M Ohm High-Voltage Probe
PPE6KV1000:1 400 MHz 5M Ohm High-Voltage Probe
Passive Probes
PP007-WR-1Passive Probe, 500 MHz, 2.5mm tip
PP011-1PP011 Passive Probe
ZS Series High Impedance Active Probes
ZS10001 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1000-QUADPAKSet of 4 ZS1000 Active Probes
ZS15001.5 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1500-QUADPAKSet of 4 ZS1500 Active Probes
Optical to Electrical Converters
OE425Short wavelength O/E Converter (500-870 nm)
OE455Long wavelength O/E Converter (950-1630 nm)
OE525Short wavelength O/E Converter (500-870 nm)
OE555Long wavelength O/E converter
Probe Adapters
LPA-SMA-APro-Link to SMA Adapter, new style
LPA-SMA-KIT-AKit of Pro-Link to SMA Adapter, new style
Probe Parts and Kits
Dx10-QCReplacement Quick Connect lead set for D310/D610
Dx10-SIReplacement Solder tip lead set for D310/D610
Dx10-SPReplacement Square Pin lead set for D310/D610
Dx20-QCReplacement Quick Connect lead set for D320/D620
Dx20-SIReplacement Solder tip lead set for D320/D620
Dx20-SPReplacement Square Pin lead set for D320/D620
Product Resources
Downloads
Additional Resources