Eye Doctor™
|

Vitrual Probing™ and equalizer emulation enhance the capability of the SDA to allow the measurement of serial data signals in equalized systems
|
- Full signal integrity analysis of equalized receiver signal
- Real time co-simulation of measured signals and measured or modeled network characteristics
- Evaluate performance margins in equalized systems
- De-embedding of fixture and probe responses
- High accuracy far-end channel measurements
- Emulates any combination of DFE and FFE equalizers
- Automatic equalizer coefficient optimization
- Direct entry of FFE and DFE coefficients
|
As the symbol rates of systems
have increased, the measurement
challenges have also and with the
adoption of receiver equalization,
traditional jitter and noise measurements
are becoming inadequate
for determining interoperability.
Eye Doctor is a DSO-based
instrumentation and simulation
system which addresses these
measurement challenges and is
a dramatic leap in interoperability
and compliance testing capability.
Eye Doctor provides the tools to
undo or compensate many common
forms of distortion thereby increasing
signal to noise, opening eyes,
increasing rise time, reducing jitter
restoring lost bandwidth and improving
waveform fidelity.
Measuring Equalized
Systems
Imperfections such as through
holes, connectors, vias and package
pins cause distortions in the high
frequency content of high bit rate
signals. The resulting eye is often
closed or nearly closed. The traditional
approach to interoperability
testing involves measuring the
channel response and the transmitter
signal quality against compliance
masks designed so that the signal
eye and jitter will enable error-free
operation. In an equalized system,
the channel, transmitter and receiver
are closely coupled and interoperability
is determined by whether the
signal can be equalized. What is
needed is a method to quantitatively
measure the interoperability of
these systems.
Current generation serial data systems ensure interoperability using compliance measurements. Next generation systems employing
equalization require new methods for determining interoperability. With the signal eye closed, traditional compliance measurements
are no longer sufficient.
Eye Doctor
Eye doctor consists of two
elements; Virtual Probing and
equalized receiver emulation.
Virtual Probing enhances the
accuracy of measurements
made on distorted waveforms
while equalized receiver emulation
allows measurements to be made
from a "receivers eye view."
The ideal view of the signal within
the receiver allows accurate total
jitter and bit error rate measurements
that are representative of actual
system performance.
Virtual Probing
Probes and fixtures are not perfect
and their presence in the circuit
impacts both the loading on the
DUT as well as the waveform seen
by the oscilloscope. Virtual Probing
is a powerful signal processing tool
which enables the user to measure
a signal anywhere within a system
and then project a response at any
other desired point. This feature
works by using S-parameter files
of the various components in the
system to derive a filter which
relates the desired measured signal
to the acquired waveform. For
example, measurements can be
made where the cleanest signal is
available, usually at the transmitter,
and the corrupted signal at the
far-end of the channel (at the end
of the backplane) can be simulated
thus eliminating probe and instrument
noise from the measurement.
The derived filter takes into account
all of the interactions among the
elements of the system and transmitter
signal including differential
to common mode conversion, nearend
and far-end crosstalk.
Virtual Probing can be used to
de-embed probe and fixture responses
from measurements thereby improving
the accuracy of signal integrity
measurements.
Equalizer emulation simulates the signal as viewed within the receiver.
The component can automatically determine the optimum weighting
coefficients for both FFE and DFE with the number of taps for each
selected by the user. Coefficients can also be entered directly. The full
jitter analysis capability of the SDA is available on the equalized signal.
Equalizer Emulation
Eye Doctor features equalized receiver
emulation which includes both Feed
Forward Equalization (FFE) and Decision
Feedback Equalization (DFE) along with
clock recovery and a variable decision
threshold. This ideal receiver reveals
the signal as seen within a real receiver
at the detector where it is impossible
to probe. The equalized signal can be
measured using the powerful jitter and
signal analysis software in the SDA
allowing the bit error rate, total jitter,
and eye opening to be measured thus
giving a precise indication of the
performance margin. Because the
receiver emulation is ideal, the margins
are measured independently of measurement
system and receiver noise.
Specifications
Equalizer Emulation
- Up to 20 tap linear tapped delay line equalizer
(transversal filter).
- PLL for clock recovery with variable loop bandwidth.
- Up to 20 tap Decision Feedback Equalizer (DFE)
including erasure DFE.
- Clock skew adjustment.
- Outputs for equalized waveform (slicer input),
data waveform (slicer output), and recovered clock.
- Error waveform output for user defined equalizer
optimizations.
- Automatic blind adaptation using built-in LMS
algorithms.
- Multi-level detection threshold supports duobinary
and multilevel signaling systems.
Virtual Probing
- Provides waveforms that compensate for probe loading
effects within bandwidth limitations of the system.
- Produces linear filters that operate on up to 8 inputs
and provides up to 8 outputs.
- Simple text file system description similar to Spice.
- Accepts Touchstone format S-parameter file network
device descriptions
- Includes simple device descriptions such as ideal tees,
power splitter, open, short, thru plus lumped elements
such as resistors, capacitors and inductors
Ordering Information
Eye Doctor is optional on the Following SDA and WaveExpert Models
- Serial Data Analyzers SDA 6000A, SDA 6020, SDA 9000,
SDA 13000, SDA 11000, SDA 18000
- SDA 100G, NRO 9000 and WaveExpert 100H
| Product Description |
Product Code |
| Eye Doctor (Virtual probe and equalizer emulation bundle) |
EYEDR |
| Virtual Probe |
EYEDR-VP |
| Equalizer Emulation |
EYEDR-EQ |
| Retrofit Kit for Eye Doctor (Virtual probe and equalizer emulation bundle) |
RK-EYEDR |
| Retrofit Kit for Virtual Probe |
RK-EYEDR-VP |
| Retrofit Kit for Equalizer Emulation |
RK-EYEDR-EQ |
|
|
|