LA302 - 100 MHz
LA303 - 200 MHz

Main Features

  • 100 & 200 MHz

  • 2 + 1 Channels

  • Sensitivity of 2 mV/div max

  • Max Sweep Speed of 1 ns/div

  • High-Speed Auto Setup

  • Cursor Measurements

  • Full TV Trigger with Field & Line Selection

  • Save and Recall Panel Settings

  • Frequency Counter

  • High-Intensity CRT

With three channels and up to 200 MHz bandwidth, the LA302 and LA303 analog oscilloscopes offer a high level of performance for relatively low cost. 

Analog oscilloscopes offer unique benefits in solving specific measurement problems. The analog display provides important clues about the relative frequency content of signals mixed together or the occurrence of low rep-rate events on repetitive signals. The analog display effectively displays these "grey scaling" and "persistence" effects. The ultra fast display update rate lets you see how the waveforms behave in real time. 

The LA302 and LA303 are perfect instruments for service and educational applications. Equipped with extensive TV triggering, both scopes are excellent for video testing. 

The standard multipurpose trigger, five-digit counter, and comprehensive cursors make the LA302 and LA303 truly universal oscilloscopes.

View Dimension Drawings

Features

Convenient fine-adjustment mode

Pressing FINE and turning the knob enables slow scrolling of waveforms ­ a function comparable to a digital storage scope's roll mode.

Line triggering provided for AC line measurement

AC line-related measurement of various frequencies can be obtained.

Third channel input

CH3 provides three sensitivity levels for a wider range of measurements.

Input with probe sensor function

When using a probe, the range display is automatically calibrated by detecting 10:1 or 100:1 with the probe sensor.

Specifications

Model LA302 Model LA303
Display CRT: 6-inch rectangular, internal graticule (8 x 10 div with scale illumination), meshless CRT
Accelerating voltage:   Nominal 16 kV

 

Vertical Deflection System
Mode:   CH1, CH2, CH3, ADD, ALT, CHOP
Frequency Response: 5 mV/div - 5 V/div, DC ­ 100 MHz; 2 mV/div, DC ­ 50 MHz 5 mV/div - 5 V/div, DC ­ 200 MHz;
2 mV/div, DC ­ 50 MHz
Accuracy ±2%
Bandwidth Limiter:   20 MHz
Risetime: 3.5 ns or less 1.75 ns or less
Signal Delay Time:   At least 30 ns
Input RC Direct:   1 MOhm ±1.5% // 20 pF ±2 pF
Input RC with Probe:   10 MOhm ±3% // 12.5 pF ±2 pF
Max. Input:   Direct, ±400 V max, with 10:1 probe, ±600 V max
Polarity Switching:  
Possible only for CH2
Channel 1 & 2
Sensitivity:   2 mV/div - 5 V/div, 11 step (1-2-5); 2 mV/div - 12.5 V/div (with vernier)
Input Coupling:   AC, DC, GND (The lowest usable frequency is 4 Hz with AC coupling.)
Channel 3
Sensitivity:   50 mV/div, 100 mV/div, 500 mV/div, ±2%
Input Coupling:   AC, DC
Triggering
A Triggering
   Sources: CH1, CH2, CH3, LINE
  Coupling: AC, DC, HF-REJ, LF-REJ
B Triggering
   Sources: CH1, CH2, CH3
  Coupling: AC, DC, HF-REJ, LF-REJ
TV Triggering: ODD, EVEN, BOTH, line selection, TV system (NTSC, PAL/SECAM [HDTV optional in LA302, standard in LA303])
Trigger Sensitivity DC - 10 MHz, 0.4 div
10 - 100 MHz, 1.0 div
DC - 10 MHz, 0.4 div
10 - 100 MHz, 1.0 div
100 - 200 MHz, 1.5 div

X-Y Operation

X-axis: Sensitivity, same as CH1; accuracy, ±3%; bandwidth, DC - 2 MHz

Y-axis: CH1, CH2, CH3, ADD

Horizontal Deflection System

Horizontal Display A, ALT, B, X-Y

Mode AUTO, NORM, SINGLE

A sweep
Model LA302
Sweep time: Fastest range, 20 ns/div; slowest range, 500 ms/div

Model LA303
Sweep time: Fastest range, 10 ns/div (1-2-5 step); slowest range, 500 ms/div

B sweep
Model LA302
Sweep time: Fastest range, 20 ns/div; slowest range, 5 ms/div; accuracy A/B, ±2%

Model LA303
Sweep time: Fastest range, 10 ns/div (1-2-5 step); slowest range, 5 ms/div; accuracy A/B, ±2%

Magnifier: 10 times

Accuracy: ±3%

Model LA302
Fastest Range:
2 ns/div

Model LA303
Fastest Range: 1 ns/div

Delay Jitter: 1/20,000

Hold-off Time: Variable (up to sweep length or longer)

Auto Setup

Input Channel: CH1, CH2

Frequency Response: 50 Hz ­ 50 MHz

CH2 Signal Output

(factory option)

Model LA302

DC ­ 50 MHz

Model LA303

DC ­ 100 MHz

EXT Z-axis Input

(factory option)

0.5 Vp-p

Utilities

Calibrator

Waveform: Square-wave, 1 kHz ±0.1%, 0.6 Vp-p ±1%

CTR Readout

Readout: Attenuator range, ADD, UNCAL, AC/DC/GND, vertical mode, CH2 polarity, A/B sweep range, x10 MAG, UNCAL, horizontal display mode, hold-off, trigger coupling, trigger source, trig slope, TV-field, TV-line, TV-system (NTSC, PAL/SECAM [HDTV in LA303])

Cursor Measurement

Time difference: DeltaT

Voltage difference: DeltaV

Division Calculation by DeltaT: 1/DeltaT

Frequency Counter

Display digits: 5 digits, decimal

Accuracy: ±0.01%

Model LA302
Frequency measurement range:
2 Hz - 100 MHz (option six digit)

Model LA303
Frequency measurement range:
2 Hz - 200 MHz, reciprocal (option six digit)

Save/Recall Function

Number of Panel Setups:
Model LA302 and LA303
32 max

Model LA302P
255 in banks of 63

Back-up: Battery back-up (approx. 30,000 hr)

Power Supply

Voltage range: AC 90 V - 132 V/ 180 V - 250 V

Frequency range: 48 Hz - 440 Hz

Power consumption: 110 VA max

Dimensions and Weight

Dimensions: 272W x 152H x 410L mm

Weight: approx. 7.5 kg (w/o access)

Environmental Conditions

Operating: 0°C ­ +40°C, 90% RH (40°C)

Performance Guarantee: +10°C ­ +35°C

 



Copyright © LeCroy Corporation 2008