DXC300 & DXC350
Main
Features
-
DC
to 100 MHz with DA1855A
DC to 10 MHz with DA1822A
-
Max
Input Voltage
500 V (DXC300), 400 V (DXC350)
-
High
Input Impedance
92 || MOhms 4.5pF (DXC 300), 92 MOhms
||
2.7pF (DXC350)
-
1.2
Meter Cable Length
The
DXC300 and DXC350 are high-impedance probes matched for
differential measurement applications. They are designed to
minimize circuit loading to a level similar to that of an FET
probe, while still retaining all the versatility and
ruggedness of a passive differential probe. They are ideal for
probing in sensitive circuits where probe loading is a
problem. They extend the DA1800 series amplifier's signal
range (both differential and common mode) to ±500 or ±400
volts. Models DA1855 and DA1822 differential amplifiers
automatically account for the probe's attenuation factor in
their effective gain displays and the location of the decimal
in the precision voltage generator display.
Specifications
|
|
DXC300
|
DXC350
|
|
Attenuation
factor:
|
100
|
100
|
|
Bandwith(-3dB):
|
w/
DA1855A |
100
MHZ
|
100MHz
|
|
|
w/
DA1822A |
10
MHz
|
10MHz
|
|
Risetime:
|
w/
DA1855A |
3.5
ns
|
3.5
ns
|
|
|
w/
DA1822A |
35
ns
|
35
ns
|
|
Input
Resistance:
|
92
M(ohm)
|
92
M(ohm)
|
|
Input
Capacitance:
|
4.5
pF
|
2.4
pF
|
|
Maximum
non-destructive Input Voltage
|
±500V
|
±400V
|
|
Length:
|
1.2
Meter
|
1.2
Meter
|
| Environmental
Characteristics |
| Operating
Range: |
0° to 50°C |
|
Non-Operating: |
-4° to 75°C |
| Physical
Characteristics |
|
Weight:
|
0.21 kg (0.47 lb) |
|
Shipping Weight:
|
0.45 kg (1 lb) |
| Warranty: |
1 year |
Order
Information

| Model |
Description |
DXC200 |
1:1,
50 MHz Passive Differential Probe Pair |
DXC100A |
100:1
or 10:1 Selectable 250 MHz Passive Differential Probe
Pair |
DXC5100 |
100:1,
250 MHz, 2.5kV High Voltage Probe Pair |
DA101 |
10:1,
1 MOhm Passive Attenuator |
DA18XX-RM01 |
Rackmount
Adapter for DA18XX-PR2, Size (2U) |
| |
| To
view a list of DISCONTINUED PRODUCTS click this link. |
|
|