SOLUTIONS

Automotive/Vehicle Test
Data Storage
Embedded Controller Test
Jitter/Timing
Power Measurement
Serial Data Analysis
Beta Program
    
    

DDA5005A and DDA5005AXXL
Disk Drive Analyzers

Accurately capture and analyze many sectors, or a complete track for read channel design or head/media evaluation.

Leading Features
  • 5 GHz bandwidth
     
  • 10 GS/s sample rate/channel
     
  • 20 GS/s dual-channel mode
     
  • Up to 100 Mpts in dual-channel mode
     
  • 5 GHz trigger bandwidth
     
  • Intuitive front panel and touch screen interface
     
  • Zoom and Multi-Zoom on disk sectors
     
  • One-button access to Read Channel Emulation, Servo Analysis, Disk Triggers
     
  • Head Equalization, Channel Emulation and SAM Histograms
     
  • Segmented Memory for sector-by-sector parametric analysis
     
  • Built in PWxx, amplitude, pulseshape and ACSN parametric measurements
     
  • Customizable with MATLAB scripts
     
  • Flexible connectivity to networks, peripherals with 100Base-T Ethernet and USB

Maximum Performance
The Disk Drive Analyzer 5005A, with 5 GHz bandwidth, includes LeCroy’s newest and most powerful Disk Drive Analysis toolset. Capture, view, and analyze the waveshape of high-speed, complex drive signals with speed and integrity.

LeCroy’s X-Stream architecture integrates SiGe “digitizer on a chip“ technology and a specialized high-speed streaming bus design to transfer data from the ADC to a proprietary acquisition memory. The X-Stream architecture enables disk drive engineers to quickly and easily measure and analyze disk drive signals. With 10 GS/s and 24 Mpts/Ch—up to 20 GS/s and 48 Mpts on two channels—you can be assured drive signals are captured with accuracy and precision.

The DDA 5005A is designed for signal fidelity, whole track acquisition and analysis for read channel, media noise analysis, and head parametrics, with the longest acquisition memory standard. The DDA 5005A comes standard with enough acquisition memory to capture 2.4 milliseconds of data at 20 GS/s, while the XXL model captures 5 milliseconds with its 100 Mpts per dual-channel memory.

Excellence in Head,Disk,Track, and Noise Analysis
The DDA series analyzers incorporate the tools to make you most efficient. The standard 100 Mpts of capture memory in the DDA 5005A XXL provides 5 milliseconds of single-shot, 20 GS/s capture speed on two channels.

Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 5 GHz and then QuickZoom from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple Zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. You can measure the time between two events accurately with horizontal and vertical cursors. Disk drive parameters let you characterize the pulse width variation or signal-to-noise ratio across a selectable region. Failure Analysis Engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good signals. Analog-to-digital converters running at speeds up to 20 GS/second ensure the right oversampling rate to measure today’s high-speed read channels. In every DDA,you can run your MATLAB scripts to view the captured signal, with the filters matched to your channel and media.


WaveLink high bandwidth differential probes let you
capture head signals with best signal to noise ratio.

 
Triggers Designed for Drive Analysis

Disk Triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with 50 or 100 picosecond/sample time resolution. Up to 20,000 sectors of data can be gathered with a DDA 5005A equipped with the DDA-XXL option.

Natural Graphical Interface
One press of the DDA button takes you directly to the Disk Drive Analyzer features.The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, reacts quickly to your commands. Functionality is exactly where you expect it to be. If you have questions, context-sensitive on-line help gives immediate assistance. 

Cursors
Cursors let you measure time and amplitude points on the disk waveforms. You can measure the time between gate and signal across two different channels. Different cursor modes are easily recalled and set. They are easily accessed from the front panel or the graphical user interface. Set up basic time or amplitude cursors on a single waveform, or choose to use independent cursors on different waveforms.

Exceptional Trigger Performance
The drive-specific triggers are defined in disk drive terminology, just as they are in the other LeCroy Drive Analyzers. Drive triggers include: Sector, Servo Gate, PES Trigger, and Read Gate Trigger. Setup of trigger conditions is easier then ever. The standard edge trigger will trigger on signals of up to 5 GHz, and on SMART Triggers
®.

ProLink™ Signal Inputs
ProLink inputs provide a high integrity, high bandwidth interchangeable interface to SMA or BNC cables, probes, and accessories. ProLink supports ProBus® for direct, automatic control of LeCroy probes and accessories. The AP-1M adapter (standard) provides High-Z inputs. 

Flexible Connectivity
The DDA 5005A comes complete with a 100Base-T/10Base-T Ethernet connection, a built-in hard drive for waveform storage, and a 3.5" floppy drive. At the press of a button, you can even e-mail the measurement result and scope screen to other engineers or to your notebook. Attach any USB device for extended connectivity for network printing, or for attaching additional storage or pointing devices. An optional built-in graphics printer provides a strip chart display of multiple disk sectors at one viewing.

Specifications

Vertical System 
  
DDA 5005A
  
Analog Bandwidth
@ 50Ω (-3 dB) 
5 GHz 
Input Channels 
Bandwidth Limiter 20 MHz; 200 MHz; 1 GHz; 3 GHz; 4 GHz 
Input Impedance  50 Ω ±1.5%
Input Coupling  DC, GND
Maximum Input  2.5 Vrms; ±4 Vpeak
Vertical Resolution  8 bits; up to 11 bits with
enhanced resolution (ERES) 
Sensitivity  2 mV–1 V/div fully variable;
Full bandwidth at ≥ 10mV
Offset Range  2 mV–99 mV/div: ±750 mV; 100 mV–1 V/div: ±4 V
  
Horizontal System
Timebases  Internal timebase common to 4 input channels; An external clock may be applied at the Auxiliary input
Math & Zoom Traces  8 math/zoom traces
Clock Accuracy  1 ppm @ 0–40 degrees C
Time Interpolator Resolution  1 ps
External Clock Frequency 2 GHz maximum; 50 Ω impedance
Roll Mode - Operating Range  time/div 500 ms - 1000 s/div or sample rate < 100 kS/s max 
  
Acquisition System
Single-Shot Sample Rate/Ch  10 GS/s
2 Channel Max  20 GS/s 
Maximum Acquisition Points/Ch  100 Mpts/ 2 Ch, 50 Mpts/ 4Ch
  
Acquisition Modes
Random Interleaved Sampling (RIS)  200 GS/s for repetitive signals: 
20 ps/div – 1 µs/div
Single-Shot  20 ps/div–10 s/div: For transient and repetitive signals
Sequence  2 – 20,000 segments
Intersegment Time  Typically 5 µs
  
Acquisition Processing 
Averaging  Summed averaging; Continuous averaging
Enhanced Resolution (ERES)  From 8.5 to 11 bits vertical resolution
Envelope (Extrema)  Envelope, floor, roof for up to 1 million sweeps
  
Triggering System 
Modes  Normal, Auto, Single, and Stop
Sources  Any input channel, External, Ext X10, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling Mode  DC
Pre-trigger Delay  0 – 100% of horizontal time scale
Post-trigger Delay  0 – 10,000 divisions
Hold-off by Time or Events  Up to 20s or from 1 to 99 999 999 events
Internal Trigger Range  ±5 div
Max Trigger Frequency  5 GHz with Edge Trigger; 750 MHz with SMART Trigger
External Trigger Input Range  Ext ±0.4; Ext X10 ±0.04; Ext / 10 ±4 V
  
Automatic Setup 
Auto Setup  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals. 
Vertical Find Scale  Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range.
  
Probes 
Probes  A variety of passive and active probes are optional 
Probe System: 
ProLink with Probus
Automatically detects and supports a variety of compatible probes; Supports ProLink SMA or BNC input adapters
Scale Factors  Automatically or manually selected depending on probe used
  
Color Waveform Display
Type  Color 10.4" flat-panel TFT-LCD with high resolution touch panel
Resolution  SVGA; 800 x 600 pixels
Realtime Clock  Dates, hours, minutes, seconds displayed with waveform
Number of Traces  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
Grid Styles  Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY
Waveform Styles  Sample dots joined or dots only
  
Analog Persistence Display
Analog & Color-Graded Persistence  Variable saturation levels; stores each trace’s persistence data in memory
Persistence Selections  Select analog or color positive
Trace Selection  Activate Analog Persistence on all or any combination of traces
Persistence Aging Time  Select from 500 ms to infinity
Sweeps Displayed  All accumulated, or all accumulated with last trace highlighted
  
Zoom Expansion Traces
Display up to 4 Zoom and 4 Math/Zoom traces (8 Math/Zoom traces available with Master Analysis option).
  
Rapid Signal Processing
Processor  Intel Pentium with MS Windows Platform
Processing Memory  512 MBytes
  
Internal Waveform Memory
M1, M2, M3, M4 Internal Waveform Memory (Store full-length waveforms with 16 bits/data point) or store to any number of files limited only by data storage media.
  
Setup Storage
Front Panel and Instrument Status  Store to the internal hard drive, floppy drive, or to a USB connected peripheral device.
  
Interface
Remote Control  Full command set supports front panel controls and internal functions via GPIB or Ethernet.
GPIB Port (Optional)  Full control via IEEE – 488.2
Ethernet Port  10/100BaseT Ethernet interface
Floppy Drive  Internal, DOS-format, 3.5" high-density
USB Ports  Minimum of 2 USB ports support Windows compatible devices
External Monitor Port Standard 15-pin D-Type SVGA-compatible 
Parallel Port  1 standard
  
Auxiliary Output
Signal Types  Select from calibrator or control signals output on front panel
Calibrator Signal 500 Hz – 5 MHz square wave or DC Level
0.0 to +0.5 Volts (selectable) into 50
Ω
Control Signals  Trigger ready, trigger out, pass/fail status 
  
Auxiliary Input
Signal Types  Select from External Trigger or External Clock input on front panel
  
General 
Auto Calibration  Ensures specified DC and timing accuracy is maintained for 1 year minimum
Power Requirements  100–120 V AC at 50/60/400 Hz; 
200–240 V AC at 50/60 Hz; 
Power consumption: < 1 kVA , 940 Watts max
  
Physical Dimensions
Dimensions (HWD)  264 mm x 397 mm x 491 mm; 10.4" x 15.65" x 19.25" (height excludes feet)
Weight  18 kg; 39.5 lbs 
Shipping Weight  24 kg; 53 lbs
  
Warranty and Service
3-year warranty; calibration recommended annually
Optional service programs include extended warranty, upgrades, and calibration services. 
  
Basic Triggers
Edge/Slope/Line Triggers when signal meets slope and level condition.
  
SMART®Triggers 
State or Edge Qualified  Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout  Triggers if signal drops out for longer than selected time between 2 ns and 20 s.
Pattern  Logic combination (AND, NAND, OR, NOR) of 5 inputs 
(4 channels and external trigger input)
Each source can be high, low, or don’t care.
Trigger at start or end of the pattern. 
  
SMART Triggers with Exclusion Technology
Glitch  Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent faults.
Signal or Pattern Width  Triggers on positive or negative pulse widths selectable from 600 ps to 20 s or on intermittent faults.
Signal or Pattern Interval  Triggers on intervals selectable between 2 ns and 20 s.
  
Disk Drive Triggers
Sector Trigger on the n'th sector pulse after index. Index and sector pulse polarity and sector pulse number are selectable.
Servo Gate  Trigger on the n'th servo gate after index and every m'th thereafter. Index and servo gate pulse polarity are selectable.
PES Trigger  Trigger on Position Error Signal (PES) exceeding an adjustable voltage window. Servo gate can be selected as qualifier.
Read Gate Trigger  Trigger on any read gate longer than an adjustable Sector ID filed length.

Math Tools (Standard)
Display up to 8 math function traces (F1 – F8). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace. Function traces can be chained together to perform math-on-math. 

absolute value  log (base 10) 
average (summed) negate
average (continuous) product (x)
difference (–) ratio (/)
differentiate reciprocal (invert) 
enhanced resolution 
(to 11 bits vertical)
resample (deskew)
envelope rescale (with units)
exp (base e)  roof
exp (base 10)  (sin) x/x 
FFT (basic) square 
floor square root 
identity  sum (+)
integrate trend (datalog)
log (base e)  Auto-correlation
Histogram

FFT includes: power averaging, power density, real and imaginary components, and frequency domain parameters. 

Pass/Fail Testing 
Test waveforms by comparing their shape to test templates and simultaneously check multiple parameters versus selectable parameter or mask limits. Pass or fail conditions can initiate actions including document to local or networked files, or email the image of the failure, saving waveforms, or send a GPIB SRQ or pulse to trigger another device.

Automated Disk Drive Measurements 

TAA lbase ltmn msnr
TAA+ lbsep ltmx rsnr
TAA- lmax ltot m_to_r
PW50 lmin ltpt nbph
PW50+ lnum lttp nbpw
PW50- lpp ltut
Resolution ltbe NLTS
Overwrite ltbp ACSN

Standard Automated Measurements 

amplitude peak-to-peak
area period
base risetime
cycles rms
cycle std. deviation std. deviation
cycle mean top
cycle median width
cycle rms last
data median
delay number of points
duty cycle phase
duration time @ minimum (min.)
falltime time @ maximum (max.)
frequency Δ delay
first Δ time @ level
maximum Δ time @ level from trigger
mean Δ time from clock to data + (setup time)
minimum Δ time from clock to data- (Hold time)
+overshoot 18 Histogram Parameters
–overshoot

Jitter measurement for parameters including: period, cycle-cycle, frequency, and edge@lv, with JitterTrack up to 200 edges.

Advance Drive Analysis
Advance Drive Analysis capabilities of the DDA5005A include:

  • Head Filter / Equilizer Emulation

  • Channel Emmulation

  • SAM Histograms

  • Plot of SAM values

  • PES Runout Analysis 

  • Analog Compare

Additional waveshape analysis capabilities include:

  • FFT capability includes: power averaging, power density, real and imaginary components and frequency domain parameters

  • Parameter Math - add, subtract, multiply or divide two different parameters

  • User-definable parameter measurements

  • User-definable math functions 

DDA5005A Ordering Information

Four Channel Disk Drive Analyzer Product Code
5 GH/s, 20 GS/s, 2 Channel; 10GS/s Color DSO
48 Mpts/2 Ch; 24 Mpts/Ch Standard 
DDA 5005A
5 GHz, 20 GS/s 2 Ch; 10 GS/s Ch, Color DSO 
100 Mpts 2 Ch; 50 Mpts/Ch Standard 
DDA 5005A XXL
 
Included with standard configuration  
CD-ROM Drive  
Floppy Disk Drive  
LeCroy ProLink Adapter SMA and BNC  
Optical 3 button Wheel Mouse-USB  
Operator’s Manual, Quick Reference Guide, CD-ROM with OM/RCM, and Utility software  
Protective Front Cover  
Remote Control Manual   
Standard Commercial Calibration and Performance Certificate  
Standard Ports; 10/100BaseT Ethernet, Parallel, SVGA Video Output, USB  
Three-Year Warranty
 
Selected Accessories  Product Code
Hardware Options
LeCroy ProLink Adapter BNC  LPA-BNC 
High Impedance Adapter - Includes PP005A Passive probe AP-1M 
 
WaveShape Analysis Packages
Digital Filter Package DFP2
Jitter and Timing Analysis Package JTA2
Serial Data Mask Testing Package SDM
 
Selected Accessories 
Keyboard KYBD-1
LeCroy Prolink Adapter BNC LPA-BNC
LeCroy Prolink Adapter BNC kit of 5 LPA-BNC-Kit
2.5 GHz Active Voltage Probe  HFP 2500
7.5 GHz Passive Probe  PP066
Differential Probe  AP034
Oscilloscope Cart OC1021
Oscilloscope Cart with additional shelf and drawer OC1024
Rackmount Kit - 25" Slide RMA-25
Rackmount Kit - 30" Slide RMA-30
 
Warranty & Calibration
NIST Traceable Calibration and Certificate DDA-CCNIST
MIL Standard Traceable Calibration and Certificate