DDA5005A
and DDA5005AXXL
Disk
Drive Analyzers
|
Accurately capture and analyze many sectors, or a complete track for read channel design or head/media evaluation.
|
|
Leading
Features
- 5 GHz bandwidth
- 10 GS/s sample rate/channel
- 20 GS/s dual-channel mode
- Up to 100 Mpts in dual-channel mode
- 5 GHz trigger bandwidth
- Intuitive front panel and touch screen interface
- Zoom and Multi-Zoom on disk sectors
- One-button access to Read Channel Emulation, Servo
Analysis, Disk Triggers
- Head Equalization, Channel Emulation and SAM Histograms
- Segmented Memory for sector-by-sector parametric analysis
- Built in PWxx, amplitude, pulseshape and ACSN parametric measurements
- Customizable with MATLAB scripts
- Flexible connectivity to networks, peripherals with 100Base-T Ethernet and USB
Maximum
Performance
The Disk Drive Analyzer 5005A, with 5 GHz bandwidth, includes LeCroy’s newest and most powerful Disk Drive Analysis toolset. Capture, view, and analyze the waveshape of high-speed, complex drive signals with speed and integrity.
LeCroy’s X-Stream architecture integrates SiGe “digitizer on a chip“ technology and a specialized high-speed streaming bus design to transfer data from the ADC to a proprietary acquisition memory. The X-Stream architecture enables disk drive engineers to quickly and easily measure and analyze disk drive signals. With 10 GS/s and 24 Mpts/Ch—up to 20 GS/s and 48 Mpts on two channels—you can be assured drive signals are captured with accuracy and precision.
The DDA 5005A is designed for signal fidelity, whole track acquisition and analysis for read channel, media noise analysis, and head parametrics, with the longest acquisition memory standard. The DDA 5005A comes standard with enough acquisition memory to capture 2.4 milliseconds of data at 20 GS/s, while the XXL model captures 5 milliseconds with its 100 Mpts per dual-channel memory.
Excellence in Head,Disk,Track, and Noise Analysis
The DDA series analyzers incorporate the tools to make you most efficient. The standard 100 Mpts of capture memory in the DDA 5005A XXL provides 5 milliseconds of single-shot, 20 GS/s capture speed on two channels.
Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 5 GHz and then QuickZoom from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple Zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. You can measure the time between two events accurately with horizontal and vertical cursors. Disk drive parameters let you characterize the pulse width variation or signal-to-noise ratio across a selectable region. Failure Analysis Engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good signals. Analog-to-digital converters running at speeds up to 20 GS/second ensure the right oversampling rate to measure today’s high-speed read channels. In every DDA,you can run your MATLAB scripts to view the captured signal, with the filters matched to your channel and media.

WaveLink high bandwidth differential probes let you
capture head signals with best signal to noise ratio.
Triggers Designed for Drive Analysis
Disk Triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with 50 or 100 picosecond/sample time resolution. Up to 20,000 sectors of data can be gathered with a DDA 5005A equipped with the DDA-XXL option.
Natural
Graphical Interface
One press of the DDA button takes you directly to the Disk Drive Analyzer features.The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, reacts quickly to your commands. Functionality is exactly where you expect it to be. If you have questions, context-sensitive on-line help gives immediate assistance.

Cursors
Cursors let you measure time and amplitude points on the disk waveforms. You can measure the time between gate and signal across two different channels. Different cursor modes are easily recalled and set. They are easily accessed from the front panel or the graphical user interface. Set up basic time or amplitude cursors on a single waveform, or choose to use independent cursors on different waveforms.
Exceptional
Trigger Performance
The drive-specific triggers are defined in disk drive terminology, just as they are in the other LeCroy Drive Analyzers. Drive triggers include: Sector, Servo Gate, PES Trigger, and Read Gate Trigger. Setup of trigger conditions is easier then ever. The standard edge trigger will trigger on signals of up to 5 GHz, and on SMART Triggers®.
ProLink™
Signal Inputs
ProLink inputs provide a high integrity, high bandwidth interchangeable interface to SMA or BNC cables, probes, and accessories. ProLink supports ProBus® for direct, automatic control of LeCroy probes and
accessories. The AP-1M adapter (standard) provides High-Z inputs.

Flexible
Connectivity
The DDA 5005A comes complete with a 100Base-T/10Base-T Ethernet connection, a built-in hard drive for waveform storage, and a 3.5" floppy drive. At the press of a button, you can even e-mail the measurement result and scope screen to other engineers or to your notebook. Attach any USB device for extended connectivity for network printing, or for attaching additional storage or pointing devices. An optional built-in graphics printer provides a strip chart display of multiple disk sectors at one viewing.
Specifications
Vertical
System
|
DDA
5005A
|
Analog
Bandwidth
@ 50Ω (-3 dB) |
5
GHz |
| Input
Channels |
4 |
| Bandwidth
Limiter |
20 MHz; 200 MHz; 1 GHz; 3 GHz; 4 GHz |
| Input
Impedance |
50
Ω ±1.5% |
| Input
Coupling |
DC,
GND |
| Maximum
Input |
2.5
Vrms; ±4 Vpeak |
| Vertical
Resolution |
8
bits; up to 11 bits with
enhanced resolution (ERES) |
| Sensitivity |
2 mV–1 V/div fully variable;
Full bandwidth at ≥ 10mV |
| Offset
Range |
2 mV–99 mV/div: ±750 mV; 100 mV–1 V/div: ±4 V |
| Horizontal
System |
| Timebases |
Internal
timebase common to 4 input channels; An external clock
may be applied at the Auxiliary input |
| Math
& Zoom Traces |
8
math/zoom traces |
| Clock
Accuracy |
≤
1
ppm @ 0–40 degrees C |
| Time
Interpolator Resolution |
1
ps |
| External
Clock Frequency |
2
GHz maximum; 50 Ω impedance |
| Roll
Mode - Operating Range |
time/div
500 ms - 1000 s/div or sample rate < 100 kS/s
max |
| Acquisition
System |
| Single-Shot
Sample Rate/Ch |
10
GS/s |
| 2
Channel Max |
20
GS/s |
| Maximum
Acquisition Points/Ch |
100 Mpts/ 2 Ch, 50 Mpts/ 4Ch |
| Acquisition
Modes |
| Random
Interleaved Sampling (RIS) |
200
GS/s for repetitive signals:
20 ps/div – 1 µs/div |
| Single-Shot |
20 ps/div–10 s/div: For transient and repetitive signals |
| Sequence |
2
– 20,000 segments |
| Intersegment
Time |
Typically
5 µs |
| Acquisition
Processing |
| Averaging |
Summed averaging; Continuous averaging |
| Enhanced
Resolution (ERES) |
From 8.5
to 11 bits vertical resolution |
| Envelope
(Extrema) |
Envelope,
floor, roof for up to 1 million sweeps |
| Triggering
System |
| Modes |
Normal,
Auto, Single, and Stop |
| Sources |
Any
input channel, External, Ext X10, Ext/10, or line; slope
and level unique to each source (except line trigger) |
| Coupling
Mode |
DC |
| Pre-trigger
Delay |
0 –
100% of horizontal time scale |
| Post-trigger
Delay |
0 –
10,000 divisions |
| Hold-off
by Time or Events |
Up to
20s or from 1 to 99 999 999 events |
| Internal
Trigger Range |
±5 div |
| Max
Trigger Frequency |
5 GHz
with Edge Trigger; 750 MHz with SMART Trigger |
| External
Trigger Input Range |
Ext
±0.4; Ext X10 ±0.04; Ext / 10 ±4 V |
| Automatic
Setup |
| Auto
Setup |
Automatically
sets timebase, trigger, and sensitivity to display a
wide range of repetitive signals. |
| Vertical
Find Scale |
Automatically
sets the vertical sensitivity and offset for the
selected channels to display a waveform with maximum
dynamic range. |
| Probes |
| Probes |
A
variety of passive and active probes are optional |
Probe
System:
ProLink with Probus |
Automatically
detects and supports a variety of compatible probes;
Supports ProLink SMA or BNC input adapters |
| Scale
Factors |
Automatically
or manually selected depending on probe used |
| Color
Waveform Display |
| Type |
Color
10.4" flat-panel TFT-LCD with high resolution touch
panel |
| Resolution |
SVGA;
800 x 600 pixels |
| Realtime
Clock |
Dates,
hours, minutes, seconds displayed with waveform |
| Number
of Traces |
Display
a maximum of 8 traces. Simultaneously display channel,
zoom, memory, and math traces. |
| Grid
Styles |
Single,
Dual, Quad, Octal, XY, Single + XY, Dual + XY |
| Waveform
Styles |
Sample
dots joined or dots only |
| Analog
Persistence Display |
| Analog
& Color-Graded Persistence |
Variable
saturation levels; stores each trace’s persistence
data in memory |
| Persistence
Selections |
Select
analog or color positive |
| Trace
Selection |
Activate
Analog Persistence on all or any combination of traces |
| Persistence
Aging Time |
Select
from 500 ms to infinity |
| Sweeps
Displayed |
All
accumulated, or all accumulated with last trace
highlighted |
| Zoom
Expansion Traces |
| Display
up to 4 Zoom and 4 Math/Zoom traces (8 Math/Zoom traces
available with Master Analysis option). |
| Rapid
Signal Processing |
| Processor |
Intel
Pentium with MS Windows Platform |
| Processing
Memory |
512
MBytes |
| Internal
Waveform Memory |
| M1,
M2, M3, M4 Internal Waveform Memory (Store full-length
waveforms with 16 bits/data point) or store to any
number of files limited only by data storage media. |
| Setup
Storage |
| Front
Panel and Instrument Status |
Store
to the internal hard drive, floppy drive, or to a USB
connected peripheral device. |
| Interface |
| Remote
Control |
Full
command set supports front panel controls and internal
functions via GPIB or Ethernet. |
| GPIB
Port (Optional) |
Full
control via IEEE – 488.2 |
| Ethernet
Port |
10/100BaseT
Ethernet interface |
| Floppy
Drive |
Internal,
DOS-format, 3.5" high-density |
| USB
Ports |
Minimum
of 2 USB ports support Windows compatible devices |
| External
Monitor Port Standard |
15-pin
D-Type SVGA-compatible |
| Parallel
Port |
1
standard |
| Auxiliary
Output |
| Signal
Types |
Select
from calibrator or control signals output on front panel |
| Calibrator
Signal |
500 Hz
– 5 MHz square wave or DC Level
0.0 to +0.5 Volts (selectable) into 50 Ω |
| Control
Signals |
Trigger
ready, trigger out, pass/fail status |
| Auxiliary
Input |
| Signal
Types |
Select
from External Trigger or External Clock input on front
panel |
| General |
| Auto
Calibration |
Ensures
specified DC and timing accuracy is maintained for 1
year minimum |
| Power
Requirements |
100–120
V AC at 50/60/400 Hz;
200–240 V AC at 50/60 Hz;
Power
consumption: < 1 kVA , 940 Watts max |
| Physical
Dimensions |
| Dimensions
(HWD) |
264 mm x
397 mm x 491 mm; 10.4" x 15.65" x 19.25"
(height excludes feet) |
| Weight |
18 kg;
39.5 lbs |
| Shipping
Weight |
24 kg;
53 lbs |
| Warranty
and Service |
| 3-year
warranty; calibration recommended annually |
| Optional
service programs include extended warranty, upgrades,
and calibration services. |
| Basic
Triggers |
| Edge/Slope/Line |
Triggers
when signal meets slope and level condition. |
| SMART®Triggers |
| State
or Edge Qualified |
Triggers
on any input source only if a defined state or edge
occurred on another input source. Delay between sources
is selectable by time or events. |
| Dropout |
Triggers
if signal drops out for longer than selected time
between 2 ns and 20 s. |
| Pattern |
Logic
combination (AND, NAND, OR, NOR) of 5 inputs
(4 channels
and external trigger input)
Each source can be high, low, or don’t care.
Trigger
at start or end of the pattern. |
| SMART
Triggers with Exclusion Technology |
| Glitch |
Triggers
on positive or negative glitches with widths selectable
from 600 ps to 20 s or on intermittent faults. |
| Signal
or Pattern Width |
Triggers
on positive or negative pulse widths selectable from 600
ps to 20 s or on intermittent faults. |
| Signal
or Pattern Interval |
Triggers
on intervals selectable between 2 ns and 20 s. |
| Disk
Drive Triggers |
| Sector |
Trigger
on the n'th sector pulse after index. Index and sector
pulse polarity and sector pulse number are selectable. |
| Servo
Gate |
Trigger
on the n'th servo gate after index and every m'th
thereafter. Index and servo gate pulse polarity are
selectable. |
| PES
Trigger |
Trigger
on Position Error Signal (PES) exceeding an adjustable
voltage window. Servo gate can be selected as qualifier. |
| Read
Gate Trigger |
Trigger
on any read gate longer than an adjustable Sector ID
filed length. |
Math
Tools (Standard)
Display up to 8 math function traces (F1 – F8). The
easy-to-use graphical interface simplifies setup of up to two
operations on each function trace. Function traces can be
chained together to perform math-on-math.
| absolute
value |
log
(base 10) |
| average
(summed) |
negate |
| average
(continuous) |
product
(x) |
| difference
(–) |
ratio
(/) |
| differentiate |
reciprocal
(invert) |
enhanced
resolution
(to 11 bits vertical) |
resample
(deskew) |
| envelope |
rescale
(with units) |
| exp
(base e) |
roof |
| exp
(base 10) |
(sin)
x/x |
| FFT
(basic) |
square |
| floor |
square
root |
| identity |
sum (+) |
| integrate |
trend (datalog) |
| log
(base e) |
Auto-correlation |
|
Histogram |
FFT
includes: power averaging, power density, real and imaginary
components, and frequency domain parameters.
Pass/Fail
Testing
Test waveforms by comparing their shape to test templates and
simultaneously check multiple parameters versus selectable
parameter or mask limits. Pass or fail conditions can initiate
actions including document to local or networked files, or
email the image of the failure, saving waveforms, or send a
GPIB SRQ or pulse to trigger another device.
Automated
Disk Drive Measurements
| TAA |
lbase |
ltmn |
msnr |
| TAA+ |
lbsep |
ltmx |
rsnr |
| TAA- |
lmax |
ltot |
m_to_r |
| PW50 |
lmin |
ltpt |
nbph |
| PW50+ |
lnum |
lttp |
nbpw |
| PW50- |
lpp |
ltut |
|
| Resolution |
ltbe |
NLTS |
|
| Overwrite |
ltbp |
ACSN |
|
Standard
Automated Measurements
| amplitude |
peak-to-peak |
| area |
period |
| base |
risetime |
| cycles |
rms |
| cycle
std. deviation |
std.
deviation |
| cycle
mean |
top |
| cycle
median |
width |
| cycle
rms |
last |
| data |
median |
| delay |
number
of points |
| duty
cycle |
phase |
| duration |
time
@ minimum (min.) |
| falltime |
time
@ maximum (max.) |
| frequency |
Δ
delay |
| first |
Δ
time @ level |
| maximum |
Δ
time @ level from trigger |
| mean |
Δ
time from clock to data + (setup time) |
| minimum |
Δ
time from clock to data- (Hold time) |
| +overshoot |
18
Histogram Parameters |
| –overshoot |
|
Jitter
measurement for parameters including: period, cycle-cycle,
frequency, and edge@lv, with JitterTrack up to 200 edges.
Advance
Drive Analysis
Advance Drive Analysis capabilities of the DDA5005A include:
Additional
waveshape analysis capabilities include:
-
FFT
capability includes: power averaging, power density, real
and imaginary components and frequency domain parameters
-
Parameter
Math - add, subtract, multiply or divide two different
parameters
-
User-definable
parameter measurements
-
User-definable
math functions
DDA5005A
Ordering Information
| Four Channel Disk Drive Analyzer |
Product
Code
|
5
GH/s, 20 GS/s, 2 Channel; 10GS/s Color DSO
48 Mpts/2 Ch; 24 Mpts/Ch Standard |
DDA
5005A |
5 GHz, 20 GS/s 2 Ch; 10 GS/s Ch, Color DSO
100 Mpts 2 Ch; 50 Mpts/Ch Standard |
DDA
5005A XXL |
| Included
with standard configuration |
|
| CD-ROM
Drive |
|
| Floppy
Disk Drive |
|
| LeCroy
ProLink Adapter SMA and BNC |
|
| Optical
3 button Wheel Mouse-USB |
|
| Operator’s
Manual, Quick Reference Guide, CD-ROM with OM/RCM, and
Utility software |
|
| Protective
Front Cover |
|
| Remote
Control Manual |
|
| Standard
Commercial Calibration and Performance Certificate |
|
| Standard
Ports; 10/100BaseT Ethernet, Parallel, SVGA Video
Output, USB |
|
| Three-Year
Warranty |
|
| Selected
Accessories |
Product
Code
|
| Hardware
Options |
|
| LeCroy
ProLink Adapter BNC |
LPA-BNC |
| High Impedance Adapter
- Includes PP005A Passive probe |
AP-1M |
| |
| WaveShape
Analysis Packages |
|
| Digital Filter Package |
DFP2 |
| Jitter
and Timing Analysis Package |
JTA2 |
| Serial Data Mask Testing Package |
SDM |
| |
| Selected
Accessories |
|
| Keyboard |
KYBD-1 |
| LeCroy
Prolink Adapter BNC |
LPA-BNC |
| LeCroy
Prolink Adapter BNC kit of 5 |
LPA-BNC-Kit |
| 2.5
GHz Active Voltage Probe |
HFP
2500 |
| 7.5
GHz Passive Probe |
PP066 |
| Differential
Probe |
AP034 |
| Oscilloscope
Cart |
OC1021 |
| Oscilloscope
Cart with additional shelf and drawer |
OC1024 |
| Rackmount
Kit - 25" Slide |
RMA-25 |
| Rackmount
Kit - 30" Slide |
RMA-30 |
| |
| Warranty
& Calibration |
|
| NIST
Traceable Calibration and Certificate |
DDA-CCNIST |
| MIL
Standard Traceable Calibration and Certificate |
| |