D13000PS / D11000PS
Differential Probe System
High-Performance
Probing Solution for
SDA 9000, SDA 11000, SDA 13000,
and SDA 18000
The D13000PS extends the full signal
acquisition performance of the SDA 13000
to the probe tips. With 13 GHz system
bandwidth, the probe enables direct
measurement of high-speed serial data
streams up to 6.25 Gb/s. The D11000PS
also provides 11 GHz system bandwidth

D11000PS
Probe System
Choice of Interconnect Styles Without Compromising
Performance
The D13000PS/D11000PS both provide
direct Solder-In interconnect lead assemblies
and SMA interconnect cables. The
D13000PS also includes SMP interconnect
cables. Each interconnect lead comes
with a dedicated probe amplifier module
that has calibration data optimized for
the respective lead. This eliminates the
performance compromise of using a
single calibration for multiple lead types.
The Solder-In lead provides the highest
possible signal integrity with a high loading
impedance. The dual SMA/SMP interconnect
leads provide a true differential 100 Ω
input (50 Ω each input to ground). This is a
convenient alternative to direct cabling
into the oscilloscope inputs, freeing up the
second channel for other signal input, and
eliminating the need to set up waveform
math and match cable delays.
Unsurpassed Waveform Accuracy
When used to acquire input signal for the
SDA Series oscilloscope, the D13000PS/
D11000PS provides unprecedented
waveform fidelity, even with signals at
higher serial data rates. The D13000PS/
D11000PS utilizes third generation
response compensation calibration, the
most advanced in use today, to provide
optimal system response.
Each individual probe is characterized with
this system. Information on the probe’s
frequency and time domain responses are
stored in non-volatile memory within the
probe amplifier module. This information is
uploaded to the higher bandwidth SDAs
when the probe is connected. The probe
calibration data and the SDA oscilloscope’s
calibration data combine to generate
new equalization filters for the composite
system. The resulting compensation
system corrects for frequency response
deviations, as well as group delay
correction and reflection cancellation.
Reproducing accurate serial data eye
patterns requires maintaining precise
magnitude and phase relationships
between the fundamental and the odd
harmonics. The advanced calibration
system used in the D13000PS/D11000PS
assures the best eye pattern fidelity.
Superior Probe Loading Characteristics
Accurate frequency response is not
enough to assure good waveform fidelity.
Excessive probe loading can cause
waveform distortion. The D13000PS/
D11000PS continues the legacy of LeCroy
high-performance probe design, placing
special emphasis on minimizing loading
of the circuit under test.
The Solder-In lead and dedicated probe
amplifier module have a high input resistance
at DC and low frequencies, allowing
the probe to be used in circuits which
cannot drive the low resistance of a pure transmission line probe. The direct
cabled SMA/SMP inputs have 50 Ω
input impedance with low VSWR.
Ease of Use
Attention to fine details during the
D13000PS/D11000PS design process
has resulted in several "ease of use"
features. A common mode measure
feature allows the user to measure the
average common mode component with
a single click in the probe control menu.
AutoColor ID lights an indicator in the probe
body, matching the color of the waveform
trace. When multiple channels are used,
this feature instantly identifies which
waveform corresponds to which probe.
Several connection accessories designed
specifically for the D13000PS/D11000PS
provide convenient and secure mounting
of the probe body and Solder-In tip to the
test circuit. DC blocking adapters extend
the common mode range of the SMA/
SMP cabled input for use with higher
common mode voltages such as Digital
Video Interface (DVI). A finger wrench
allows tightening of SMA connectors on
dense test fixtures.
Compatibility
The D13000PS is designed specifically
for use with the SDA 13000 and
SDA 18000. The D11000PS is designed
specifically for use with the SDA 11000
and SDA 9000. However, both probing
systems contain additional calibration
data for use with all of the lower
bandwidth WaveMaster®, SDA, and
DDA 5005A Series oscilloscopes
and analyzers.

| Technical Specifications |
|
Bandwidth, System, - 3 dB, |
11
GHz (Typical)* |
13 GHz (Typical)* |
| *Measured as a system with SDA 9000, SDA 11000, SDA 13000 or SDA 18000. |
|
Rise Time, System |
< 50 ps (Typical)* |
< 40 ps (Typical)* |
|
*Measured as a system with SDA 9000, SDA 11000, SDA 13000 or SDA 18000. |
|
Rise Time, Probe only |
<
40 ps |
|
Attenuation,
Nominal |
÷3 |
|
LF Attenuation
Accuracy |
2% (20–30° c) |
|
Output Zero |
< 15 mV referred
to input |
|
Noise, System |
5 mV rms
(Typical)* |
|
*Measured as a system with SDA 9000, SDA 11000, SDA 13000 or SDA 18000. |
|
Differential Mode
Range |
±1
V |
|
Common Mode Range |
±4
V, solder in tip
±2 V, SMA cable input† |
|
†Can be extended by using DC Blocking Adapters. |
Input Resistance
at DC,
(Solder-In lead) |
40 k Ω
differential
20 k Ω each side to ground |
Minimum Input
Impedance
(Solder-In lead, to 11 GHz) |
> 175 Ω
(Refer to graph) |
Input Impedance each input,
(SMA cable input) |
50 Ω |
Input VSWR
(Typical, each lead to ground) |
< 1.5:1 DC – 6 GHz
< 2.0:1 6 GHz–11 GHz |
|
CMRR, (Typical) |
> 40 dB DC –
1 GHz
> 30 dB 1 GHz–4 GHz
> 20 dB 4 GHz–11 GHz |
D13000PS/D11000PS Includes:
Probe amplifier modules (2–1 each
for SMA input and Solder-In lead),
Solder-In lead assembly (2), SMA
interconnect lead, SMA input cables
(matched pair), SMP input cables
for D13000PS only (matched pair),
Probe body, SMA DC blocking
adapters (2), ground lead and clip,
SMA finger wrench (2), tip retaining
clip kit for Solder-In lead, probe body
mounting clamp set, FreeHand probe
stand, ESD dissipating wrist strap,
SAC-01 soft accessory case with
insert, small accessory case,
D13000PS/D11000PS Instruction
Manual, certificate of traceable
calibration.
| |
Product
Code |
| D13000PS |
|
|
13 GHz Differential Probe System |
D13000PS |
|
Replacement Solder-In Interconnect Lead |
D13000SI |
|
Replacement SMP Interconnect Cables |
D13000SMP |
|
Replacement SMA Interconnect Cables |
D13000SMA |
|
NIST Traceable Calibration with Test Data |
D13000PS-CCNIST |
|
D11000PS |
|
|
11 GHz Differential Probe System |
D11000PS |
|
Replacement Solder-In Tip Assembly |
D11000SI |
|
SMP Interconnect Leads |
D11000SMP |
|
Replacement SMA Interconnect Cables |
D11000SMA |
|
NIST Traceable Calibration with Test Data |
D11000PS-CCNIST |
|
|