WaveRunner Oscilloscopes
WR6030,
WR6050, WR6051, WR6100, WR6200 DISCONTINUED
SERIES
For
replacements to these oscilloscope series, please click
here
 |
Excellent
Performance, Great Price, Easy to Use |
Leading
Features
-
350
MHz, 500 MHz, 1 GHz and 2 GHz Bandwidths
-
5 GS/s on All Channels (10 GS/s on 2 Ch for 6100 and 6200)
-
1
Mpts on All Channels, Expandable to 12/24 Mpts
-
Compact
and Lightweight
-
Easy
User Interface
-
New
2.5 mm Passive Probe
-
Touch
Screen Interface
-
Vertical
Controls for Each Channel
-
USB
2.0 and 802.3xx LAN Ports
-
Open
Windows 2000
Excellent Performance, Great
Price, Easy to Use
LeCroy’s WaveRunner®
6000 Series is built to be the world’s best everyday bench oscilloscope. It offers the best acquisition
specifications, a user interface that makes it easy to perform the most common
oscilloscope functions, industry-leading long term support and a
"feel" that makes
the oscilloscope a pleasure to drive.
For the first time, LeCroy has combined the type of high performance front amplifier,
ADC, memory and triggering used in more expensive oscilloscopes and designed it
all into a very affordable package. The WaveRunner 6000 Series also introduces
a user interface that makes viewing and measuring signals simple and fast.
With the WaveRunner 6000 Series, all
viewing controls and basic oscilloscope functions are easily at hand using front
panel knobs. You get fast views and can zoom in to see details on the bright touch
panel color screen. Or use the simple and intuitive controls to call up exactly the
measurements you need.
The WaveRunner 6000 Series includes an industry-leading signal
acquisition path, which provides a 5 GS/s ADC on every channel (Model 6050 and above) and
1 Mbyte of standard memory. No need to worry about the undersampling or
aliasing caused by slower ADCs or shorter memories on other oscilloscopes.
The WaveRunner 6000 Series comes standard with the new PP007 500 MHz
passive probe (one per channel). This 2.5 mm high impedance probe offers
excellent characteristics for probing everyday signals. LeCroy also offers a wide range of
optional single-ended and differential active probes, current probes, optical to electrical
(O/E) converters and differential amplifiers.
Lastly, we decided to architect the oscilloscope so that users could add just the
functionality they want. There are options for testing power devices, serial data mask
testing, jitter and timing analysis, and for a wide variety of probes, O/E converters and
other application specific devices.
Altogether, the WaveRunner 6000 Series sets a new industry standard for high performance
at low price in everyday bench oscilloscopes.
WaveRunner
Specifications
|
Vertical
System |
|
WR
6030 |
WR
6050 |
WR
6051 |
WR
6100 |
WR
6200 |
Analog Bandwidth @ 50Ω,
10 mV–1 V/div,
(-3 dB) |
350
MHz |
500
MHz |
500
MHz |
1
GHz |
2
GHz |
| Rise
Time (Typical) |
1
ns |
750
ps |
750
ps |
400
ps |
255
ps |
| Input
Channels |
4 |
4 |
2 |
4 |
4 |
| Bandwidth
Limiters
|
20
MHz; 200 MHz
|
| Input
Impedance |
1MΩ||<20pF
(10 MΩ || 9.5pF using PP007 probe) |
| Input
Coupling |
50Ω:DC,
1MΩ:AC,
DC, GND |
| Maximum
Input Voltage |
50
Ω:5 V
rms, 1MΩ:250 V max (Peak AC: ≤ 5 kHz + DC) |
|
Channel-Channel Isolation |
>
40dB @ <100MHz (>3dB @ full bandwidth) |
| Vertical
Resolution |
8
bits; up to 11 bits with enhanced resolution (ERES) |
| Sensitivity |
50
Ω:2 mV/div—1 V/div fully variable; 1 MΩ: 2 mV—10 V/div fully variable |
| DC
Gain Accuracy |
±1.0
% of Full Scale (typical); ±1.5%
full scale with V/Div ≥ 10 mV (warranted) |
| Offset
Range |
50Ω:±400
mV @2-4.95 mV/div, ± 1 V @ 5-100 mV/div,
±
10 V @ 102mV - 1 V/div
1MΩ:±400
mV @2-4.95 mV/div, ± 1 V @ 5-100 mV/div,
± 10 V
@ 102mV - 1 V/div, ± 100 V @ 1.02-10 V/div |
| Offset
Accuracy |
±(1.5
% + 0.5 % of offset value + 1 mV) |
| Probing
System |
BNC
or ProBus |
| Timebase
System |
| Timebases |
Internal
timebase common to all input channels; an external clock
may be applied at the Auxiliary Input |
| Time/Division
Range |
Real
Time: 200
ps/div - 10 s/div, RIS mode: to 20ps, Roll mode: up to
1000 s/div |
| Clock
Accuracy |
≤
5 ppm @ 25oc
(≤
10ppm @ 5-40oC) |
| Time
Interval Accuracy |
Clock
Accuracy + Jitter Noise Floor |
| Sample
Rate + Delay Time Accuracy |
Equal
to Clock Accuracy |
| Trigger
& Interpolator Jitter |
≤
3 ps
rms |
|
Channel-
Channel Deskew Range |
±
9x time/div setting, 100 ms max, each channel |
| External
Sample Clock |
DC
to 1 GHz; 50Ω or 1MΩ BNC input. Limited to 2 channel operation, (CH2 only in 6051).
Minimum rise time and amplitude requirements apply at low frequencies. |
| Roll Mode |
User selectable.Available at lower time/div settings. |
| Acquisition
System |
|
WR
6030 |
WR
6050 |
WR
6051 |
WR
6100 |
WR
6200 |
| Single-Shot
Sample Rate/Ch |
2.5
GS/s |
5
GS/s |
5
GS/s |
5
GS/s |
5
GS/s |
| Interleaved
Sample Rate (2Ch) |
N/A |
N/A |
N/A |
10
GS/s |
10
GS/s |
| Max.
Random Interleaved Sampling (RIS) Rate |
<<<
200 GS/s >>> |
| Max.
Trigger Rate |
125,000 waveforms/second |
| Sequence
Time Stamp Resolution |
1
ns |
| Minimum
Time Between Sequential Segments |
8 µs |
| Acquisition
Memory |
| |
Max. acquisition points (4 Ch/2 Ch; 2Ch/1 Ch in
6051) |
Segments
(Sequence Mode) |
| Standard |
1M
/ 2M |
500 |
| Option
S |
2M
/ 4M |
500 |
| Option
M |
4M
/ 8M |
1,000 |
|
Option L |
8M
/ 16M |
5,000 |
| Option
VL |
12M
/ 24M |
10,000 |
| Acquisition
Processing |
| Time
Resolution (min. Single-shot) |
200 ps
(5 GS/s) for WR6030, WR6050 and WR6051;
100 ps (10GS/s)
for WR6100 and WR6200 |
| Averaged |
Summed and
Continuous Averaging to 1
million sweeps |
| (ERES) |
From 8.5
to 11 bits vertical resolution |
| Envelope
(Extrema) |
Envelope,
floor or roof for up to 1 million sweeps |
| Interpolation |
Linear
or Sin X/X |
|
|
| Triggering
System |
| Trigger
Modes |
Normal,
Auto, Single, and Stop |
| Sources |
Any
input channel, External, Ext/10, or line; slope and
level unique to each source |
| Trigger
Coupling |
DC |
| Pre-trigger
Delay |
0 –
100% of memory size (adjustable in 1% increments, or 100
ns) |
| Post-trigger
Delay |
10,000 divisions in real time mode, limited at slower
time/div settings in roll mode |
| Hold-off |
2 ns to 20
s or 1 to 1,000,000,000 events |
| Internal
Trigger Level Range |
±4.1 div
from center (typical) |
| Trigger
Sensitivity with edge trigger (CH1-4+external) |
| For
WR6030 |
2
div at <
350 MHz
1 div at
<
250 MHz |
For
WR6050 &
WR 6051 |
2
div at <
500 MHz
1 div at <
350 MHz |
| For
WR6100 |
2
div at <
1 GHz
1 div at <
750 MHz |
| For
WR6200 |
2 div at
<
2 GHz
1 div at <
1.8 GHz
|
|
| Max.Trigger
Sensitivity Frequency with SMART trigger (CH1-4+external) |
| For
WR6030 |
350 MHz Max
@ ≥
10
mV |
For
WR6050 &
WR 6051 |
500
MHz Max
@ ≥
10 mV |
| For
WR6100 |
750
MHz Max
@ ≥
10 mV |
| For
WR6200 |
750
MHz Max
@ ≥
10 mV |
|
| Trigger
Level DC Accuracy |
± 4%
full scale ±
2 mV (typical) |
| External
Trigger Range |
EXT/10 ±
4V; EXT ± 400mV |
|
|
| Basic
Triggers |
| Edge/Slope/Line |
Triggers when signal meets slope
(positive or negative) and level condition. |
|
|
| SMART Triggers |
| State or Edge Qualified |
Triggers on any input source only if a defined state or edge occurred on another input source. Delay
between sources is selectable by time or events. |
| Dropout |
Triggers if signal drops out for longer than selected time between
2 ns and 20 s. |
| Pattern |
Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger
input, 2 channels and external trigger input (6051))
Each source can be high, low, or don’t care. The High and Low level can be selected independently.
Triggers at start or end of the pattern. |
|
|
| SMART Triggers® with Exclusion Technology |
| Glitch &
Pulse Width |
Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent faults.
(subject to bandwidth limit of oscilloscope). |
| Signal or Pattern Interval |
Triggers
on intervals selectable from 2 ns to 20 s. |
| Timeout
(State/Edge Qualified) |
Triggers on
a source if a given state (or transition edge) has
occurred on another source. Delay between sources is
10ns to 20 s, or 1 to 99,999,999 events. |
| Exclusion
Triggering |
Trigger on
intermittent faults by specifying the normal width
period. |
|
|
| Automatic
Setup |
| Auto
Setup |
Automatically
sets timebase, trigger, and sensitivity to display a
wide range of repetitive signals. |
| Vertical
Find Scale |
Automatically
sets the vertical sensitivity and offset for the
selected channels to display a waveform with maximum
dynamic range. |
|
|
| Probes |
| Probes |
One
PP007 per channel standard; Optional passive and active probes
are available. |
| Probe
System; ProBus |
Automatically
detects and supports a variety of compatible probes. |
| Scale
Factors |
Automatically
or manually selected depending on probe used.
|
|
|
| Color
Waveform Display |
| Type |
Color 8.4" flat-panel TFT-LCD with high resolution touch
screen |
| Resolution |
SVGA;
800 x 600 pixels |
| Real
Time
Clock |
Dates,
hours, minutes, seconds displayed with waveform.
Accurate to ±
50 ppm. SNTP
support to synchronize to precision internet clocks. |
| Number
of Traces |
Display
a maximum of 8 traces. Simultaneously display channel,
zoom, memory, and math traces. |
| Grid
Styles |
Auto, Single,
Dual, Quad, Octal, XY, Single + XY, Dual + XY |
| Waveform
Styles |
Sample
dots joined or dots only |
|
|
| Analog
Persistence Display |
| Analog
& Color-Graded Persistence |
Variable
saturation levels; stores each trace’s persistence
data in memory |
| Persistence
Selections |
Select
analog, color or three dimensional |
| Trace
Selection |
Activate
Persistence on all or any combination of traces |
| Persistence
|
Aging
Time Select from 500 ms to infinity |
| Sweeps
Displayed |
All
accumulated, or all accumulated with last trace
highlighted |
|
|
| Zoom
Expansion Traces |
| Display
up to 4 Math/Zoom traces |
|
|
| CPU |
| Processor |
Intel
Celeron 1.7 GHz or better |
| Processing
Memory |
256 MB on Std, S & M option; 512 MB with L and VL option |
| Operating
System |
Microsoft
Windows 2000 Professional |
|
|
| Internal
Waveform Memory |
| M1,
M2, M3, M4 Internal Waveform Memory (Store full-length
waveforms with 16 bits/data point) or store to any
number of files limited only by data storage media. |
|
|
| Setup
Storage |
| Front
Panel and Instrument Status |
Save
to the internal hard drive, over the network, or to a USB
connected peripheral device. |
|
|
| Interface |
| Remote
Control |
Via
Windows automation, or via LeCroy Remote Command Set. |
| GPIB
Port (Optional) |
Supports
IEEE – 488.2 |
| Ethernet
Port |
10/100Base-T
Ethernet interface (RJ-45 connector) |
| USB
Ports |
5 USB
2.0 ports (one on front of instrument) support Windows compatible devices |
| External
Monitor Port Standard |
Standard
15-pin
D-Type SVGA-compatible DV-15; connect a second
monitor to use dual-monitor display mode. |
| Parallel
Port |
Standard DB-25 |
| Serial
Port |
DB-9
RS-232 port (not for remote oscilloscope control) |
|
|
| Auxiliary
Input |
| Signal
Types |
Select
from External Trigger or External Clock input on front
panel |
| Coupling |
50 Ω: DC,1MΩ: AC, DC,GND |
| Maximum Input Voltage |
50 Ω: 5 Vrms, 1MΩ: 250 Vmax (Peak AC: ≤ 10 kHz + DC) |
|
|
| General |
| Auto
Calibration |
Ensures
specified DC and timing accuracy is maintained for 1
year minimum |
| Probe
Calibrator |
Output available on front panel provides a variety of DC and square wave signals for probe compensation adjustment |
| Power
|
100–240
Vrms at 50/60Hz; 115 Vrms (±10%) at 400 Hz Automatic AC Voltage Selection
Installation Category: 300V CAT II;Max. Power Consumption: 400 VA/400 W; 350 VA/350 W for WaveRunner 6051 |
|
|
|
Environmental
|
| Temperature (Operating) |
+5 °C to +40 °C |
| Temperature (Non-Operating) |
–20 °C to +60 °C |
| Humidity (Operating) |
5% to 80% relative humidity (non-condensing) up to
30 °C. Upper limit derates linearly to 45% relative
humidity (non-condensing) at +40 °C. |
| Humidity (Non-Operating) |
5% to 95% relative humidity (non-condensing) as tested per MIL–PRF–28800F. |
| Altitude (Operating) |
3,048 m (10,000 ft)
max at up
to 25°C |
| Altitude (Non-Operating) |
12,190 m
(40,000 ft) |
|
|
| Physical
Dimensions |
| Dimensions
(HWD) |
211 mm x
355 mm x 363 mm (excludes feet) 8.3" x 13.8" x
14.3" |
| Net
Weight |
10
kg (22 lbs), excluding printer |
| Shipping
Weight |
less
than 13.6 kg (30 lbs) |
|
|
| Certifications |
| CE
Approved, UL and cUL listed; conforms to EN 61326-1,
EN61010-1, UL 3111-1, and CSA C222 N0. 1010.1 |
|
|
| Warranty
and Service |
| 3-year
warranty; calibration recommended annually. |
| Optional
service programs include extended warranty, upgrades and
calibration services. |
|
|
Ordering Information
| WaveRunner
4- Channel Digital Oscilloscope |
Product
Code
|
|
|
| 2 GHz, 5 GS/s-1 Mpts/4 ch; 10 GS/s-2Mpts/2ch, 4 ch Color DSO |
WR
6200
DISCONTINUED
|
|
| 1 GHz, 5 GS/s-1Mpts/4 ch; 10 GS/s-2 Mpts/2ch, 4 ch Color DSO |
WR
6100
DISCONTINUED
|
|
| 500 MHz, 5 GS/s-1 Mpts/4ch; 5 GS/s 2 Mpt/2ch, 4 Ch Color DSO |
WR
6050
DISCONTINUED
|
|
| 500 MHz, 5 GS/s-1 Mpts/2ch; 5 GS/s-2 Mpts/1ch, 2 Ch Color DSO
|
WR
6051
DISCONTINUED
|
|
| 350 MHz,
5 GS/s, 1
Mpts/4 ch; 5 GS/s, 2 Mpts/2 ch, 4-Ch Color DSO |
WR
6030
DISCONTINUED
|
|
|
| Included
with Standard Configuration |
10:1
10
MΩ, 500 MHz BW Passive Probes - Qty 4
(2 with
WaveRunner 6051) |
PP007-WR-1 |
|
CD-ROM containing Operator’s
Manual, Remote
Control Manual, Utility software and Recovery Software |
|
| Printed
Getting Started Manual |
|
| Optical
3 button Wheel Mouse-USB |
|
| Standard
Ports; 10/100Base-T Ethernet, USB (5), Parallel, RS-232,
SVGA Video
Output, Audio input/output |
|
| Internal
Hard Drive |
|
| Protective
Front Cover |
|
| Standard
Commercial Calibration and Performance Certificate |
|
| Three-Year
Warranty |
|
| Memory
Options |
|
| 2
Mpts/Ch, 4 Mpts/Ch using 2 Ch (1 Ch for 6051) |
WR6-S |
| 4
Mpts/Ch, 8 Mpts/Ch using 2 Ch (1 Ch for 6051) |
WR6-M |
| 8
Mpts/Ch, 16 Mpts/Ch using 2 Ch (1 Ch for 6051) |
WR6-L |
| 12
Mpts/Ch, 24 Mpts/Ch using 2 Ch (1 Ch for 6051) |
WR6-VL |
| WaveShape
Analysis Packages |
|
| CAN Bus Tigger and Decode Test Package |
CANbus
TD |
| Jitter
and Timing Analysis |
WR6-JTA2 |
| PowerMeasure
Analysis |
WR6-PMA2 |
| Disk
Drive Measurement Package |
WR6-DDM2 |
| Digital
Filter Package |
WR6-DFP2 |
| Serial
Data Mask Package |
WR6-SDM |
Ethernet
Test Package
(WaveRunner 6100 and 6200 Only1) |
WR6-ENET |
USB
2.0 Compliance Software
(WaveRunner 6200 Only2) |
WR6-USB2 |
| Advanced
Math Package |
WR6-XMATH |
| Intermediate
Math Package |
WR6-XWAV |
| Master
Analysis Package (XMATH + XDEV + JTA2) |
WR6-XMAP |
| Value
Analysis Package (XWAV + JTA2) |
WR6-XVAP |
| Developer's
Customization Kit |
WR6-XDEV |
| Norton
Antivirus |
WR6-AV |
1 Package may be used with lower BW oscilloscope models,
however some measurements will not operate with signals at all
data rates.
2 Can
be used with lower BW oscilloscope models, however only USB
1.1 test functions will be available. WaveRunner 6200 required
for USB 2.0 capacity.
| Selected
Accessories |
|
| 500 MHz Passive Probe |
PP007-1 |
| 2.5
GHz Active Voltage Probe |
HFP
2500 |
| 1.5
GHz Active Voltage Probe |
HFP
1500 |
| 1 GHz Active Voltage Probe |
HFP
1000 |
| 1.0
GHz Differential Probe |
AP034 |
| 500 MHz Differential Probe |
AP033 |
| 30A, 50
MHz Current Probe |
AP015 |
| 500A, 2
MHz Current Probe |
CP500 |
| 150A, 10
MHz Current Probe |
CP150 |
| 15A, 50
MHz Current Probe |
CP015 DISCONTINUED |
| 3 GHz Differential Probe
and tips |
D300
with D300AT |
| 100 MHz
Differential Amplifier |
DA1855A |
| Floppy
Drive (External USB) |
WR6-FLPY |
| Rackmount,
6U height |
WR6-RACK |
| Mini
Keyboard |
WR6-KBD |
| Soft
Shell Carrying Case |
WR6-SOFT |
|
Hard Shell Transit Case |
WR6-HARD |
| Accessory
Pouch |
WR6-POUCH |
| GPIB |
WR6-GPIB |
| 256 MB USB Memory Key |
MEM-USB |
| Oscilloscope
Cart - Basic |
OC1021 |
| Oscilloscope
Cart with additional shelf and drawer |
OC1024 |
| Operator's
Manual Printed Hard Copy |
WR6-OM-E |
| 5-Year
NIST Calibration and Warranty |
WR6-T5 |
|
|