Waverunner-2
Oscilloscope
LT354 model
DISCONTINUED

The LT354 model of Waverunner-2 series scopes provides excellent data acquisition characteristics and terrific value.
document in PDF
format
Leading Features
-
4 Channels
-
500 MHz Bandwidth
-
1 GS/s Single-Shot Sampling Rate on all channels
-
50 GS/s Repetitive Sample Rate
-
Better than 10 ppm Timebase Accuracy with 5 ps resolution
-
Up to 2 Mpt waveforms on all channels (with option ML)
-
8.4 TFT LCD Color Display
-
SMART Triggers include Slew Rate and Runt to
<= 2.5ns (optional)
-
Analog Persistence feature with History view
-
QuickZoom button automatically magnifies
signal views
-
Wavepilot provides quick access to analysis views of measurements such as: FFTs, Histograms, and TrackViews
-
Averaging
and Enhanced Resolution up to 11 bits
-
Deskew and Rescale
-
GPIB, RS-232-C, VGA and Centronics Ports (Standard); Ethernet (Optional)
-
Automatic Pass/Fail Testing
-
PC Card support for hard drives and memory cards
-
Internal Graphics Printer option
The
LT354 is the newest member of the
Waverunner-2
Series of digital oscilloscopes from LeCroy. It provides the power you need to quickly view, measure, and evaluate your signals accurately and reliably all at a reasonable price. The Waverunner-2 series is designed to save engineers valuable time in troubleshooting signals and problem solving.
The Waverunner LT354 provides 500 MHz of bandwidth at 1 GS/s into 2 Mpts of acquisition memory per channel (with the the ML memory option). This allows single-shot capture of long, complex signals at high sampling rates on all 4 channels with no interleaving required. The external trigger input is useful to trigger on an additional signal. Altogether, the Waverunner-2 series provides the bandwidth, sample rate, acquisition memory, and processing power needed to test signals with excellent fidelity, resolution, and precision.
Each Waverunner-2 oscilloscope is an integrated and powerful system providing the capability to CAPTURE, VIEW, and ANALYZE (simple as well as complex) signals. The Wavepilot toolbar offers easy access to popular measurement and analysis functions.
The Wavepilot button provides easy access to analysis capabilities which improve your productivity. You get one-touch operation of features that automatically sets up cursors, creates context-sensitive displays of up to 26 waveform parameters, histograms, and trends. Functions like JitterTrack and TrackView help you track down timing and signal integrity problems right to the source.
Select the best configuration for your needs and budget. If you want to expand in the future, LeCroy provides reasonably priced upgrades for both hardware and software.
Signal Viewing
Display
The bright, clear 8.4" TFT LCD color display makes it easy to see text and signals. Select Full Screen, and the entire display is devoted to signal viewing to enhance signal details. QuickZoom automatically displays up to eight traces on multiple grids with maximum S/N ratio. With a press of the green Analog Persist button, choose the intensity-graded or color-graded view and quickly visualize the signals history.
Analog Persistence with History
The newest function available in Analog Persistence mode is History. You can select History to store and view up to 4,000 sequential acquisitions with individual display of
each event and trigger time down to 1 ns resolution. Scan forward and backward to search for signal errors, then analyze when and why the error occurred.
Quick Zoom
Press QuickZoom to explore signal relationships and inspect or magnify selected regions of a waveform. Use AutoScroll to scan and view details on signals of up to 2 Mpts.
Signal Analysis
Wavepilot
Wavepilot is the easy-to-access signal analysis feature on new Waverunner-2 oscilloscopes. Wavepilot gives you the most direct way to view measurement cursors, or a group of 26 signal parameters or evaluate the signal with graphs including Histograms, TrackView, or the frequency spectrum (FFT) view.
Graph
Press Wavepilot and select Graph for quick and simple setup of measurements, FFT or TrackView trends. Select optional histograms or JitterTrack for accurate and precise results when evaluating critical timing parameters, crosstalk, and signal integrity problems in high-speed designs. All JitterTrack views are synchronized to the signal so you can track problems to the source.
Cursors and Automatic Measurements
Press Wavepilot and select Parameters to view up to 26 of the 28 standard waveform parameters (over 40 are available with optional analysis packages). Its context-sensitive, so if you select FFT, histogram or TrackView, it shows the right parameters with the right units. Select the Cursors button for instant access to cursor measurements.
Signal Analysis Solutions
Optional software packages customize the Waverunner-2 scopes with powerful signal analysis solutions including power measurements, disk drive and media development, wireless and network communications, and computer design. Press Wavepilot and select Analysis Packages for direct access.
Custom DSO
Get your work done fast by automating your analysis with your own customized setups and applications. CustomDSO applications can be created offline and stored on a floppy disk, or on the optional hard drive and memory cards for quick access.
LT354 Waverunner-2 Oscilloscope Configurations
|
LT354 |
| Bandwidth |
500 MHz |
| Input Channels |
4 |
| Maximum Single-Shot Sample Rate/Ch |
1 GS/s |
| Random Interleaved Sampling (RIS) |
50 GS/s for repetitive signals: |
| |
|
| Maximum Acquisition Points |
|
| Standard |
250 k /Ch |
| M memory option |
1 M /Ch |
| ML memory option |
2 M/Ch |
Specifications
| Vertical System |
|
| Input Channels |
4 |
| Analog Bandwidth @ 50
Ohms (-3 dB) |
500 MHz |
| Hardware Bandwidth Limits |
20 MHz or 200 MHz |
| Input Impedance |
50
Ohms ± 1%; 10 MOhms //12 pF typical (using PP006 probe) |
| Input Coupling 1 MOhms: |
AC, DC, GND; 50
Ohms: DC, GND |
| Maximum Input 50
Ohms: |
5 Vrms; 1 MOhms: 400 Vmax (peak AC
<= 5 kHz + DC) |
| Vertical Resolution |
8
bits; up to 11 bits with enhanced resolution (ERES) |
| Sensitivity |
(50
Ohms or 1 MOhms) 2 mV 10 V/div fully variable |
| DC Gain Accuracy |
± (1.5% + 0.5% of full scale) |
| Offset Accuracy |
(50
Ohms or 1 MOhms) ± (1.5% + 0.5% of full scale + 1 mV) |
| Offset Range |
2 mV 99 mV/div: ±1 V
100 mV 99 V/div: ±10 V
1 V 10 V/div: ±100 V |
| Isolation Channel to Channel |
>250:1 at same V/div settings |
|
| Timebase System |
|
| Timebases |
Main and up to four independent zoom traces simultaneously |
| Ranges |
500 ps/div 1000 s/div |
| Clock Accuracy |
<=10 ppm |
| Interpolator Resolution |
5 ps |
| External Clock Frequency
|
500 MHz maximum, 50
Ohms, or 1 MOhms impedance
|
|
Roll Mode Operating Range
|
time/div 500 ms 1000 s/div or sample rate <100
kS/s max
|
|
External Timebase Clock
|
500 MHz maximum external sample clock input on front panel EXT BNC
|
|
|
Acquisition System
|
|
|
Maximum Single Shot Sample Rate/Ch
|
1 GS/s
|
|
Maximum Acquisition Points
|
|
|
Standard
|
250k
|
|
M-option
|
1M
|
|
ML-option
|
2M
|
|
|
Acquisition Modes
|
|
|
Random Interleaved Sampling (RIS)
|
50 GS/s for repetitive signals: 500 ps/div 2 µs/div
|
|
Single Shot
|
For transient and repetitive signals: 500ps/div 100s/div
|
|
Sequence
|
|
|
Standard
|
2 1,000 segments
|
|
Memory Option M or ML
|
2 - 4,000 segments
|
|
Intersegment Time
|
50 µsec max.
|
|
|
Acquisition Processing
|
|
|
Averaging
|
Summed averaging to 10ł
sweeps; continuous averaging with weighting range from 1:1 to 1:1023 (standard).
|
| Enhanced
Resolution (ERES)
|
From
8.5 to 11 bits vertical resolution
|
|
Envelope (Extrema)
|
Envelope, floor, roof for up to 106
sweep
|
|
|
Triggering System
|
|
|
Modes
|
Normal, Auto, Single, and Stop
|
|
Sources
|
Any input channel, external, Ext/10 or line; slope, level, and coupling unique to each source (except line trigger) Inactive channels usable as trigger inputs.
|
|
Slope
|
Positive, Negative, Window
|
|
Coupling modes
|
DC, AC, HF, HFREJ, LFREJ
|
|
AC Cutoff Frequency
|
7.5 Hz Typical
|
|
HFREJ, LFREJ
|
50 kHz typical
|
|
Pre-trigger delay
|
0 100% of horizontal time scale
|
|
Post-trigger delay
|
0 10 000 divisions
|
|
Hold-off by time or events
|
Up to 20s or from 1 to 99 999 999 events
|
|
Internal trigger range
|
±5 div
|
|
Max trigger frequency
|
500 MHz ( with HF trigger coupling)
|
|
External trigger input range
|
±0.5 ( ±5 V with Ext/10 selected )
|
|
Maximum ext. input @ 50 Ohms
|
±5 V DC or 5Vrms
|
|
Maximum ext. input @ 1 MOhms
|
400 Vmax ( DC + peak AC < 5 kHz )
|
|
|
Automatic Setup
|
|
|
Auto Setup
|
Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
|
|
Vertical Find
|
Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range
|
|
|
Probes
|
|
|
Model PP006
|
10:1, 10 MOhms with auto-detect (one per channel)
|
Probe System: ProBus
|
Automatically detects and supports a wide variety of differential amplifiers; active, high-voltage, current, and differential probes
|
|
Scale Factors
|
Up to 12 automatically or manually selected
|
|
|
Color Waveform Display
|
|
|
Type
|
VGA color 8.4" flat-panel TFT-LCD
|
|
Resolution
|
VGA 640 x 480 pixels
|
|
Screen Saver
|
Display blanks after 10 minutes (when screen saver is on)
|
|
Real Time Clock
|
Date, hours, minutes, and seconds displayed with waveform
|
|
Number of Traces
|
Display a maximum of eight traces. Simultaneously display channel, zoom, memory, and math traces
|
| Grid
Styles
|
Single,
Dual, Quad, Octal, XY, Single + XY, Dual + XY;
Full Screen gives enlarged view of each style
|
| Intensity
Controls
|
Separate
intensity control for grids and waveforms
|
|
Waveform Styles
|
Sample dots joined or dots only regular or bold sample point highlighting
|
|
Trace Overlap Display
|
Select opaque or transparent mode with automatic waveform overlap management
|
|
|
Analog Persistence Display
|
|
|
Analog & Color-Graded Persistence
|
Variable saturation levels; stores each traces persistence data in memory
|
|
Trace Selection
|
Activate Analog Persistence on a selected trace, top 2 traces, or all traces
|
|
Persistence Aging Time
|
Select from 500 ms to infinite
|
|
Trace Display
|
Opaque or transparent overlap
|
|
Sweeps Displayed
|
All accumulated or all accumulated with last trace highlighted
|
|
|
Zoom Expansion Traces
|
|
|
Display up to Four Zoom Traces
|
|
|
Vertical zoom
|
Up to 5X expansion, 50X with averaging
|
|
Horizontal zoom
|
Expand to 2 pts/div, magnify to 50,000X
|
|
Auto Scroll
|
Automatically scan and display any zoom or math trace
|
|
|
Rapid Signal Processing
|
|
|
Processor
|
PowerPC
|
|
Processing Memory
|
Up to 128 Mbytes
|
|
Realtime Clock
|
Dates, hours, minutes, seconds, and time stamp trigger time to 1 ns resolution
|
|
|
Internal Waveform Memory
|
|
|
Waveform
|
M1, M2, M3, M4 (Store full-length waveforms with 16 bits/data point)
|
|
Zoom and Math
|
Four traces A, B, C, D with chained trace capability
|
|
|
Setup Storage
|
|
|
Front Panel and Instrument Status
|
Four non-volatile memories and floppy drive are standard. Hard drive and memory card are optional.
|
|
|
Interface
|
|
|
Remote Control
|
Full control of all front panel controls and internal functions via RS232C, GPIB, or Ethernet (optional)
|
|
RS-232-C
|
Asynchronous transfer rate of up to 115.2 kbaud
|
|
GPIB Port
|
Full control via IEEE 488.2; configurable as talker/listener for computer control and data transfer
|
|
Ethernet (optional)
|
10 Base-T Ethernet interface
|
|
Floppy Drive
|
Internal, DOS-format, 3.5" high-density
|
|
PC Card Slot (optional)
|
Supports memory and hard drive cards
|
|
External Monitor Port Standard
|
15-pin
D-Type VGA-compatible
|
|
Centronics Port |
Parallel printer interface |
| Internal
Graphics Printer (optional)
|
Provides
hard copy output in <10 seconds
|
|
|
Outputs
|
|
|
Calibrator Signal
|
500 Hz 1 MHz square wave or DC level; Select from -1.0 to +1.0 into 1 M
Ohms, output on front panel test point and ground lug.
|
|
Control Signals
|
Rear Panel, TTL level, BNC output; Choice of trigger ready, trigger out, pass/fail status. (output resistance
300Ohms ± 10%)
|
|
|
Environmental and Safety
|
|
|
Operating Conditions
|
|
|
Temperature
|
5 40 °C rated accuracy
|
|
0 50 °C operating (electronics)
|
|
-20 60 °C non-operating
|
|
5 50 °C 3.5 floppy drive (operating)
|
|
5 40 °C internal printer (operating)
|
|
Humidity
|
80% max RH, non-condensing up to 35 °C; Derates to 50% max RH, non-condensing at 45 °C
|
|
Altitude
|
4 500 m ( 15 000 ft ) max. up to 25 ŢC; Derates to 2 000 m ( 6 600 ft ) at 45 °C
|
|
CE Approved
|
|
|
EMC
|
EMC Directive 89/336/EEC; EN 61326-1 Emissions and Immunity
|
|
Safety |
Low Voltage Directive
73/23/EEC; EN 61010-1 Product Safety (Installation Category II, Pollution Degree 2) |
|
|
|
UL and cUL approved
|
UL Standard UL 3111-1
|
|
cUL Standard CSA C22.2 No. 1010-1
|
|
|
General
|
|
|
Auto Calibration
|
Ensures specified DC and timing accuracy is maintained for 1 year minimum
|
|
Auto Calibration time
|
< 500 ms
|
|
Power Requirements
|
90 132 VAC at 45 - 440 Hz
|
|
180 - 250 VAC at 45 - 66 Hz
|
|
Automatic AC voltage selection
|
|
Power Consumption: 160 VA max; 210 VA max with internal printer
|
|
Battery Backup
|
Front panel settings retained for two years minimum
|
Warranty and Calibration
|
Three years; calibration recommended yearly
|
|
|
Physical Dimensions
|
|
|
Dimensions (HWD)
|
210 mm x 350 mm x 300 mm; 8.3" x 13.8" x 11.8" (height excludes feet)
|
|
Weight
|
19 lbs (8.5 kg)
|
|
Shipping Weight
|
31 lbs (14 kg)
|
|
|
Math Tools
|
|
|
Simultaneously perform up to four math (signal) processing functions; traces can be chained together to perform math on math.
|
|
|
Standard Math Tools
|
|
| average (sum to 4 000 sweeps) |
product |
| average (continuous weighted) |
ratio |
difference enhanced resolution
(to 11 bits) |
reciprocal (invert) |
| envelope |
resample
(deskew) |
| FFT of 50 kpoint waveforms |
rescale (with units) |
| floor |
roof |
| identity |
sine x/x |
| negate |
sum |
|
|
Measure Tools
|
|
|
|
Automated Measurements: Display any five parameters together with their average, high, low, and standard deviations.
|
|
|
Standard Measure Tools
|
|
|
| amplitude
|
fall 90-10% |
period |
| area |
fall 80-20% |
phase |
| base |
frequency |
rise 10-90% |
| cycle mean |
maximum |
rise 20-80% |
| cycle rms |
mean |
rms |
| cycles |
minimum |
sdev |
| delay |
+overshoot |
top |
delay |
overshoot |
width |
| duty cycle |
peak-to-peak |
xamn |
|
|
|
xamx |
|
|
|
Pass/Fail
|
|
|
Test any five parameters against selectable thresholds. Limit testing is performed using masks created on the scope or PC. Set up a pass or fail condition to initiate actions such as hard copy output, saving waveform to memory, GPIB SRQ, or
pulse out.
|
|
|
Cursor Measurements
|
|
Type
|
Symbol
|
From
|
To
|
|
Relative time
|
 |
First point on
waveform
|
Any other point on waveform |
|
Relative voltage
|
 |
Select voltage level
|
Any other voltage level
| |