SDA 7 Zi Serial Data Analyzers
SDA 7 Zi Serial Data Analyzers are based on the WavePro 7 Zi Series oscilloscope and are equipped with double the standard memory to capture more unit intervals in the eye diagram. They include an enhanced high-speed serial pattern trigger that operates on up to 80 bit patterns and at speeds up to 2.7 Gb/s. Whether debugging eye pattern failures, or other compliance test failures, the SDA Series has easily accessible tools that rapidly isolate the source of the problem in your design.
Explore SDA 7 Zi
|
SDA 725Zi (2.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate) SDA 735Zi (3.5 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate) SDA 740Zi (4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate) SDA 760Zi (6 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Max Sample Rate)
Powerful SDA II Analysis Package Unleash the power of serial data analysis to understand and characterize your design, prove compliance, and determine why a device or host fails compliance. But how do you determine why a device fails compliance? LeCroy's SDA II serial data debug software is the most powerful and versatile solution for finding the root cause of serial data compliance failures. SDA II provides the confidence you need to ensure proper functionality. While some solutions simply provide problem notifications, the SDA 7 Zi is the only oscilloscope that helps you identify the problem and and put your project back on schedule. Versatile SDA II for Compliance and Debug For compliance testing, LeCroy's QualiPHY compliance test suite provides the best available solutions to automate, configure and document standardized tests. However, when a design fails a compliance test, the engineer needs an advanced set of tools to identify and solve those problems. The LeCroy SDA 7 Zi includes a debugging toolset that provides insight into eye and jitter analysis. Armed with this insight, engineers can confidently drill down and identify the root cause. The Quick View of the SDA shows the Eye Diagram, TIE Track, Bathtub Curve, Jitter histogram, NQ-Scale and Jitter Spectrum. No other analyzer provides simultaneous interaction and real-time changes in all six measurements. LeCroy's X-Stream II Architecture provides fast updates and the fastest eye interpretation. The fastest eye building and the maximum unit intervals per second means the shortest time to reach a solution. A high-speed serial trigger enables triggering on up to 2.7 GB/s serial patterns of up to 80-bits in length, allowing up to two 8b/10b primitives to be triggered on. Jitter calculations are based on statistics. With the most advanced long memory performance to 256 Mpts/Ch and X-Stream II enabled responsiveness, eye and jitter analysis occurs rapidly. Automated Compliance Testing QualiPHY compliance test suite provides easy to use step-by-step instructions for testing compliance on a wide array of serial data standards. Fast automated test operation, illustrated instructions, and connection diagrams simplify the process. Complete test reporting is provided along with a 'stop on fail' feature which begins the debug process. Whether debugging eye pattern or other compliance test failures, the SDA 7 Zi Series has the accessible tools. Rapidly isolate the source of the problem in your design. Advanced usability like 8b/10b decode, mask violation locator, ISI plot, and equalization are easy to find. Provide cable characteristics and Cable De-embedding automatically adjusts for the cable effects. The result—true rise time and amplitudes in measurements. The SDA uses the same flexible math on math analysis which is valuable when understanding design behavior in the event of a compliance failure. 
SDA II – Advanced Tools to Isolate and Analyze Flow Diagram User Interface Eye and Jitter Analysis in the SDA 7 Zi begins with a simple, interactive flow diagram user interface intuitively guiding the user through the setup of Eye Measurements, Jitter Measurements, or both at the same time. Serial Trigger The SDA 7 Zi Series comes standard with the 80-bit Pattern Trigger installed. The SDA 760Zi and SDA 740Zi include the High-speed Pattern Trigger option (up to 2.7 Gb/s), while the SDA 735Zi and SDA 725Zi pattern triggers up to 1.25 Gb/s. Both pattern triggers provide a recovered clock and data output on the front of the oscilloscope. 8b/10b Decoding LeCroy's 8b/10b serial decode option with powerful search capability enables captured waveforms to be searched for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes. Equalization Equalization removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization. ISI Plot The ISI plot displays data dependent jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data dependent jitter without the need for a repeating bit pattern. Jitter Spectrum - The jitter spectrum plot allows viewing of any periodic jitter
- Peak annotation displays the frequencies directly on the spectrum
- The LeCroy spectrum plot allows viewing of DDj removal for maximum understanding
Jitter Trend - Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
- The jitter trend clearly shows any non-stationary jitter behavior
Histogram & Bathtub - Display of measured jitter histogram clearly shows any unusual jitter distributions such as bi-modal or non-Gaussian tails. By simply viewing the jitter breakdown (Rj, Dj), the raw data view shows jitter behavior that can be lost
- This unprocessed display gives a high degree of confidence in the accuracy of the jitter breakdown and bathtub curve
Eye Patterns Show Mask Violations to the Bit - Eye pattern measurement on up to 8 million consecutive bits ensures that even transient jitter and noise events are captured
- Consecutive bit eye pattern analysis allows for the measurement of the wave shapes of individual bits that violate the compliance mask (violation location)
- The fastest UI accumulation and very low measurement jitter (typically 1 ps rms)
Cable De-embedding Even expensive, high-performance cabling can have an adverse effect on measurements and steal margin from a design. Cable losses and slow rise times can lead to intersymbol interference that is induced by the measurement system but is not present in the design. The cable de-embedding feature removes these adverse effects leading to more accurate measurements. Superior Eye Diagram Analysis SDA II Advanced Debug for Eye and Jitter Analysis LeCroy''s X-Stream II technology enables unprecedented speed in eye diagram creation. With a 15.3" high definition display and flexible landscape views, the SDA 7 Zi provides more insight into eyes than ever before. New features, such as IsoBER, add insight to the traditionally non-quantitative view of eye openings. In addition, properly distinguishing between the random and deterministic jitter in a serial data signal is a crucial part of being able to reduce the overall jitter. For example, properly identifying frequencies at which periodic jitter is present is typically a common part of determining that jitter source. The SDA 7 Zi is the only analyzer that fully integrates jitter measurements into the oscilloscope software leading to greater confidence in jitter measurements. Dual-Eye View Mode Viewing the Transition and Non-Transition eye diagrams allows for analysis of de-emphasis in serial data waveforms. In addition, Dual-Eye Gated enables the creation of two separate eyes based on a separate signal input (i.e. Read/Write). Mask Violation Locator Mask failures are identified by contrasting color spots which appear anywhere the data intersects the mask template. Users can call up the actual stored bit stream waveform at the point in time of the initial failure. The actual bit sequence is also identified, pointing out any ISI problems. Instantly jump to the next violation, or any other within the stored pattern. IsoBER Mask testing is not always the best way to determine if the signal is going to meet Bit Error Rate requirements because it lacks quantitative analysis of vertical noise and jitter. LeCroy's unique IsoBER analysis tool provides this quantitative analysis by extrapolating the eye diagram data and displaying the lines of BER directly on the eye. This helps to quickly determine the minimum eye opening and also is instrumental in detecting cross-talk by analyzing the vertical eye closure. These measurements are not possible with standard eye diagram techniques. More confidence in jitter Breakdown Simplify Jitter Decomposition The sources of jitter can be categorized as Deterministic or Random, which is an important distinction in calculating the Total Jitter (TJ) of a signal. There are cases where cross talk, or other types of deterministic jitter, can masquerade as random jitter and cause incorrect calculations. LeCroy's integrated SDA II jitter analysis offers two decomposition algorithms to account for these situations, giving the user confidence that all jitter components are accurately recognized and processed correctly. The jitter decomposition calculates both methods simultaneously and alerts the user only when there is a deviation between the results, giving assurance that the correct jitter values are displayed. Intuitive Jitter Breakdown Displays LeCroy's SDA II Serial Data Analysis provides intuitive graphical views of jitter decomposition to quicken insight to the root cause. To understand deterministic jitter values and their sources, SDA II provides the following tools: - Periodic Jitter Spectrum identifies the sources contributing the highest values of Pj.
- ISI Plot isolates bit patterns that contribute the most Intersymbol Interference (ISI)
- DDJ Histogram provides a greater understanding of the distributionof Data Dependent Jitter (DDJ)
Setup Warning Indicators Green / Yellow / Red setup warning indicators alert the user if there is something that requires their attention. For example, if the user's input signal is a clock and they have not selected clock as their signal type, a yellow indicator will be displayed informing the user that they have an inconsistency in the setup that may require their attention.
Main Specifications | | Bandwidth | 2.5 - 6 GHz | | Starting from | $40,675 | | Standard Memory | 20 Mpts/ch | | Max Memory | 256 Mpts/ch | | Max Sampling Rate | 40 GS/s | | |
Memory Options | SDAZi-S-32 32 Mpt/Ch (64 Mpt/Ch Interleaved) Memory Option for SDA Zi. Includes an additional 2 GB of RAM (4 GB total) | SDAZi-M-64 64 Mpt/Ch (128 Mpt/Ch Interleaved) Memory Option for SDA Zi. Includes an additional 4 GB of RAM (8 GB total) | SDAZi-L-128 128 Mpt/Ch (256 Mpt/Ch Interleaved) Memory Option for SDA Zi | Computer Upgrade | WPZi-4-UPG-8GBRAM Upgrade from 4 GB to 8 GB CPU RAM | GPIB-2 GPIB Option for LeCroy oscilloscope. Half-height card with custom connector. | WPZi-500GB-HD Upgrade from standard size hard drive to 500 GB hard drive | WPZi-160GB-RHD-02 Additional 160 GB Hard Drive for WPZi. Includes Windows Vista OS, LeCroy oscilloscope software and critical scope operational file duplicates. | WPZi-500GB-RHD-02 Additional 500 GB Hard Drive for WPZi. Includes Windows Vista OS, LeCroy oscilloscope software and critical scope operational file duplicates. | Serial Data Analysis | WPZi-EYEDRII Eye Doctor II Advanced Signal Integrity Tools for WavePro 7 Zi Oscilloscopes, SDA 7 Zi Serial Data Analyzers, and DDA 7 Zi Disk Drive Analyzers | Serial Data Compliance | QPHY-DDR2 QualiPHY DDR2 Compliance Software Option | QPHY-DDR3 QualiPHY Enabled DDR3 Software Option | QPHY-ENET QualiPHY Ethernet Application Software | QPHY-HDMI QualiPHY Enabled HDMI Software Option (TF-HDMI-3.3V-QUADPAK required;WavePro 760Zi requires SDA II option) | QPHY-PCIe QualiPHY Enabled PCIe Software Option (for Gen1 and Gen2 testing) | QPHY-SATA QualiPHY Enabled SATA Software Option | QPHY-USB USB Application Software Package | QPHY-UWB WiMedia UWB Transmitter Measurement Software Option | ENET-2ADA-BNCSMA 2 x BNC to SMA Adapter | ENET-2CAB-SMA018 2 x 18 inch SMA to SMA Cable | ENET-2CAB-SMA036 2 x 36 inch SMA to SMA Cable | TF-DSQ Probe Deskew and Calibration Fixture | TF-ENET-B 10/100/1000Base-T Compliance Test Fixture | TF-ET Telecom Adaptor Kit 100Ω, 120Ω, 75Ω | TF-HDMI-3.3V-QUADPAK HDMI Pull-Up Terminator Quad Pack – for Use with the Efficere ET-HDMI-TPS-S Test Fixture | TF-SATA-C SATA Compliance Test Fixture (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required) | TF-SATA-C-Kit SATA Compliance Test Kit (*WavePro 7 Zi and WaveMaster 8 Zi class oscilloscopes require the SDA II software option; **20M memory required) | TF-USB-B USB 2.0 Testing Compliance Test Fixture | Serial Trigger and Decode | WPZi-I2Cbus TD I2C Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-SPIbus TD SPI Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-UART-RS232bus TD UART and RS232 Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-CANbus TD CAN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-CANbus TDM CAN Bus Trigger, Decode, and Measure Option for WavePro Zi Series Oscilloscopes | WPZi-FlexrayBus TD FlexRay Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-FlexRayBus TDP FlexRay Bus Trigger, Decode, and Physical Layer Test Option for WavePro Zi Series Oscilloscopes | WPZi-LINbus TD LIN Bus Trigger & Decode Option for WavePro Zi Series Oscilloscopes | WPZi-AudioBus TD AudioBus Trigger and decode Option for WavePro 7Zi | WPZi-AudioBus TDG AudioBus Trigger, decode, and Graph Option for WavePro 7Zi | WPZi-ProtoSync PE Oscilloscope & PCIe Protocol Analyzer Synchronization Option | WPZi-ProtoSync PE-B Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option | WPZi-ProtoSync PE-B-ExtDisp Oscilloscope & PCIe Protocol Analyzer+Bit Tracer Synchronization Option with Zi-EXTDISP-15 Display | WPZi-1553 TD MIL-STD-1553 Trigger and decode option for WavePro Zi | High Speed Output Accessories | LSIB-1 High speed PCIe Gen1 x4 digitizer output for LeCroy oscilloscope. Half-height card with custom connector | LSIB-HOSTBOARD PCI Express x4 Host Interface Board for desktop PC | LSIB-HOSTCARD PCI Express x1 Express Card Host Interface for laptop Express Card slot | LSIB-CABLE-3M PCI Express x 4 3-meter cable with x4 cable connectors included | LSIB-CABLE-7M PCI Express x 4 7-meter cable with x4 cable connectors include | Mixed Signal Solutions | MS-500 500 MHz Maximum Input Frequency, 18 Channels, 50 Mpts/ch Mixed Signal Oscilloscope Option | MS-500-36 250 MHz Maximum Input Frequency, 36 Channels, 25 Mpts/ch Mixed Signal Oscilloscope Option | MS-250 250 MHz Maximum Input Frequency, 18 Channels, 10 Mpts/ch Mixed Signal Oscilloscope Option | Mixed Signal Accessories | PK400-1 Large gripper probe set for 0.10'' (2.54 mm) pin pitch, includes 10 probes with color-coded leads | PK400-2 Medium gripper probe set for 0.04'' (1.0 mm) pin pitch, includes 10 probes with color-coded leads | PK400-3 Small gripper probe set for 0.008'' (0.2 mm) pin pitch, includes 10 probes with color-coded leads | MSO-MICTOR Mictor Cable, D0-D35 | MSO-3M 3M Interconnect Cable, D0-D17 or D18-D35 | Other Software Options | WPZi-XDEV Developer's Tool Kit Option for WavePro Zi Series | WPZi-SPECTRUM Spectrum Analyzer and Advanced FFT Option for WavePro Zi Series | WPZi-EMC EMC Pulse Parameter Software Package for WavePro Zi Series | Data Storage Software | WPZi-AORM Advanced Optical Recording Measurement Package for WavePro Zi Series | WPZi-DDM2 Disk Drive Measurements Software Package for WavePro Zi Series | Power Analysis Software | WPZi-PMA2 Power Measure Analysis Software Package | Digital Filtering Software | WPZi-DFP2 Digital Filter Software Package for WavePro Zi Series | Miscellaneous | KYBD-1 Keyboard | WPZi-HARDCASE Hard carrying case for all WavePro Zi Series oscilloscopes | WPZi-SOFTCASE Soft carrying case for all WavePro Zi Series oscilloscopes | RACKMOUNT-1 Rack-mount accessory for converting a WavePro Zi series oscilloscope to an 8U rack-mounted package | ZI-EXTDISP-15 Top-mounted, Fully Integrated 15.3" WXGA with Touch Screen Display, Including all Cabling and Software | TTL-AUX-OUT Accessory for Zi oscilloscopes to enable TTL level output from the Aux Out connector | Zi-FrontPanel-4Ch Removable front panel with 4 independent channel controls for WavePro 7Zi and WaveMaster 8Zi Oscilloscopes |
Current Probes | CP030 30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse | CP031 30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse | AP015 30 Amps, 50MHz BW Current Probe - AC/DC, 50 Amp Peak Pulse | CP150 150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse | CP500 500 Amps, 2 MHz BW Current Probe - AC/DC , 700 Amp Peak | DCS015 Deskew Calibration Source for AP015 | Differential Amplifiers | DA1855A DA1855A, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters | DXC100A DXC100A, Selectable ÷100 or ÷10 , Passive Differential Probe Pair for DA18xxA series | DXC200 ÷1,50 MHz low capacitance Passive Differential Probe Pair for DA18xxA series | DXC-5100 ÷100 2.5KV Passive High Voltage Probe Pair for DA18xxA series. Requires DA101 for full performance | DA101 ÷10 1MOhm Passive Attenuator for DXC series probes | DA1855A-PR2 2 Ch, 100 MHz Differential Amplifier with fast over drive recovery, calibrated offset, and selectable LP filters | DA1855A-PR2-RM Rack mountable version of the DA1855A-PR2 | DA1855A-RM DA1855A with rackmount | Differential Probes | D620 WaveLink 6 GHz Differential probe module 5V | D610 WaveLink 6 GHz Differential probe module 2.5V | D320 WaveLink 3.5 GHz Differential probe module 5V | AP034 1 GHz Active Differential Probe | D310 WaveLink 3.5 GHz Differential probe module 2.5V | D600A-AT WaveLink 7.5 GHz Differential Probe with Adjustable Tip Module | D500PT WaveLink 6 GHz Differential Positioner Mounted Tip Module | WL-Pbus WaveLink ProBus probe body = 3.5 GHz | AP033 500 MHz Active Differential Probe | High Voltage Probes | PPE1.2KV 10:1/100:1 200/300 MHz 5M Ohm/50M Ohm | PPE2KV 100:1 400 MHz 50M Ohm High Voltage Probe | PPE4KV 100:1 400 MHz 50M Ohm High-Voltage Probe | PPE5KV 100:1 400 MHz 50M Ohm High-Voltage Probe | PPE6KV 1000:1 400 MHz 50M Ohm High-Voltage Probe | PPE20KV 1000:1 100 MHz 100M Ohm High-Voltage Probe | High Voltage Differential Probes | AP031 15 MHz Differential Probe | ADP300 High-Voltage Active Differential Probe | ADP305 High-Voltage Differential Probes From LeCroy | Optical Probes | OE425 Short wavelength O/E Converter (500-870 nm) | OE455 Long wavelength O/E Converter (950-1630 nm) | OE525 Short wavelength O/E Converter (500-870 nm) | OE555 Long wavelength O/E converter | Probe Parts and Kits | LPA-SMA-KIT-A Kit of Pro-Link to SMA Adapter, new style | LPA-SMA-A Pro-Link to SMA Adapter, new style | D620-PT WaveLink D620 6 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D610-PT WaveLink D610 6 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D600ST WaveLink 7 GHz Differential Probe with Small Tip Module (includes D6000ST-SI, D600ST-QC, D600ST-SP) | D350ST WaveLink 4 GHz, 5 V Differential with Small Tip Module | D320-PT WaveLink D320 3.5 GHz/5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx20-PT Adjustable Positioner Tip. 4.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D310-PT WaveLink D310 3.5 GHz/2.5Vp-p and +/-3V Offset Range Differential Amplifier Small Tip Module with Dx10-PT Adjustable Positioner Tip. 2.8 mVrms (typical) probe + scope noise. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2). | D300A-AT WaveLink 4 GHz Differential Probe with Adjustable Tip Module | Transmission Line Probes | PP066 7.5 GHz Low Capacitance ÷10/÷20 probe |
|
|
|